The use and misuse of curve fitting in the analysis of core X-ray photoelectron spectroscopic data

被引:51
作者
Sherwood, Peter M. A. [1 ]
机构
[1] Univ Washington, Dept Chem, Box 351700, Seattle, WA 98195 USA
关键词
VALENCE-BAND; SPECTRA; RESOLUTION; OXIDATION; SURFACES; VOIGT;
D O I
10.1002/sia.6629
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Core X-ray photoelectron spectroscopic (XPS) data often contain overlapping chemically shifted peaks that differ in their width, peak shape, and intensity. The spectra may be complicated by the presence of satellite and multiplet splitting features as well as from the X-ray satellites that arise when achromatic X-radiation is used. Curve fitting has been extensively used for more than the past 50 years as a means of extracting chemical information from the overlapping features in core XPS. Our understanding of the key components of this approach, such as the fitting function and the spectral background, has improved substantially over the years. XPS is now the most widely used surface analytical method, and many users often have their principal expertise in other areas. While the associated computer software in most XPS instruments has powerful data analysis techniques, including curve fitting, provided by the manufacturer or by a separate commercial source, the application of these techniques may not always be appropriately applied. This perspective article gives the author's view of the main issues that impact the use of curve fitting, together with a description of some approaches that misuse curve fitting leading to erroneous conclusions about the surface chemistry. The article is illustrated by examples showing the fitting of various types of spectra using true Voigt functions.
引用
收藏
页码:589 / 610
页数:22
相关论文
共 41 条
[1]   X-RAY PHOTOELECTRON SPECTROSCOPIC STUDIES OF ELECTRODE SURFACES USING A NEW CONTROLLED TRANSFER TECHNIQUE .2. RESULTS FOR A MOLYBDENUM ELECTRODE AND THE CURVE FITTING PROCEDURE [J].
ANSELL, RO ;
DICKINSON, T ;
POVEY, AF ;
SHERWOOD, PMA .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1979, 98 (01) :79-89
[2]  
Barreca D., 2001, Surface Science Spectra, V8, P258, DOI 10.1116/11.20020801
[3]   High-resolution photoelectron spectroscopy studies on WO3 films modified by Ag addition [J].
Bittencourt, C ;
Felten, A ;
Mirabella, F ;
Ivanov, P ;
Llobet, E ;
Silva, MAP ;
Nunes, LAO ;
Pireaux, JJ .
JOURNAL OF PHYSICS-CONDENSED MATTER, 2005, 17 (43) :6813-6822
[4]  
Carlson TA, 1975, PHOTOELECTRON AUGER, P24
[5]   Chemical state information from the near-peak region of the X-ray photoelectron background [J].
Castle, JE ;
Salvi, AM .
JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 2001, 114 :1103-1113
[6]   MANY-ELECTRON SINGULARITY IN X-RAY PHOTOEMISSION AND X-RAY LINE SPECTRA FROM METALS [J].
DONIACH, S ;
SUNJIC, M .
JOURNAL OF PHYSICS PART C SOLID STATE PHYSICS, 1970, 3 (02) :285-&
[7]  
Du Pont Instruments, 1968, ANAL CHEM, V40, p20A
[8]   HIGH-ENERGY XPS USING A MONOCHROMATED AG L-ALPHA SOURCE - RESOLUTION, SENSITIVITY AND PHOTOELECTRIC CROSS-SECTIONS [J].
EDGELL, MJ ;
PAYNTER, RW ;
CASTLE, JE .
JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 1985, 37 (03) :241-256
[9]  
Engelhard M., 2000, Surface Science Spectra, V7, P1, DOI 10.1116/1.1311915
[10]   X-RAY PHOTOELECTRON SPECTROSCOPY OF SOME DIMETHYLAMINO-SUBSTITUTED CYCLOTRIPHOSPHAZENES [J].
GREEN, B ;
RIDLEY, DC ;
SHERWOOD, PM .
JOURNAL OF THE CHEMICAL SOCIETY-DALTON TRANSACTIONS, 1973, (10) :1042-1044