Parametric study of heat transfer characteristics of enhanced surfaces in a spray cooling system: An experimental investigation

被引:36
作者
Salman, Azzam S. [1 ,2 ]
Abdulrazzaq, Nabeel M. [1 ]
Tikadar, Amitav [3 ]
Oudah, Saad K. [1 ]
Khan, Jamil A. [1 ]
机构
[1] Univ South Carolina, Dept Mech Engn, Columbia, SC 29208 USA
[2] Minist Oil, Dept Qaiyarah Refinery, North Refineries Co, Mosul 41008, NI, Iraq
[3] Georgia Inst Technol, George W Woodruff Sch Mech Engn, Atlanta, GA 30332 USA
关键词
Spray cooling; Enhanced surfaces; Nozzle-to-surface distance; Effective heat flux; Effective heat transfer coefficient; Heat transfer enhancement ratio; Heat transfer characteristics; TRANSFER PERFORMANCE; STRUCTURED SURFACES; WATER; IMPACT; DROP;
D O I
10.1016/j.applthermaleng.2020.115824
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper, a series of experiments were conducted to investigate the influences of nozzle-to-surface distance, coolant volumetric flow rate, and temperature difference between the target surface and coolant inlet temperatures, on the heat transfer characteristics of enhanced surfaces in a spray cooling system. Three different structures of macro circular and radial grooves, having depth and width of 500 x 500 mu m, respectively, were machined directly on the top of a 15 mm copper surface. Surfaces were enhanced with four circular grooves (M1), a combination of four circular and four radial grooves (M2), and a combination of four circular and eight radial grooves (M3), to increase the wetted surface area and disturb both thermal and hydraulic boundary layers. These surfaces were tested in a closed-loop spray cooling system, utilizing deionized (DI) water as a coolant, at nozzle-to-surface distances, temperature differences, and volumetric flow rates ranging between 8-12 mm, 5-75 K, and 115-180 mL/min, respectively. During all experiments, both chamber pressure and coolant inlet temperature were maintained approximately constant at atmospheric pressure and 295 K, respectively. The results illustrate that radial grooves and surface structures play a more important role than spray coverage area and surface wetted area in the thermal performance of a surface because radial grooves increase the fluid velocity and decrease the fluid film thickness over the target surface and eventually reduce the convective thermal resistance. Furthermore, it was observed that M3 has the highest heat transfer enhancement ratio, followed by M2 and Ml, at all experimental conditions, due to the reduction in the convective thermal resistance and the slight increase in the wetted surface area. The maximum average heat transfer enhancement ratios compared to a plain surface at a temperature difference range of 15-75 K for enhanced surfaces M3, M2, and Ml are similar to 67, similar to 31, and similar to 23% at a volumetric flow rate and nozzle-to-surface distance of 180 mL/min and 10 mm, respectively. Additionally, the heat transfer characteristics of enhanced surface M3 were compared based on the wetted surface area at the same operating conditions with a surface enhanced with only straight grooves, having a depth and width of 500 x 200 mu m. The comparison showed that, at a volumetric flux of 12.73 L/(m(2).s), M3 has better thermal characteristics than the surface modified with straight grooves by 34%.
引用
收藏
页数:17
相关论文
共 29 条
[1]   Thermal conductivity and viscosity of deionised water and ethylene glycol-based nanofluids [J].
Abdullah, A. ;
Mohamad, I. S. ;
Hashim, A. Y. Bani ;
Abdullah, N. ;
Wei, P. B. ;
Isa, M. H. Md. ;
Abidin, S. Zainal .
JOURNAL OF MECHANICAL ENGINEERING AND SCIENCES, 2016, 10 (03) :2249-2261
[2]  
Abdulrazzaq N.M., 2019, EFFECT CHAMBER PRESS
[3]   Spray characteristics and spray cooling heat transfer in the non-boiling regime [J].
Cheng, Wen-Long ;
Han, Feng-Yun ;
Liu, Qi-Nie ;
Fan, Han-Lin .
ENERGY, 2011, 36 (05) :3399-3405
[4]   The Nukiyama curve in water spray cooling: Its derivation from temperature-time histories and its dependence on the quantities that characterize drop impact [J].
Ciofalo, Michele ;
Caronia, Antonino ;
Di Liberto, Massimiliano ;
Puleo, Salvo .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2007, 50 (25-26) :4948-4966
[5]   A comparative study of cooling of high power density electronics using sprays and microjets [J].
Fabbri, M ;
Jiang, SJ ;
Dhir, VK .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2005, 127 (01) :38-48
[6]   Effects of nozzle positioning on single-phase spray cooling [J].
Gao, Xuan ;
Li, Ri .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 115 :1247-1257
[7]   EXPERIMENTAL-STUDY OF SPRAY COOLING WITH FREON-113 [J].
GHODBANE, M ;
HOLMAN, JP .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1991, 34 (4-5) :1163-1174
[8]  
Hibbeler R.C., 1995, ENG MECH STATICS DYN, V7th
[9]  
Holman J.P., 2001, Experimental methods for engineers, V7th
[10]  
Incropera F.P., 1990, FUNDAMENTALS HEAT MA