Diagnosing Neonatal Aortic Coarctation in the Setting of Patent Ductus Arteriosus

被引:11
|
作者
Peng, David M.
Punn, Rajesh
Maeda, Katsuhide
Tierney, Elif Seda Selamet [1 ,2 ]
机构
[1] Stanford Univ, Lucile Packard Childrens Hosp, Div Pediat Cardiol, 725 Welch Rd,Ste 120, Palo Alto, CA 94304 USA
[2] Stanford Univ, Dept Pediat, 725 Welch Rd,Ste 120, Palo Alto, CA 94304 USA
来源
ANNALS OF THORACIC SURGERY | 2016年 / 101卷 / 03期
关键词
CONGENITAL HEART-DISEASE; NONINVASIVE DIAGNOSIS; PREVALENCE; VOLUME;
D O I
10.1016/j.athoracsur.2015.09.050
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. In neonates, it is challenging to diagnose aortic coarctation in the setting of a patent ductus arteriosus (PDA). Frequently, serial echocardiograms are performed, and diagnosis is delayed until the PDA closes. The purpose of this study was to identify echocardiographic predictors of neonatal coarctation in the presence of a PDA in cases in which diagnosis is uncertain. Methods. We retrospectively identified neonates diagnosed with possible but not definitive coarctation in the presence of a PDA by echocardiography (January 2004 through August 2013). The carotid-subclavian artery index (CSAi) was defined as the distal transverse arch diameter divided by the distance between the left common carotid and left subclavian arteries. Medical records were reviewed to identify patients who underwent coarctation repair within 1 year. A separate validation group was identified with the same methodology (September 2013 through April 2015). Results. Thirty-three patients were identified (median age 1, range 0-8 days). Twelve patients (36%) underwent coarctation repair. The coarctation group had smaller aortic and mitral valves, distal transverse arch, and isthmus z scores, larger right innominate artery, and longer transverse arch compared with the remaining group (p < 0.05). The CSAi was lower in the coarctation group (p = 0.014), and a cutoff of less than 0.85 yielded a sensitivity of 0.83 and specificity of 0.86 for coarctation (area under the receiver operating characteristic curve, 0.91). In the validation group (n = 12; median follow-up, 316 days), none of the 8 patients with a CSAi of greater than 0.85 have required surgery. The intraclass correlation coefficient for CSAi was 0.79 (95% confidence interval, 0.18 to 0.95). Conclusions. The CSAi, a simple and reproducible measure, can identify neonates at risk for aortic coarctation even in the presence of a PDA, prevent multiple echocardiographic evaluations, and hence guide appropriate resource utilization. (C) 2016 by The Society of Thoracic Surgeons
引用
收藏
页码:1005 / 1011
页数:8
相关论文
共 50 条
  • [21] Patent ductus arteriosus in Fetal Valproate Syndrome
    P. Anoop
    C. K. Sasidharan
    The Indian Journal of Pediatrics, 2003, 70 (8) : 681 - 682
  • [22] Minimally Invasive Patent Ductus Arteriosus Ligation
    Garcia, Alejandro V.
    Lukish, Jeffrey
    CLINICS IN PERINATOLOGY, 2017, 44 (04) : 763 - +
  • [23] Association of Patent Ductus Arteriosus with Tetralogy Of Fallot
    Koh, Angela S.
    Le Tan, Ju
    PROCEEDINGS OF SINGAPORE HEALTHCARE, 2010, 19 (03) : 271 - 272
  • [24] Two cases of patent ductus arteriosus in the dog
    Debevere, S.
    Vlerick, L.
    Bavegems, V.
    Binst, D.
    Cornillie, P.
    Polis, I.
    de Rooster, H.
    VLAAMS DIERGENEESKUNDIG TIJDSCHRIFT, 2014, 83 (01): : 28 - 35
  • [25] Interventional treatment of patent ductus arteriosus in 2004
    Moore, JW
    Levi, DS
    Moore, SD
    Schneider, DJ
    Berdjis, F
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2005, 64 (01) : 91 - 101
  • [26] Patent ductus arteriosus - not only a paediatric issue
    Jedrzejek, Michal
    Sarbinowska, Joanna
    Wislinska, Katarzyna
    Blaz, Witold
    PEDIATRIA I MEDYCYNA RODZINNA-PAEDIATRICS AND FAMILY MEDICINE, 2014, 10 (03): : 291 - 305
  • [27] Genetics of Patent Ductus Arteriosus Susceptibility and Treatment
    Hajj, Hanine
    Dagle, John M.
    SEMINARS IN PERINATOLOGY, 2012, 36 (02) : 98 - 104
  • [28] Interventional cardiac catheterization therapy for combined coarctation of the aorta and patent ductus arteriosus: Successful outcome in two infants
    Geggel, RL
    Hijazi, ZM
    Rhodes, J
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1996, 38 (01): : 67 - 70
  • [29] Does Treatment of Patent Ductus Arteriosus With Cyclooxygenase Inhibitors Affect Neonatal Regional Tissue Oxygenation?
    Bhatt, Mayoor
    Petrova, Anna
    Mehta, Rajeev
    PEDIATRIC CARDIOLOGY, 2012, 33 (08) : 1307 - 1314
  • [30] Congenital Atresia of the Left Main Coronary Artery Associated With Patent Ductus Arteriosus and Aortic Regurgitation
    Chou, Hsin-Hua
    Chan, Chih-Hsiang
    Tsai, Kuei-Ton
    Chang, Chung-I
    Ko, Yu-Lin
    CIRCULATION JOURNAL, 2009, 73 (06) : 1163 - 1166