Radial position sensing in a coplanar-grid high-pressure xenon gamma-ray spectrometer

被引:0
|
作者
Kiff, Scott D. [1 ]
He, Zhong [1 ]
Tepper, Gary C. [1 ]
机构
[1] Univ Michigan, Ann Arbor, MI 48109 USA
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper describes a technique for determining the interaction radius of a gamma ray within a cylindrical detector. This can be useful information for correcting pulse amplitudes and selecting events of interest. A theoretical expression for the event radius is derived based on anode signals, then simulations are compared with experimental results.
引用
收藏
页码:1196 / 1200
页数:5
相关论文
共 50 条
  • [21] High-pressure xenon ion chambers for gamma-ray spectroscopy in nuclear safeguards
    Beddingfield, DH
    Beyerle, A
    Russo, PA
    Ianakiev, K
    Vo, DT
    Dmitrenko, V
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 505 (1-2): : 474 - 477
  • [22] Vibrostability of high pressure xenon gamma-ray detectors
    Dmitrenko, V.V.
    Chernysheva, I.V.
    Gratchev, V.M.
    Kondakova, O.N.
    Krivova, K.V.
    Ulin, S.E.
    Uteshev, Z.M.
    Vlasik, K.F.
    IEEE Transactions on Nuclear Science, 2000, 47 (3 II) : 939 - 943
  • [23] DETERMINATION OF GAMMA-RAY POSITION USING A HIGH-PRESSURE FLASH TUBE CHAMBER
    BREARE, JM
    DOE, PJ
    ELDISOUKI, W
    NANDI, BC
    TAIT, ID
    NUCLEAR INSTRUMENTS & METHODS, 1977, 143 (01): : 49 - 55
  • [24] A portable gamma-ray spectrometer using compressed xenon
    Mahler, GJ
    Yu, B
    Smith, GC
    Kane, WR
    Lemley, JR
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) : 1029 - 1033
  • [25] Software tool for xenon gamma-ray spectrometer control
    Chernysheva, I. V.
    Novikov, A. S.
    Shustov, A. E.
    Dmitrenko, V. V.
    Nyein, Sone Pyae
    Petrenko, D.
    Ulin, S. E.
    Uteshev, Z. M.
    Vlasik, K. F.
    INTERNATIONAL CONFERENCE ON PARTICLE PHYSICS AND ASTROPHYSICS (ICPPA-2015), PTS 1-4, 2016, 675
  • [26] A portable gamma-ray spectrometer using compressed xenon
    Mahler, GJ
    Yu, B
    Smith, GC
    Kane, WR
    Lemley, JR
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 769 - 773
  • [27] Vibrostability of high pressure xenon gamma-ray detectors.
    Dmitrenko, VV
    Chernysheva, IV
    Gratchev, VM
    Kondakova, ON
    Krivova, KV
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 665 - 669
  • [28] Radiation stability of High Pressure Xenon gamma-ray spectrometers
    Dmitrenko, VV
    Dvornyak, AG
    Galper, AM
    Gratchev, VM
    Kondakova, ON
    Krivov, SV
    Krivova, KV
    Liagushin, VI
    Ulin, SE
    Uteshev, ZM
    Vlasik, KF
    Yurkin, YT
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 102 - 106
  • [29] Vibrostability of high pressure xenon gamma-ray detectors.
    Dmitrenko, VV
    Chernysheva, IV
    Gratchev, VM
    Kondakova, ON
    Krivova, KV
    Ulin, SE
    Uteshev, ZM
    Vlasik, KF
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (03) : 939 - 943
  • [30] Suitability of high-pressure xenon as scintillator for gamma ray spectroscopy
    Resnati, F.
    Gendotti, U.
    Chandra, R.
    Curioni, A.
    Davatz, G.
    Friederich, H.
    Gendotti, A.
    Goeltl, L.
    Jebali, R.
    Murer, D.
    Rubbia, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 715 : 87 - 91