Radiation detector based on 4H-SiC used for thermal neutron detection

被引:19
|
作者
Zatko, B. [1 ]
Sagatova, A. [2 ,3 ]
Sedlackova, K. [2 ]
Bohacek, P. [1 ]
Sekacova, M. [1 ]
Kohout, Z. [4 ]
Granja, C. [4 ]
Necas, V. [2 ]
机构
[1] Slovak Acad Sci, Inst Elect Engn, Dubravska Cesta 9, SK-84104 Bratislava, Slovakia
[2] Slovak Univ Technol Bratislava, Fac Elect Engn & Informat Technol, Ilkovicova 3, SK-81219 Bratislava, Slovakia
[3] Slovak Med Univ, Univ Ctr Elect Accelerators, Kukyselke 497, Trencin 91106, Slovakia
[4] Czech Tech Univ, Inst Expt & Appl Phys, Horska 3a-22, CZ-12800 Prague 2, Czech Republic
来源
JOURNAL OF INSTRUMENTATION | 2016年 / 11卷
关键词
Neutron detectors (cold thermal fast neutrons); Particle detectors; Simulation methods and programs; X-RAY-DETECTORS; SILICON-CARBIDE;
D O I
10.1088/1748-0221/11/11/C11022
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this work we have focused on detection of thermal neutrons generated by Pu-239-Be isotopic neutron source. A high quality liquid phase epitaxial layer of 4H-SiC was used as a detection region. The thickness of the layer was 70 mu m and the diameter of circular Au/Ni Schottky contact was 4.5 mm. Around the Schottky contact two guard rings were created. The detector structure was first examined as a detector of protons and alpha particles for energy calibration. Monoenergetic protons of energies from 300 keV up to 1.9 MeV were used for detector energy calibration and a good linearity was observed. The energy resolution of 35 keV was obtained for 1.9 MeV protons. The (LiF)-Li-6 conversion layer was applied on the detector Schottky contact. In the experiment we used different thicknesses of conversion layers from 5 mu m up to 35 mu m. Measured detected spectra show two parts corresponding to alpha particles detection in lower energy channels and H-3 in higher energy channels. We have also performed simulations of thermal neutron detection using MCNPX ( Monte Carlo N-particle eXtended) code. The detection efficiency and the detector response to thermal neutrons was calculated with respect to the (LiF)-Li-6 layer thickness. The detection efficiency calculation is found to be in good agreement with the experiment.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Neutron detection using epitaxial 4H-SiC detector structures
    Zat'ko, B.
    Sagatova, A.
    Sedlackova, K.
    Bohacek, P.
    Sekacova, M.
    Kovacova, E.
    Necas, V.
    2018 12TH INTERNATIONAL CONFERENCE ON ADVANCED SEMICONDUCTOR DEVICES AND MICROSYSTEMS (ASDAM), 2018, : 41 - 44
  • [2] Improvements in Realizing 4H-SiC Thermal Neutron Detectors
    Issa, F.
    Vervisch, V.
    Ottaviani, L.
    Szalkai, D.
    Vermeeren, L.
    Lyoussi, A.
    Kuznetsov, A.
    Lazar, M.
    Klix, A.
    Palais, O.
    Hallen, A.
    ISRD 15 - INTERNATIONAL SYMPOSIUM ON REACTOR DOSIMETRY, 2016, 106
  • [3] 4H-SiC Schottky Barrier Diodes for Efficient Thermal Neutron Detection
    Bernat, Robert
    Bakrac, Luka
    Radulovic, Vladimir
    Snoj, Luka
    Makino, Takahiro
    Ohshima, Takeshi
    Pastuovic, Zeljko
    Capan, Ivana
    MATERIALS, 2021, 14 (17)
  • [4] Detection of fast neutrons from D-T nuclear reaction using a 4H-SiC radiation detector
    Zatko, Bohumir
    Sagatova, Andrea
    Sedlackova, Katarina
    Necas, Vladimir
    Dubecky, Frantisek
    Solar, Michael
    Granja, Carlos
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON APPLICATIONS OF NUCLEAR TECHNIQUES (CRETE15), 2016, 44
  • [5] Fast Neutron Detection With 4H-SiC Based Diode Detector up to 500°C Ambient Temperature
    Szalkai, D.
    Ferone, R.
    Issa, F.
    Klix, A.
    Lazar, M.
    Lyoussi, A.
    Ottaviani, L.
    Tutto, P.
    Vervisch, V.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2016, 63 (03) : 1491 - 1498
  • [6] Neutron radiation effect on 4H-SiC MESFETs and SBDs
    Zhang Lin
    Zhang Yimen
    Zhang Yuming
    Han Chao
    JOURNAL OF SEMICONDUCTORS, 2010, 31 (11) : 1140061 - 1140064
  • [7] Study on 4H-SiC Trench Schottky-Type Neutron Detector
    Jiang, Wan-Chen
    Wang, Ying
    Hong, Bing
    Liu, Yun-Tao
    Zhang, Rui
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73
  • [8] Semiconductor detector based on 4H-SiC and analysis of its active region thickness
    Zat'ko, B.
    Sedlackova, K.
    Dubecky, F.
    Sagatova, A.
    Bohacek, P.
    Necas, V.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [9] 4H-SiC Neutron Sensors Based on Ion Implanted 10B Neutron Converter Layer
    Issa, Fatima
    Ottaviani, Laurent
    Szalkai, Dora
    Vermeeren, Lvermeer
    Vervisch, Vanessa
    Lyoussi, Abdallah
    Ferone, Raffaello
    Kuznetsov, Andrej
    Lazar, Mihai
    Klix, Axel
    Palais, Olivier
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2016, 63 (03) : 1976 - 1980
  • [10] 4H-SiC Neutron Sensors Based on Ion Implanted 10B Neutron Converter Layer
    Issa, F.
    Ottaviani, L.
    Szalkai, D.
    Vermeeren, L.
    Vervisch, V.
    Lyoussi, A.
    Feronc, R.
    Kuznetsov, A.
    Lazar, M.
    Klix, A.
    Palais, O.
    Hallen, A.
    2015 4TH INTERNATIONAL CONFERENCE ON ADVANCEMENTS IN NUCLEAR INSTRUMENTATION MEASUREMENT METHODS AND THEIR APPLICATIONS (ANIMMA), 2015,