Efficacy and Safety of Hair Removal with a Long-Pulsed Diode Laser Depending on the Spot Size: A Randomized, Evaluators-Blinded, Left-Right Study.

被引:13
作者
Jo, Seong Jin [1 ]
Kim, Jin Yong [1 ]
Ban, Juhee [2 ]
Lee, Youngjoo [2 ]
Kwon, Ohsang [1 ]
Koh, Wooseok [2 ]
机构
[1] Seoul Natl Univ, Coll Med, Dept Dermatol, Seoul, South Korea
[2] JMO Dermatol, Seoul 06035, South Korea
关键词
Hair; Hair removal; Long pulsed diode laser; Laser spot size; 800; NM; SELECTIVE PHOTOTHERMOLYSIS; LOW-FLUENCE; FOLLOW-UP; MULTICENTER; REDUCTION; DAMAGE; SKIN;
D O I
10.5021/ad.2015.27.5.517
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Background: The efficacy of the long-pulsed diode laser,(LPDL) in hair removal is determined with various physical parameters. Recently, LPDLs with a larger spot size are commercially available; however, the independent effect of spot size on hair removal has not been studied. Objective:This study aimed to compare the efficacy of the LPDL in hair removal depending on the spot size. Methods: A randomized, evaluators-blind, intrapatient comparison (left vs. right) trial was designed. Ten healthy Korean women received three hair removal treatment sessions on both armpits with the 805-nm LPDL and followed for 3 months. A 10 x 10 mm handpiece (D1) or a 10 x 30 mm handpiece (D3) was randomly assigned to the right or left axilla. The fluence, pulse duration, and epidermal cooling temperature were identical for both armpits. Hair clearance was quantified with high-resolution photos taken at each visit. Postprocedural pain was quantified on a visual analogue scale. Adverse events were evaluated by physical examination and the patients' self-report. Results: The mean hair clearance at 3 months after three treatment sessions was 38.7% and 50.1% on the armpits treated with D1 and D3, respectively (p = 0.028). Procedural pain was significantly greater in the side treated with D3 (p = 0.009). Serious adverse events were not observed. Conclusion: Given that the pulse duration, fluence, and epidermal cooling were identical, the 805-nm LPDL at the three times larger spot size showed an efficacy improvement of 29.5% in axillary hair removal without serious adverse events.
引用
收藏
页码:517 / 522
页数:6
相关论文
共 22 条
[1]   Extended theory of selective photothermolysis [J].
Altshuler, GB ;
Anderson, RR ;
Manstein, D ;
Zenzie, HH ;
Smirnov, MZ .
LASERS IN SURGERY AND MEDICINE, 2001, 29 (05) :416-432
[2]   SELECTIVE PHOTOTHERMOLYSIS - PRECISE MICROSURGERY BY SELECTIVE ABSORPTION OF PULSED RADIATION [J].
ANDERSON, RR ;
PARRISH, JA .
SCIENCE, 1983, 220 (4596) :524-527
[3]   Hair reduction using a scanning 800 nm diode laser [J].
Baugh, WP ;
Trafeli, JP ;
Barnette, DJ ;
Ross, EV .
DERMATOLOGIC SURGERY, 2001, 27 (04) :358-364
[4]   The effect of different spot sizes on the efficacy of hair removal using a long-pulsed diode laser [J].
Bäumler, W ;
Scherer, K ;
Abels, C ;
Neff, S ;
Landthaler, MI ;
Szeimies, RM .
DERMATOLOGIC SURGERY, 2002, 28 (02) :118-121
[5]   Hair removal with an 800-nm pulsed diode laser [J].
Campos, VB ;
Dierickx, CC ;
Farinelli, WA ;
Lin, TYD ;
Manuskiatti, W ;
Anderson, RR .
JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 2000, 43 (03) :442-447
[6]   An in vivo study comparing the efficacy and complications of diode laser and long-pulsed Nd:YAG laser in hair removal in Chinese patients [J].
Chan, HH ;
Ying, SY ;
Ho, WS ;
Wong, DSY ;
Lam, LK .
DERMATOLOGIC SURGERY, 2001, 27 (11) :950-954
[7]   Topical anesthesia for laser hair removal: Comparison of spot sizes and 755 nm versus 800 nm wavelengths [J].
Eremia, S ;
Newman, N .
DERMATOLOGIC SURGERY, 2000, 26 (07) :667-669
[8]   Comparative evaluation of different hair removal lasers in skin types IV, V, and VI [J].
Galadari, I .
INTERNATIONAL JOURNAL OF DERMATOLOGY, 2003, 42 (01) :68-70
[9]   Laser Hair Removal: A Review [J].
Gan, Stephanie D. ;
Graber, Emmy M. .
DERMATOLOGIC SURGERY, 2013, 39 (06) :823-838
[10]   Damage to hair follicles by normal-mode ruby laser pulses [J].
Grossman, MC ;
Dierickx, C ;
Farinelli, W ;
Flotte, T ;
Anderson, RR .
JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 1996, 35 (06) :889-894