Comparison of membrane fouling at constant flux and constant transmembrane pressure conditions

被引:164
作者
Miller, Daniel J.
Kasemset, Sirirat
Paul, Donald R.
Freeman, Benny D. [1 ]
机构
[1] Univ Texas Austin, Ctr Energy & Environm Resources, Dept Chem Engn, Austin, TX 78712 USA
基金
美国国家科学基金会;
关键词
Constant flux; Constant transmembrane pressure; Threshold flux; Critical flux; Fouling; Ultrafiltration; CROSS-FLOW MICROFILTRATION; REVERSE-OSMOSIS MEMBRANES; THRESHOLD FLUX; PERMEATE FLUX; ULTRAFILTRATION; PERFORMANCE; FILTRATION; DEPOSITION; WHEY;
D O I
10.1016/j.memsci.2013.12.027
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Membrane fouling is often characterized in the laboratory by flux decline experiments, where an increase in transport resistance due to accumulation of foulants on and/or in a membrane is manifested as a decrease in permeate flux with filtration time at fixed transmembrane pressure. However, many industrial microfiltration and ultrafiltration applications operate at constant permeate flux, and there are Few reports comparing these modes of operation. In this study, emulsified oil fouling of polysullone ultrafiltration membranes was studied using both constant permeate flux and constant transmembrane pressure experiments. Mass transfer resistance changes during fouling were compared between constant Flux experiments and constant transmembrane pressure experiments performed at an initial flux equal to the flux imposed during the constant flux experiment. At low fluxes, the transport resistance and its change with permeate volume per unit area agreed within experimental error regardless of operational mode. In contrast, at high fluxes, the change in membrane resistance with permeate volume per unit area was much higher in constant flux than in constant transmembrane pressure experiments. The threshold flux, defined recently as the flux at which the rate of fouling begins to increase rapidly, separates the regimes of good and poor agreement between the two types of experiments. The weak form of the critical flux, below which spontaneous adsorption is the only significant resistance imposed by foulant, was also observed. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:505 / 515
页数:11
相关论文
共 50 条
  • [1] AIMAR P, 1989, CHEM ENG RES DES, V67, P255
  • [2] Alspach B, 2008, J AM WATER WORKS ASS, V100, P84
  • [3] [Anonymous], 2004, MEMBRANE TECHNOLOGY
  • [4] Critical and sustainable fluxes: Theory, experiments and applications
    Bacchin, P.
    Aimar, P.
    Field, R. W.
    [J]. JOURNAL OF MEMBRANE SCIENCE, 2006, 281 (1-2) : 42 - 69
  • [5] Critical Flux Determination by Flux-Stepping
    Beier, Soren Prip
    Jonsson, Gunnar
    [J]. AICHE JOURNAL, 2010, 56 (07) : 1739 - 1747
  • [6] THE BEHAVIOR OF SUSPENSIONS AND MACROMOLECULAR SOLUTIONS IN CROSS-FLOW MICROFILTRATION
    BELFORT, G
    DAVIS, RH
    ZYDNEY, AL
    [J]. JOURNAL OF MEMBRANE SCIENCE, 1994, 96 (1-2) : 1 - 58
  • [7] ULTRAFILTRATION CHARACTERISTICS OF OIL-DETERGENT-WATER SYSTEMS - MEMBRANE FOULING MECHANISMS
    BHATTACHARYYA, D
    JUMAWAN, AB
    GRIEVES, RB
    HARRIS, LR
    [J]. SEPARATION SCIENCE AND TECHNOLOGY, 1979, 14 (06) : 529 - 549
  • [8] PROPERTIES OF MICROFILTRATION MEMBRANES - FLUX LOSS DURING CONSTANT PRESSURE PERMEATION OF BOVINE SERUM-ALBUMIN
    BOWEN, WR
    GAN, Q
    [J]. BIOTECHNOLOGY AND BIOENGINEERING, 1991, 38 (07) : 688 - 696
  • [9] Permeate flux decline in cross-flow microfiltration at constant pressure
    Buetehorn, S.
    Carstensen, F.
    Wintgens, T.
    Melin, T.
    Volmering, D.
    Vossenkaul, K.
    [J]. DESALINATION, 2010, 250 (03) : 985 - 990
  • [10] Fouling mechanisms in low-pressure membrane filtration in the presence of an adsorbent cake layer
    Cai, Zhenxiao
    Wee, Claudia
    Benjamin, Mark M.
    [J]. JOURNAL OF MEMBRANE SCIENCE, 2013, 433 : 32 - 38