Evaluation of a Novel Cone Beam Computed Tomography Scanner for Bone Density Examinations in Preoperative 3D Reconstructions and Correlation with Primary Implant Stability

被引:42
|
作者
Sennerby, Lars [1 ,2 ]
Andersson, Peter [2 ]
Pagliani, Luca
Giani, Claudio [3 ]
Moretti, Giacomo [4 ]
Molinari, Massimo [3 ]
Motroni, Alessandro [4 ]
机构
[1] Univ Gothenburg, Dept Oral & Maxillofacial Surg, Inst Odontol, SE-40530 Gothenburg, Sweden
[2] Clin Feltre, Feltre, Italy
[3] de Gotzen Srl, Olgiate Olona, Italy
[4] 3Diemme Srl, Cantu, Italy
关键词
bone density; CBCT; clinical study; implant stability; insertion torque; resonance frequency; RESONANCE FREQUENCY-ANALYSIS; TORQUE; INSERTION; QUALITY;
D O I
10.1111/cid.12193
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
BackgroundBone density examination (BDE) using preoperative cone beam computed tomography (CBCT) might be used to predict primary implant stability in implant patients. PurposeThe aim of the study was to validate a novel CBCT scanner in vitro with regard to BDE in preoperative scans and to analyze the in vivo correlation of CBCT scan results with primary implant stability measurements. Materials and MethodsA CBCT scanner was validated in vitro with regard to spatial uniformity and linearity of CT numbers (Hounsfield units, HU) by using a series of phantoms and plastic and hydroxyapatite specimens of various densities. Forty-nine patients (27 female and 22 male, mean age 55.69.8) were scanned prior to and 1 to 6 months after the placement of 155 dental implants of different lengths and diameters. Mean and peak insertion torque (IT) in Ncm were registered during implant placement. Resonance frequency analysis (RFA) measurements in ISQ units were performed after placement. The second scan was used to export and superimpose the exact positions of bone and implants into the first scan. Virtual probes with the same length as the actual implant were automatically placed at the implant sites, and mean HU values were measured in a 1mm-wide circular corridor from the tip of the threads and out. ResultsThe in vitro validation showed high uniformity and linearity of CT numbers (HU). The clinical study showed significant correlations between bone density and ISQ, mean IT, and peak IT, respectively. ConclusionsThe WhiteFox CBCT scanner measures bone density with high accuracy. There is a correlation between bone density and primary implant stability as assessed with IT and RFA measurements. The findings suggest that BDE may be used as an additional feature in treatment-planning software to estimate primary stability at predetermined implant sites.
引用
收藏
页码:844 / 853
页数:10
相关论文
共 50 条
  • [1] The Effect of Bone Density Measured by Cone Beam Computed Tomography and Implant Dimensions on the Stability of Dental Implants
    Noaman, Ali Tareef
    Bede, Salwan Y.
    JOURNAL OF CRANIOFACIAL SURGERY, 2022, 33 (06) : E553 - E557
  • [2] Evaluation of relationship between preoperative bone density values derived from cone beam computed tomography and implant stability parameters: a clinical study
    Salimov, Fariz
    Tatli, Ufuk
    Kurkcu, Mehmet
    Akoglan, Mucahide
    Oztunc, Haluk
    Kurtoglu, Cem
    CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (09) : 1016 - 1021
  • [3] Assessments of jaw bone density at implant sites using 3D cone-beam computed tomography
    Hao, Y.
    Zhao, W.
    Wang, Y.
    Yu, J.
    Zou, D.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2014, 18 (09) : 1398 - 1403
  • [4] Relationship between the bone density estimated by cone-beam computed tomography and the primary stability of dental implants
    Isoda, Kei
    Ayukawa, Yasunori
    Tsukiyama, Yoshihiro
    Sogo, Motofumi
    Matsushita, Yasuyuki
    Koyano, Kiyoshi
    CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (07) : 832 - 836
  • [5] Correlation Between Bone Quality Evaluated by Cone-Beam Computerized Tomography and Implant Primary Stability
    Song, Young-Dai
    Jun, Sang-Ho
    Kwon, Jong-Jin
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2009, 24 (01) : 59 - 64
  • [6] The Accuracy of Cone-Beam Computed Tomography for Evaluating Bone Density and Cortical Bone Thickness at the Implant Site: Micro-Computed Tomography and Histologic Analysis
    Suttapreyasri, Srisurang
    Suapear, Pradipat
    Leepong, Narit
    JOURNAL OF CRANIOFACIAL SURGERY, 2018, 29 (08) : 2026 - 2031
  • [7] The relationship between dental implant stability and trabecular bone structure using cone-beam computed tomography
    Kang, Se-Ryong
    Bok, Sung-Chul
    Choi, Soon-Chul
    Lee, Sam-Sun
    Heo, Min-Suk
    Huh, Kyung-Hoe
    Kim, Tae-Il
    Yi, Won-Jin
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2016, 46 (02) : 116 - 127
  • [8] The evaluation of palatal bone thickness for implant insertion with cone beam computed tomography
    Sumer, A. P.
    Caliskan, A.
    Uzun, C.
    Karoz, T. B.
    Sumer, M.
    Cankaya, S.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2016, 45 (02) : 216 - 220
  • [9] Accuracy and reproducibility of four cone beam computed tomography devices using 3D implant-planning software
    Stimmelmayr, M.
    Denk, K.
    Erdelt, K.
    Krennmair, G.
    Mansour, S.
    Beuer, F.
    Guethg, J-F.
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2017, 20 (01) : 21 - 34
  • [10] Primary Stability Evaluation of a Novel Tapered Implant Inserted in Low-Density Bone Sites: An In Vitro Study
    Degidi, Marco
    Daprile, Giuseppe
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2023, 38 (02) : 334 - 337