Evaluation of a Novel Cone Beam Computed Tomography Scanner for Bone Density Examinations in Preoperative 3D Reconstructions and Correlation with Primary Implant Stability

被引:42
|
作者
Sennerby, Lars [1 ,2 ]
Andersson, Peter [2 ]
Pagliani, Luca
Giani, Claudio [3 ]
Moretti, Giacomo [4 ]
Molinari, Massimo [3 ]
Motroni, Alessandro [4 ]
机构
[1] Univ Gothenburg, Dept Oral & Maxillofacial Surg, Inst Odontol, SE-40530 Gothenburg, Sweden
[2] Clin Feltre, Feltre, Italy
[3] de Gotzen Srl, Olgiate Olona, Italy
[4] 3Diemme Srl, Cantu, Italy
关键词
bone density; CBCT; clinical study; implant stability; insertion torque; resonance frequency; RESONANCE FREQUENCY-ANALYSIS; TORQUE; INSERTION; QUALITY;
D O I
10.1111/cid.12193
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
BackgroundBone density examination (BDE) using preoperative cone beam computed tomography (CBCT) might be used to predict primary implant stability in implant patients. PurposeThe aim of the study was to validate a novel CBCT scanner in vitro with regard to BDE in preoperative scans and to analyze the in vivo correlation of CBCT scan results with primary implant stability measurements. Materials and MethodsA CBCT scanner was validated in vitro with regard to spatial uniformity and linearity of CT numbers (Hounsfield units, HU) by using a series of phantoms and plastic and hydroxyapatite specimens of various densities. Forty-nine patients (27 female and 22 male, mean age 55.69.8) were scanned prior to and 1 to 6 months after the placement of 155 dental implants of different lengths and diameters. Mean and peak insertion torque (IT) in Ncm were registered during implant placement. Resonance frequency analysis (RFA) measurements in ISQ units were performed after placement. The second scan was used to export and superimpose the exact positions of bone and implants into the first scan. Virtual probes with the same length as the actual implant were automatically placed at the implant sites, and mean HU values were measured in a 1mm-wide circular corridor from the tip of the threads and out. ResultsThe in vitro validation showed high uniformity and linearity of CT numbers (HU). The clinical study showed significant correlations between bone density and ISQ, mean IT, and peak IT, respectively. ConclusionsThe WhiteFox CBCT scanner measures bone density with high accuracy. There is a correlation between bone density and primary implant stability as assessed with IT and RFA measurements. The findings suggest that BDE may be used as an additional feature in treatment-planning software to estimate primary stability at predetermined implant sites.
引用
收藏
页码:844 / 853
页数:10
相关论文
共 50 条
  • [31] Gray value measurement for the evaluation of local alveolar bone density around impacted maxillary canine teeth using cone beam computed tomography
    Secgin, Cansu Koseoglu
    Karslioglu, Hazal
    Ozemre, Mehmet Ozgur
    Orhan, Kaan
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2021, 26 (05): : E669 - E675
  • [32] The reliability of cone-beam computed tomography to assess bone density at dental implant recipient sites: a histomorphometric analysis by micro-CT
    Gonzalez-Garcia, Raul
    Monje, Florencio
    CLINICAL ORAL IMPLANTS RESEARCH, 2013, 24 (08) : 871 - 879
  • [33] Can the Density of Mineralized Dental Tissues (Dentin and Enamel) Be Measured and Compared with 3D Cone Beam Computed Tomography in Cases of Ectodermal Dysplasia?
    Yavuz, Yasemin
    Akleyin, Ebru
    Dogan, Mehmet Sinan
    Goncharuk-Khomyn, Myroslav
    Akkus, Zeki
    MEDICAL SCIENCE MONITOR, 2022, 28
  • [34] Does Cone Beam Computed Tomography-Derived Bone Density Give Predictable Data About Stability Changes of Immediately Loaded Implants?: A 1-Year Resonance Frequency Follow-up Study
    Tatli, Ufuk
    Salimov, Fariz
    Kurkcu, Mehmet
    Akoglan, Mucahide
    Kurtoglu, Cem
    JOURNAL OF CRANIOFACIAL SURGERY, 2014, 25 (03) : E293 - E299
  • [35] A new 3D method for measuring cranio-facial relationships with cone beam computed tomography (CBCT)
    Zamora, Natalia
    Cibrian, Rosa
    Gandia, Jose-Luis
    Paredes, Vanessa
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2013, 18 (04): : E706 - E713
  • [36] Life in 3D: A 10 year review of literature on the application of cone beam computed tomography in dental implantology
    Uzbek, Usman
    Ab Rahman, Saifulizan
    Hindi, Rafi Mahmud
    Gillani, Syed Wasif
    Athar, Yousaf
    HEALTHMED, 2012, 6 (05): : 1754 - 1762
  • [37] Quantitative Comparison of Cone Beam Computed Tomography and Microradiography in the Evaluation of Bone Density after Maxillary Sinus Augmentation: A Preliminary Study
    Soardi, Carlo M.
    Zaffe, Davide
    Motroni, Alessandro
    Wang, Hom-Lay
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2014, 16 (04) : 557 - 564
  • [38] The Role of Cone Beam Computed Tomography in Periodontology: From 3D Models of Periodontal Defects to 3D-Printed Scaffolds
    Verykokou, Styliani
    Ioannidis, Charalabos
    Soile, Sofia
    Angelopoulos, Christos
    Theodoridis, Konstantinos
    Arampatzis, Athanasios S.
    Assimopoulou, Andreana N.
    Christofilos, Dimitrios
    Kapourani, Afroditi
    Pantazos, Ioannis
    Barmpalexis, Panagiotis
    Boutsi, Argyro-Maria
    Potsiou, Chryssy
    JOURNAL OF PERSONALIZED MEDICINE, 2024, 14 (02):
  • [39] Morphofunctional evaluation of buccopharyngeal space using three-dimensional cone-beam computed tomography (3D-CBCT)
    Hinganu, Marius Valeriu
    Hinganu, Delia
    Cozma, Sebastian Romica
    Asimionoaiei-Simionescu, Cristina
    Scutariu, Irina Andreea
    Ionesi, Dorin Savin
    Haba, Danisia
    ANNALS OF ANATOMY-ANATOMISCHER ANZEIGER, 2018, 220 : 1 - 8
  • [40] Influence of object location in cone beam computed tomography (NewTom 5G and 3D Accuitomo 170) on gray value measurements at an implant site
    Azin Parsa
    Norliza Ibrahim
    Bassam Hassan
    Paul van der Stelt
    Daniel Wismeijer
    Oral Radiology, 2014, 30 : 153 - 159