A Novel Structural Similarity Based Pilot Protection for Renewable Power Transmission Line

被引:33
作者
Zheng, Liming [1 ]
Jia, Ke [2 ]
Bi, Tianshu [3 ]
Yang, Zhe [1 ]
Fang, Yu [1 ]
机构
[1] North China Elect Power Univ, Beijing 102206, Peoples R China
[2] North China Elect Power Univ, Elect & Elect Engn, Beijing 102206, Peoples R China
[3] North China Elect Power Univ, Sch Elect & Elect Engn, Beijing 102206, Peoples R China
基金
中国国家自然科学基金;
关键词
Renewable energy sources; Fault currents; Generators; Wavelet transforms; Circuit faults; Power generation; Wind farms; Pilot protection; structural similarity; square error; transmission line; renewable power plant; NETWORKS; TOPOLOGY;
D O I
10.1109/TPWRD.2020.2973505
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The wide application of power electronic component in power system with renewable energy sources has changed the fault characteristics of conventional power system, resulting in the performance degradation of conventional protection, and even the risk of maloperation and rejection. This brings challenges to the security and stability of the power grid. Therefore, in order to solve these problems, a novel principle of pilot protection based on structural similarity and square error method is proposed. The structural similarity criterion makes use of the difference of fault characteristics between renewable sources and synchronous generators to identify internal faults, while the square error auxiliary criterion is used to solve abnormal calculation of the existing similarity based protection. The detailed model of grid-connected renewable energy power plant is built in Real Time Digital Simulator (RTDS) and the proposed protection algorithm is solidified in the industrial protection device. The effectiveness of the proposed principle is verified by hardware-in-loop dynamic simulation experiments. Compared with conventional differential protection, the proposed protection shows excellent performance in speed and reliability during various faults. In addition, a field short-circuit test is carried out in a real wind farm to verify the effectiveness of the proposed protection scheme. It is proved that this proposed method has the prospect for industrial application.
引用
收藏
页码:2672 / 2681
页数:10
相关论文
共 50 条
  • [41] A Novel Principle of Line Pilot Protection Based on the Recognition of Phase Space Trajectory of Fault Component Instantaneous Power
    Jin N.
    Rong Z.
    Lin X.
    Xing J.
    Li Z.
    Liu S.
    Liu Y.
    Zhang P.
    Jing R.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2019, 39 (09): : 2702 - 2712
  • [42] A pilot protection scheme for flexible HVDC transmission lines based on modulus power
    Ma, Jing
    Xiao, Zhaohang
    Cheng, Peng
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2022, 137
  • [43] Pilot Protection for MMC-HVDC Transmission Line Based on Custom Difference Current
    Ning L.
    Tai N.
    Zheng X.
    Huang W.
    Zheng, Xiaodong (xiaodongzheng@sjtu.edu.cn), 1600, Automation of Electric Power Systems Press (41): : 87 - 93and133
  • [44] Singular Value Decomposition Based Pilot Protection for Transmission Lines With Converters on Both Ends
    Zheng, Liming
    Jia, Ke
    Yang, Bin
    Bi, Tianshu
    Yang, Qixun
    IEEE TRANSACTIONS ON POWER DELIVERY, 2022, 37 (04) : 2728 - 2737
  • [45] A Novel Pilot Protection for HVDC Transmission Lines Based on Model Error Function
    Li Dong
    Jin Xing-fu
    ADVANCED DESIGN AND MANUFACTURING TECHNOLOGY III, PTS 1-4, 2013, 397-400 : 1878 - +
  • [46] A Fast Directional Comparison Pilot Protection for UHV Transmission Line
    Ma, Yueyang
    Zou, Guibin
    Gao, Zhanjun
    Du, Tao
    2016 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2016, : 526 - 530
  • [47] Pilot protection of HVDC power transmission lines based on variation characteristics of firing angle
    Zhu X.
    Li H.
    Huang D.
    Wang G.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2020, 40 (06): : 163 - 169
  • [48] Phase-Space-Based Pilot Main Protection for a Transmission Line Immune to Timing Attack and Controllable Shunt Reactors
    Jin, Neng
    Lin, Xiangning
    Rong, Zirui
    Xing, Jiawei
    Chen, Le
    Li, Zhengtian
    Zhang, Peifu
    Tong, Ning
    Ma, Xiao
    IEEE TRANSACTIONS ON POWER DELIVERY, 2020, 35 (02) : 654 - 664
  • [49] A novel directional element for transmission line connecting inverter-interfaced renewable energy power plant
    Wang, Yuxi
    Wen, Minghao
    Chen, Yu
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2023, 145
  • [50] Pilot protection principle based on current model recognition applicable to transmission line with shunt reactors
    Shen, Quanyu
    Song, Guobing
    Suonan, Jiale
    Ma, Chao
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2014, 34 (01): : 109 - 114