Efficacy and Safety of Hair Removal with a Long-Pulsed Diode Laser Depending on the Spot Size: A Randomized, Evaluators-Blinded, Left-Right Study.

被引:13
作者
Jo, Seong Jin [1 ]
Kim, Jin Yong [1 ]
Ban, Juhee [2 ]
Lee, Youngjoo [2 ]
Kwon, Ohsang [1 ]
Koh, Wooseok [2 ]
机构
[1] Seoul Natl Univ, Coll Med, Dept Dermatol, Seoul, South Korea
[2] JMO Dermatol, Seoul 06035, South Korea
关键词
Hair; Hair removal; Long pulsed diode laser; Laser spot size; 800; NM; SELECTIVE PHOTOTHERMOLYSIS; LOW-FLUENCE; FOLLOW-UP; MULTICENTER; REDUCTION; DAMAGE; SKIN;
D O I
10.5021/ad.2015.27.5.517
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Background: The efficacy of the long-pulsed diode laser,(LPDL) in hair removal is determined with various physical parameters. Recently, LPDLs with a larger spot size are commercially available; however, the independent effect of spot size on hair removal has not been studied. Objective:This study aimed to compare the efficacy of the LPDL in hair removal depending on the spot size. Methods: A randomized, evaluators-blind, intrapatient comparison (left vs. right) trial was designed. Ten healthy Korean women received three hair removal treatment sessions on both armpits with the 805-nm LPDL and followed for 3 months. A 10 x 10 mm handpiece (D1) or a 10 x 30 mm handpiece (D3) was randomly assigned to the right or left axilla. The fluence, pulse duration, and epidermal cooling temperature were identical for both armpits. Hair clearance was quantified with high-resolution photos taken at each visit. Postprocedural pain was quantified on a visual analogue scale. Adverse events were evaluated by physical examination and the patients' self-report. Results: The mean hair clearance at 3 months after three treatment sessions was 38.7% and 50.1% on the armpits treated with D1 and D3, respectively (p = 0.028). Procedural pain was significantly greater in the side treated with D3 (p = 0.009). Serious adverse events were not observed. Conclusion: Given that the pulse duration, fluence, and epidermal cooling were identical, the 805-nm LPDL at the three times larger spot size showed an efficacy improvement of 29.5% in axillary hair removal without serious adverse events.
引用
收藏
页码:517 / 522
页数:6
相关论文
共 22 条
  • [1] Extended theory of selective photothermolysis
    Altshuler, GB
    Anderson, RR
    Manstein, D
    Zenzie, HH
    Smirnov, MZ
    [J]. LASERS IN SURGERY AND MEDICINE, 2001, 29 (05) : 416 - 432
  • [2] SELECTIVE PHOTOTHERMOLYSIS - PRECISE MICROSURGERY BY SELECTIVE ABSORPTION OF PULSED RADIATION
    ANDERSON, RR
    PARRISH, JA
    [J]. SCIENCE, 1983, 220 (4596) : 524 - 527
  • [3] Hair reduction using a scanning 800 nm diode laser
    Baugh, WP
    Trafeli, JP
    Barnette, DJ
    Ross, EV
    [J]. DERMATOLOGIC SURGERY, 2001, 27 (04) : 358 - 364
  • [4] The effect of different spot sizes on the efficacy of hair removal using a long-pulsed diode laser
    Bäumler, W
    Scherer, K
    Abels, C
    Neff, S
    Landthaler, MI
    Szeimies, RM
    [J]. DERMATOLOGIC SURGERY, 2002, 28 (02) : 118 - 121
  • [5] Hair removal with an 800-nm pulsed diode laser
    Campos, VB
    Dierickx, CC
    Farinelli, WA
    Lin, TYD
    Manuskiatti, W
    Anderson, RR
    [J]. JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 2000, 43 (03) : 442 - 447
  • [6] An in vivo study comparing the efficacy and complications of diode laser and long-pulsed Nd:YAG laser in hair removal in Chinese patients
    Chan, HH
    Ying, SY
    Ho, WS
    Wong, DSY
    Lam, LK
    [J]. DERMATOLOGIC SURGERY, 2001, 27 (11) : 950 - 954
  • [7] Topical anesthesia for laser hair removal: Comparison of spot sizes and 755 nm versus 800 nm wavelengths
    Eremia, S
    Newman, N
    [J]. DERMATOLOGIC SURGERY, 2000, 26 (07) : 667 - 669
  • [8] Comparative evaluation of different hair removal lasers in skin types IV, V, and VI
    Galadari, I
    [J]. INTERNATIONAL JOURNAL OF DERMATOLOGY, 2003, 42 (01) : 68 - 70
  • [9] Laser Hair Removal: A Review
    Gan, Stephanie D.
    Graber, Emmy M.
    [J]. DERMATOLOGIC SURGERY, 2013, 39 (06) : 823 - 838
  • [10] Damage to hair follicles by normal-mode ruby laser pulses
    Grossman, MC
    Dierickx, C
    Farinelli, W
    Flotte, T
    Anderson, RR
    [J]. JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 1996, 35 (06) : 889 - 894