Comparing dynamic and stationary standing postures in an assembly task

被引:86
作者
Balasubramanian, Venkatesh [1 ]
Adalarasu, K. [1 ]
Regulapati, Rahul [1 ]
机构
[1] Indian Inst Technol Madras, Dept Biotechnol, Rehabil Bioengn Grp, Madras 600036, Tamil Nadu, India
关键词
Work-related musculoskeletal disorders sEMG; Psychophysics; Standing postures; Manufacturing ergonomics; Occupational safety; MUSCULOSKELETAL DISORDERS; MUSCLE FATIGUE; CONDUCTION-VELOCITY; POWER FREQUENCY; WORK; EMG; EXERCISE; MANIFESTATIONS; CONTRACTIONS; SYMPTOMS;
D O I
10.1016/j.ergon.2008.10.017
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Prolonged standing during monotonous tasks such as assembly line jobs may lead to musculoskeletal disorders including increased fatigue, pain and stiffness in active muscles. This study evaluated the efficacy of a dynamic standing posture over the stationary standing posture in reducing physical stress using sEMG and psychophysical analysis. From the sEMG study, it was found that the fatigue rates in leg and lower back muscles were significantly higher (p < 0.05) in the stationary standing posture as compared to the dynamic standing posture. This finding was corroborated by the results of psychophysical test. Ergonomic design of the dynamic posture that has been proposed in this study can be easily absorbed into most shop-floors to decrease the incidence of musculoskeletal disorders. Relevance to Industry: The proposed dynamic standing can decrease fatigue and risk of acquiring lower extremity disorders than a stationary standing during shop-floor and assembly line duties. Dynamic standing is simple to implement and can be incorporated in existing assembly line. This can improve occupational safety by reducing work-related musculoskeletal disorders. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:649 / 654
页数:6
相关论文
共 47 条
[1]   Electromyogram median power frequency in dynamic exercise at medium exercise intensities [J].
Ament, W ;
Bonga, GJJ ;
Hof, AL ;
Verkerke, GJ .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1996, 74 (1-2) :180-186
[2]  
[Anonymous], 1997, MUSCULOSKELETAL DISO
[3]  
[Anonymous], 1985, Muscle alive: their functions revealed by electromyography
[4]   MUSCLE-FIBER CONDUCTION-VELOCITY, MEAN POWER FREQUENCY, MEAN EMG VOLTAGE AND FORCE DURING SUBMAXIMAL FATIGUING CONTRACTIONS OF HUMAN QUADRICEPS [J].
ARENDTNIELSEN, L ;
MILLS, KR .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 1988, 58 (1-2) :20-25
[5]  
Balasubramanian V., 2006, International Journal of Industrial and Systems Engineering, V1, P321, DOI 10.1504/IJISE.2006.009798
[6]  
BALASUBRAMANIAN V, 2001, 9995016 UMI AAT LOUI
[7]   EMG-based analysis of change in muscle activity during simulated driving [J].
Balasubramanian, Venkatesh ;
Adalarasu, K. .
JOURNAL OF BODYWORK AND MOVEMENT THERAPIES, 2007, 11 (02) :151-158
[8]   Reducing the costs of work-related musculoskeletal disorders: targeting strategies to chronic disability cases [J].
Baldwin, ML .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2004, 14 (01) :33-41
[9]  
Bethea D., 2002, DEV PRACTICAL HEAT S
[10]   Leg swelling, comfort and fatigue when sitting, standing, and sit/standing [J].
Chester, MR ;
Rys, MJ ;
Konz, SA .
INTERNATIONAL JOURNAL OF INDUSTRIAL ERGONOMICS, 2002, 29 (05) :289-296