Spectral optical coherence tomography - A novel technique for cornea imaging

被引:65
作者
Kaluzny, Bartlomiej J.
Kaluzny, Jakub J.
Szkulmowska, Anna
Gorczynska, Iwona
Szkulmowski, Maciej
Bajraszewski, Tomasz
Wojtkowski, Maciej
Targowski, Piotr
机构
[1] Nicholas Copernicus Univ, Collegium Medicum, Dept Ophthalmoimmunol, PL-85094 Bydgoszcz, Poland
[2] Nicholas Copernicus Univ, Inst Phys, PL-87100 Torun, Poland
关键词
spectral optical coherence tomography; cornea; imaging; CONFOCAL MICROSCOPY; ANTERIOR SEGMENT; PACHYMETRY; THICKNESS;
D O I
10.1097/01.ico.0000224644.81719.59
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Spectral optical coherence tomography (SOCT) is a new, noninvasive, noncontact, high-resolution technique that provides cross-sectional images of the objects that weakly absorb and scatter light. SOCT, because of very short acquisition time and high sensitivity, is capable of providing tomograms of substantially better quality than the conventional OCT. The aim of this paper is to show the application of the SOCT to cross-sectional imaging of the cornea and its pathologies. Methods: Eleven eyes with different corneal pathologies were examined with a slit lamp and the use of a prototype SOCT instrument constructed in the Institute of Physics, Nicolaus Copernicus University, Torun, Poland. Results: Our SOCT system provides high-resolution (4 mu m axial, 10 mu m transversal) tomograms composed of 3000-5000 A-scans with an acquisition time of 120-200 ms. The quality of the images is adequate for detailed cross-sectional evaluation of various corneal pathologies. Objective assessment of the localization, size, shape, and light-scattering properties of the changed tissue is possible. Corneal and epithelial thickness and the depth and width of lesions can be estimated. Conclusion: SOCT technique allows acquiring clinically valuable cross-sectional optical biopsy of the cornea and its pathologies.
引用
收藏
页码:960 / 965
页数:6
相关论文
共 26 条
  • [1] [Anonymous], Z1361 ANSI
  • [2] Central corneal thickness measurement with a retinal optical coherence tomography device versus standard ultrasonic pachymetry
    Bechmann, M
    Thiel, MJ
    Neubauer, AS
    Ullrich, S
    Ludwig, K
    Kenyon, KR
    Ulbig, MW
    [J]. CORNEA, 2001, 20 (01) : 50 - 54
  • [3] Specular microscopy, confocal microscopy, and ultrasound biomicroscopy - Diagnostic tools of the past quarter century
    Cavanagh, HD
    El-Agha, MS
    Petroll, WM
    Jester, JV
    [J]. CORNEA, 2000, 19 (05) : 712 - 722
  • [4] Investigation of dispersion effects in ocular media by multiple wavelength partial coherence interferometry
    Drexler, W
    Hitzenberger, CK
    Baumgartner, A
    Findl, O
    Sattmann, H
    Fercher, AF
    [J]. EXPERIMENTAL EYE RESEARCH, 1998, 66 (01) : 25 - 33
  • [5] Ultrahigh-resolution optical coherence tomography
    Drexler, W
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2004, 9 (01) : 47 - 74
  • [6] Assessment of central corneal thickness using optical coherence tomography
    Fishman, GR
    Pons, ME
    Seedor, JA
    Liebmann, JM
    Ritch, R
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (04) : 707 - 711
  • [7] Intraoperative 2-dimensional optical coherence tomography as a new tool for anterior segment surgery
    Geerling, G
    Müller, M
    Winter, C
    Hoerauf, H
    Oelckers, S
    Laqua, H
    Birngruber, R
    [J]. ARCHIVES OF OPHTHALMOLOGY, 2005, 123 (02) : 253 - 257
  • [8] Optical coherence tomography for the noninvasive evaluation of the cornea
    Hirano, K
    Ito, Y
    Suzuki, T
    Kojima, T
    Kachi, S
    Miyake, Y
    [J]. CORNEA, 2001, 20 (03) : 281 - 289
  • [9] HOLLADAY JT, 2005, CAT REF SURG TODAY S, V1, P1
  • [10] In vivo confocal microscopy of the human cornea
    Jalbert, I
    Stapleton, F
    Papas, E
    Sweeney, DF
    Coroneo, M
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2003, 87 (02) : 225 - 236