Evaluation of a Novel Cone Beam Computed Tomography Scanner for Bone Density Examinations in Preoperative 3D Reconstructions and Correlation with Primary Implant Stability

被引:42
|
作者
Sennerby, Lars [1 ,2 ]
Andersson, Peter [2 ]
Pagliani, Luca
Giani, Claudio [3 ]
Moretti, Giacomo [4 ]
Molinari, Massimo [3 ]
Motroni, Alessandro [4 ]
机构
[1] Univ Gothenburg, Dept Oral & Maxillofacial Surg, Inst Odontol, SE-40530 Gothenburg, Sweden
[2] Clin Feltre, Feltre, Italy
[3] de Gotzen Srl, Olgiate Olona, Italy
[4] 3Diemme Srl, Cantu, Italy
关键词
bone density; CBCT; clinical study; implant stability; insertion torque; resonance frequency; RESONANCE FREQUENCY-ANALYSIS; TORQUE; INSERTION; QUALITY;
D O I
10.1111/cid.12193
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
BackgroundBone density examination (BDE) using preoperative cone beam computed tomography (CBCT) might be used to predict primary implant stability in implant patients. PurposeThe aim of the study was to validate a novel CBCT scanner in vitro with regard to BDE in preoperative scans and to analyze the in vivo correlation of CBCT scan results with primary implant stability measurements. Materials and MethodsA CBCT scanner was validated in vitro with regard to spatial uniformity and linearity of CT numbers (Hounsfield units, HU) by using a series of phantoms and plastic and hydroxyapatite specimens of various densities. Forty-nine patients (27 female and 22 male, mean age 55.69.8) were scanned prior to and 1 to 6 months after the placement of 155 dental implants of different lengths and diameters. Mean and peak insertion torque (IT) in Ncm were registered during implant placement. Resonance frequency analysis (RFA) measurements in ISQ units were performed after placement. The second scan was used to export and superimpose the exact positions of bone and implants into the first scan. Virtual probes with the same length as the actual implant were automatically placed at the implant sites, and mean HU values were measured in a 1mm-wide circular corridor from the tip of the threads and out. ResultsThe in vitro validation showed high uniformity and linearity of CT numbers (HU). The clinical study showed significant correlations between bone density and ISQ, mean IT, and peak IT, respectively. ConclusionsThe WhiteFox CBCT scanner measures bone density with high accuracy. There is a correlation between bone density and primary implant stability as assessed with IT and RFA measurements. The findings suggest that BDE may be used as an additional feature in treatment-planning software to estimate primary stability at predetermined implant sites.
引用
收藏
页码:844 / 853
页数:10
相关论文
共 50 条
  • [41] A comparative evaluation of Cone Beam Computed Tomography (CBCT) and Multi-Slice CT (MSCT). Part II: On 3D model accuracy
    Liang, Xin
    Lambrichts, Ivo
    Sun, Yi
    Denis, Kathleen
    Hassan, Bassam
    Li, Limin
    Pauwels, Ruben
    Jacobs, Reinhilde
    EUROPEAN JOURNAL OF RADIOLOGY, 2010, 75 (02) : 270 - 274
  • [43] Trabecular bone structure parameters from 3D image processing of clinical multi-slice and cone-beam computed tomography data
    Klintstrom, Eva
    Smedby, Orjan
    Moreno, Rodrigo
    Brismar, Torkel B.
    SKELETAL RADIOLOGY, 2014, 43 (02) : 197 - 204
  • [44] Accuracy Assessment of EM3D App-Based 3D Facial Scanning Compared to Cone Beam Computed Tomography
    Barone, Selene
    Antonelli, Alessandro
    Salviati, Marianna
    Greco, Vincenzo
    Bennardo, Francesco
    Becker, Kathrin
    Giudice, Amerigo
    Simeone, Michele
    DENTISTRY JOURNAL, 2024, 12 (11)
  • [45] 3D reconstruction images of cone beam computed tomography applied to maxillofacial fractures: A case study and mini review
    Bai, Liyun
    Li, Linlin
    Su, Kexin
    Bleyer, Anthony
    Zhang, Yuanyuan
    Ji, Ping
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2018, 26 (01) : 115 - 123
  • [46] The influence of the segmentation process on 3D measurements from cone beam computed tomography-derived surface models
    Engelbrecht, Willem P.
    Fourie, Zacharias
    Damstra, Janalt
    Gerrits, Peter O.
    Ren, Yijin
    CLINICAL ORAL INVESTIGATIONS, 2013, 17 (08) : 1919 - 1927
  • [47] Detectability of hepatic tumors during 3D post-processed ultrafast cone-beam computed tomography
    Paul, Jijo
    Vogl, Thomas J.
    Chacko, Annamma
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (20) : 8109 - 8127
  • [48] Three-dimensional evaluation of human jaw bone microarchitecture: correlation between the microarchitectural parameters of cone beam computed tomography and micro-computer tomography
    Kim, Jo-Eun
    Yi, Won-Jin
    Heo, Min-Suk
    Lee, Sam-Sun
    Choi, Soon-Chul
    Huh, Kyung-Hoe
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2015, 120 (06): : 762 - 770
  • [49] Accuracy evaluation of cone beam computed tomography applied to measure peri-implant bone thickness in living patients: an ex vivo and in vivo experiment
    Lan, Yanhua
    Huang, Xiaoyuan
    Fan, Mingxing
    Yu, Huazhen
    Xie, Zhijian
    Zhou, Yiqun
    CLINICAL ORAL INVESTIGATIONS, 2022, 26 (10) : 6347 - 6359
  • [50] 3D cone beam computed tomography reconstruction images in diagnosis of ameloblastomas of lower jaw: A case report and mini review
    Li, Dize
    Yang, Zhiqiang
    Chen, Tao
    Guan, Chao
    Wang, Feilong
    Matz, Ethan L.
    Zhang, Yuanyuan
    Ji, Ping
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2018, 26 (01) : 133 - 140