Ultra-performance liquid chromatography-tandem mass spectrometry:: A novel challenge in multiresidue pesticide analysis in food

被引:61
作者
Kovalczuk, Tomas [1 ]
Jech, Martin [1 ]
Poustka, Jan [1 ]
Hajslova, Jana [1 ]
机构
[1] Dept Food Chem & Anal, Inst Chem Technol, Prague 16628 6, Czech Republic
关键词
ultra-performance liquid chromatography; high-performance liquid chromatography; tandem quadrupole mass spectrometry; multiresidue; pesticides; food analysis;
D O I
10.1016/j.aca.2006.06.023
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Potential of ultra-performance liquid chromatography (UPLC) separation strategy coupled with tandem (in space) mass spectrometric detection (MS/MS) in multiresidue pesticide analysis was critically assessed. Performance parameters such as number of theoretical plates, height of theoretical plate, peak symmetry and peak capacity were measured/calculated on the basis of data generated by analysis of apple extracts containing 17 (semi)polar pesticides representing various classes of active ingredients of widely used crop protective preparations. Ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) procedure provided improved chromatographic parameters resulting in significantly increased sample throughput including lower solvent consumption and lower limits of quantitation (LOQs) for most of target analytes compared to common method employing conventional high-performance liquid chromatography (HPLC) separation. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:8 / 17
页数:10
相关论文
共 31 条
  • [1] *AG TECHN, 59891603EN AG TECHN
  • [2] *AG TECHN, 59886448EN AG TECHN
  • [3] Barnes KA, 1997, RAPID COMMUN MASS SP, V11, P117, DOI 10.1002/(SICI)1097-0231(19970115)11:1<117::AID-RCM781>3.0.CO
  • [4] 2-V
  • [5] Increasing throughput and information content for in vitro drug metabolism experiments using ultra-performance liquid chromatography coupled to a quadrupole time-of-flight mass spectrometer
    Castro-Perez, J
    Plumb, R
    Granger, JH
    Beattie, L
    Joncour, K
    Wright, A
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (06) : 843 - 848
  • [6] Effect of liquid chromatography separation of complex matrices on liquid chromatography-tandem mass spectrometry signal suppression
    Choi, BK
    Hercules, DM
    Gusev, AI
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2001, 907 (1-2) : 337 - 342
  • [7] Comparative study of test methods for reversed-phase columns for high-performance liquid chromatography
    Claessens, HA
    van Straten, MA
    Cramers, CA
    Jezierska, M
    Buszewski, B
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1998, 826 (02) : 135 - 156
  • [8] Reversed-phase liquid chromatographic separation of complex samples by optimizing temperature and gradient time I. Peak capacity limitations
    Dolan, JW
    Snyder, LR
    Djordjevic, NM
    Hill, DW
    Waeghe, TJ
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1999, 857 (1-2) : 1 - 20
  • [9] *EUR COMM, 2003, SANCO104762003 EUR C
  • [10] The high throughput analysis of N-methyl carbamate pesticides in wine and juice by electrospray ionization liquid chromatography tandem mass spectrometry with direct sample injection into a short column
    Goto, T
    Ito, Y
    Oka, H
    Saito, I
    Matsumoto, H
    Sugiyama, H
    Ohkubo, C
    Nakazawa, H
    Nagase, H
    [J]. ANALYTICA CHIMICA ACTA, 2005, 531 (01) : 79 - 86