Development of energy labels for room air conditioner in Malaysia: methodology and results

被引:18
|
作者
Mahlia, TMI [1 ]
Masjuki, HH [1 ]
Choudhury, IA [1 ]
机构
[1] Univ Malaya, Dept Engn Mech, Kuala Lumpur 50603, Malaysia
关键词
energy labels; appliance labeling; energy guide; room air conditioner;
D O I
10.1016/S0196-8904(01)00145-5
中图分类号
O414.1 [热力学];
学科分类号
摘要
Because of the rapid economic growth in the past, the usage of residential electrical appliances for the last two decades has increased rapidly in Malaysia. Like other developing countries with hot and humid climates, she has been experiencing dramatic growth in the number of air conditioners used from 13,251 units in 1970 to 253,399 in 1991, and it will be about 1,511,276 in the year 2020. In order to reduce energy consumption in the residential sector, the Department of Electricity and Gas Supply, Malaysia, considers implementing energy labels for household electrical appliances, including room air conditioners, sometime in the coming year. The purpose of the energy labels is to provide consumers a guideline to compare the size, features, price and efficiency of the appliance. This paper attempts to propose an energy label for room air conditioners in this country based on survey data. This label is also suitable for other appliances without major modification. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1985 / 1997
页数:13
相关论文
共 50 条
  • [21] ROOM AIR CONDITIONER DESIGN PARAMETERS - PERFORMANCE
    METCALFE, FS
    ASHRAE JOURNAL, 1970, 12 (01): : 43 - &
  • [22] Limiting the impact of increasing cooling demand in the European union: Results from a study on room air-conditioner energy efficiency
    Adnot, Jérôme
    Orphelin, Matthieu
    Lopes, Carlos
    Waide, Paul
    Proceedings ACEEE Summer Study on Energy Efficiency in Buildings, 2000, 10 : 1 - 10
  • [23] Energy conservation and thermal environment analysis of room air conditioner with intermittent supply airflow
    Fan, Yunqing
    Toyoshima, Masaki
    Saito, Makoto
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2018, 13 (01) : 84 - 91
  • [24] Energy audit in residential building - replacement of portable air conditioner by an energy efficient centralised air conditioner
    Balan, K. N.
    Yashvanth, U.
    INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2020, 41 (02) : 179 - 182
  • [25] Energy analysis and optimization about room conditioner
    Zhu, PG
    Yu, WP
    Zhang, XS
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 479 - 484
  • [26] HCR of heat pump room air conditioner in China
    Wang, Baolong
    Shi, Wenxing
    Chen, Quan
    BUILDING SIMULATION 2007, VOLS 1-3, PROCEEDINGS, 2007, : 614 - 618
  • [27] FAN SYSTEM OF A ROOM AIR CONDITIONER WITH A THIN DEPTH
    TANAKA, S
    TAKUSHIMA, A
    SHINOBU, Y
    SHARP TECHNICAL JOURNAL, 1988, (39): : 59 - 62
  • [28] Matching Study of Room Air Conditioner and Conditioned Space
    Wang, Qian
    Meng, Qinglin
    CIVIL, STRUCTURAL AND ENVIRONMENTAL ENGINEERING, PTS 1-4, 2014, 838-841 : 1934 - 1938
  • [29] The optimized match method enhances the energy efficiency ratio (EER) of room air-conditioner
    Wang Zhiyuan
    Hetao
    Xu Zhiliang
    Luohao
    Dang Hongchang
    2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [30] Mitigation of emissions through energy efficiency standards for room air conditioners in Malaysia
    Mahlia, TMI
    Masjuki, HH
    Saidur, R
    Amalina, MA
    ENERGY POLICY, 2004, 32 (16) : 1783 - 1787