Novel Stereoselective High-Performance Liquid Chromatographic Method for Simultaneous Determination of Guaifenesin and Ketorolac Enantiomers in Human Plasma

被引:12
|
作者
Maher, Hadir M. [1 ,2 ]
Al-Taweel, Shorog M. [1 ]
Alshehri, Mona M. [1 ]
Alzoman, Nourah Z. [1 ]
机构
[1] King Saud Univ, Coll Pharm, Dept Pharmaceut Chem, Riyadh 11495, Saudi Arabia
[2] Univ Alexandria, Fac Pharm, Dept Pharmaceut Analyt Chem, Alexandria, Egypt
关键词
chiral separation; amylose chiral selector; guaifenesin; ketorolac; human plasma; SEPARATION STRATEGY; CHIRAL SEPARATION; ANALGESIC POTENCY; STATIONARY PHASES; PARACETAMOL; HPLC; DRUGS; ENANTIOSEPARATION; PHARMACOKINETICS; MICROEXTRACTION;
D O I
10.1002/chir.22354
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
A novel method was developed for the simultaneous determination of guaifenesin (GUA) and ketorolac tromethamine (KET) enantiomers in plasma samples. Since GUA probably increases the absorption of coadministered drugs (e. g., KET), it would be extremely important to monitor KET plasma levels for the purpose of dose adjustment with a subsequent decrease in the side effects. Enantiomeric resolution was achieved on a polysaccharide-based chiral stationary phase, amylose-2, as a chiral selector under the normal phase (NP) mode and using ornidazole (ORN) as internal standard. This innovative method has the advantage of the ease and reliability of sample preparation for plasma samples. Sample clean-up was based on simply using methanol for protein precipitation followed by direct extraction of drug residues using ethanol. Both GUA and KET enantiomers were separated using an isocratic mobile phase composed of hexane/isopropanol/trifluoroacetic acid, 85: 15: 0.05 v/v/v. Peak area ratios were linear over the range 0.05-20 mu g/mL for the four enantiomers S (+) GUA, R (-) GUA, R (+) KET, and S (-) KET. The method was fully validated according to the International Conference on Harmonization (ICH) guidelines in terms of system suitability, specificity, accuracy, precision, robustness, and solution stability. Finally, this procedure was innovative to apply the rationale of developing a chiral high-performance liquid chromatography (HPLC) procedure for the simultaneous quantitative analysis of drug isomers in clinical samples. (C) 2014 Wiley Periodicals, Inc.
引用
收藏
页码:629 / 639
页数:11
相关论文
共 50 条
  • [31] A simple, sensitive and efficient assay for the determination of D- and L-lactic acid enantiomers in human plasma by high-performance liquid chromatography
    Cevasco, Giorgio
    Piatek, Anna Maria
    Scapolla, Carlo
    Thea, Sergio
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (06) : 787 - 792
  • [32] A simple high-performance liquid chromatographic method for the determination of acyclovir in human plasma and application to a pharmacokinetic study
    Yu, Liyan
    Xiang, Bingren
    Zhan, Ying
    ARZNEIMITTEL-FORSCHUNG-DRUG RESEARCH, 2008, 58 (04): : 199 - 202
  • [33] High performance liquid chromatographic assay for the simultaneous determination of midazolam and ketoconazole in plasma
    Hamdy, Dalia A.
    Brocks, Dion R.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2010, 53 (03) : 617 - 622
  • [35] High-performance liquid chromatographic method for the determination of moclobemide and its two major metabolites in human plasma
    Rakic, Anita
    Miljkovic, Branislava
    Pokrajac, Milena
    Vucicevic, Katarina
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (04) : 1416 - 1422
  • [36] Determination and validation of a simple high-performance liquid chromatographic method for simultaneous assay of iprodione and vinclozolin in human urine
    Carlucci, G
    Di Pasquale, D
    Ruggieri, F
    Mazzeo, P
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 828 (1-2): : 108 - 112
  • [37] Sensitive liquid chromatography-tandem mass spectrometry method for the simultaneous determination of paracetamol and guaifenesin in human plasma
    Chen, XY
    Huang, J
    Kong, Z
    Zhong, DF
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 817 (02): : 263 - 269
  • [38] Determination of celecoxib in human plasma and breast milk by high-performance liquid chromatographic assay
    Zhang, M
    Moore, GA
    Gardiner, SJ
    Begg, EJ
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 830 (02): : 245 - 248
  • [39] SIMULTANEOUS DETERMINATION OF DEXTRORPHAN AND GUAIFENESIN IN HUMAN PLASMA BY LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION
    STAVCHANSKY, S
    DEMIRBAS, S
    REYDERMAN, L
    CHAI, CK
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1995, 13 (07) : 919 - 925
  • [40] A simple high-performance liquid chromatographic method for the determination of diclofenac in human plasma: application to a comparative bioavailability study
    Rigato, H. M.
    Moreno, R. A.
    Orpinelli, E. Z.
    Borges, B. C.
    Sverdloff, C. E.
    Pedrazzoli, J., Jr.
    Borges, N. C.
    INTERNATIONAL JOURNAL OF CLINICAL PHARMACOLOGY AND THERAPEUTICS, 2009, 47 (02) : 132 - 140