MODELING OF MICROBUBBLE-ENHANCED HIGH-INTENSITY FOCUSED ULTRASOUND

被引:17
作者
Gnanaskandan, Aswin [1 ]
Hsiao, Chao-Tsung [1 ]
Chahine, Georges [1 ]
机构
[1] Dynaflow Inc, 10621-J Iron Bridge Rd, Jessup, MD 20794 USA
基金
美国国家卫生研究院;
关键词
High-intensity focused ultrasound; Microbubbles; Bubble dynamics; Numerical modeling; Cancer treatment; BUBBLE DYNAMICS; SHOCK PROPAGATION; NUMERICAL-MODEL; CONTRAST AGENT; CAVITATION; VALIDATION; SIMULATION; EQUATIONS; ABLATION; LIQUID;
D O I
10.1016/j.ultrasmedbio.2019.02.022
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Heat enhancement at the target in a high intensity focused ultrasound (HIFU) field is investigated by considering the effects of the injection of microbubbles in the vicinity of the tumor to be ablated. The interaction between the bubble cloud and the HIFU field is investigated using a 3-D numerical model. The propagation of non-linear ultrasonic waves in the tissue or in a phantom medium is modeled using the compressible Navier-Stokes equations on a fixed Eulerian grid, while the microbubbles dynamics and motion are modeled as discrete singularities, which are tracked in a Lagrangian framework. These two models are coupled to each other such that both the acoustic field and the bubbles influence each other. The resulting temperature rise in the field is calculated by solving a heat transfer equation applied over a much longer time scale. The compressible continuum part of the model is validated by conducting axisymmetric HIFU simulations without microbubbles and comparing the pressure and temperature fields against available experiments. The coupled Eulerian-Lagrangian approach is then validated against existing experiments conducted with a phantom tissue. The bubbles are distributed randomly in a 3-D fashion inside a cylindrical volume, while the background acoustic field is assumed axisymmetric. The presence of microbubbles modifies the ultrasound field in the focal region and significantly enhances heat deposition. The various mechanisms through which heat deposition is increased are then examined. Among these effects, viscous damping of the bubble oscillations is found to be the main contributor to the enhanced heat deposition. The effects of the initial void fraction in the cloud are then sought by considering the changes in the attenuation of the primary ultrasonic wave and the modifications of the enhanced heat deposition in the focal region. It is observed that although high bubble void fractions lead to increased heat deposition, they also cause significant pre-focal heating because of acoustic shielding. The effects of the microbubble cloud size and its location in the focal region are studied, and the effects of these parameters in altering the temperature rise and the location of the temperature peak are discussed. It is found that concentrating the bubbles adjacent to the focus and farther away from the acoustic source leads to effective heat deposition. Finally, the presence of a shell at the bubble surface, as in contrast agents, is seen to reduce heat deposition by restraining bubble oscillations. (C) 2019 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:1743 / 1761
页数:19
相关论文
共 51 条
[1]   Numerical simulation of shock propagation in a polydisperse bubbly liquid [J].
Ando, Keita ;
Colonius, Tim ;
Brennen, Christopher E. .
INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2011, 37 (06) :596-608
[2]  
Bakhvalov N.S., 1987, Nonlinear Theory of Sound Beams
[3]   2-PHASE FLOW EQUATIONS FOR A DILUTE DISPERSION OF GAS-BUBBLES IN LIQUID [J].
BIESHEUVEL, A ;
VANWIJNGAARDEN, L .
JOURNAL OF FLUID MECHANICS, 1984, 148 (NOV) :301-318
[4]   Acoustic characterization of high intensity focused ultrasound fields: A combined measurement and modeling approach [J].
Canney, Michael S. ;
Bailey, Michael R. ;
Crum, Lawrence A. ;
Khokhlova, Vera A. ;
Sapozhnikov, Oleg A. .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2008, 124 (04) :2406-2420
[5]   Modeling of surface cleaning by cavitation bubble dynamics and collapse [J].
Chahine, Georges L. ;
Kapahi, Anil ;
Choi, Jin-Keun ;
Hsiao, Chao-Tsung .
ULTRASONICS SONOCHEMISTRY, 2016, 29 :528-549
[6]  
Chahine GL., 2014, Advanced Experimental and Numerical Techniques for Cavitation Erosion Prediction, P345, DOI [10.1007/978-94-017-8539-615, DOI 10.1007/978-94-017-8539-615]
[7]  
Choi JK, SESS L21 COMP FLUID
[8]   Effect of microbubble contrast agent during high intensity focused ultrasound ablation on rabbit liver in vivo [J].
Chung, Dong Jin ;
Cho, Se Hyun ;
Lee, Jae Mun ;
Hahn, Seong-Tae .
EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (04) :E519-E523
[9]   THE EFFECTS OF AN ELASTIC SOLID-SURFACE LAYER ON THE RADIAL PULSATIONS OF GAS-BUBBLES [J].
CHURCH, CC .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1995, 97 (03) :1510-1521
[10]   A DIRECT EULERIAN MUSCL SCHEME FOR GAS-DYNAMICS [J].
COLELLA, P .
SIAM JOURNAL ON SCIENTIFIC AND STATISTICAL COMPUTING, 1985, 6 (01) :104-117