Prospective outcome analysis following tenodesis of the long head of the biceps tendon along with locking plate osteosynthesis for proximal humerus fractures

被引:6
|
作者
Greve, F. [1 ]
Beirer, M. [1 ]
Zyskowski, M. [1 ]
Croenlein, M. [1 ]
Mueller, M. [1 ]
Pesch, S. [1 ]
Felix, S. [1 ]
Biberthaler, P. [1 ]
Buchholz, A. [1 ]
Kirchhoff, C. [1 ]
机构
[1] Tech Univ Munich, Klinikum Rechts Isar, Klin & Poliklin Unfallchirurg, Ismaningerstr 22, D-81675 Munich, Germany
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2019年 / 50卷 / 03期
关键词
Biceps muscle; Long head of the biceps tendon; Tenodesis; Proximal humerus fracture; Plate fixation; LABRAL TEARS; TENOTOMY; SHOULDER; ARTHROSCOPY; STABILITY; BRACHII; MUSCLE;
D O I
10.1016/j.injury.2019.02.003
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Fractures of the proximal humerus are often associated with lesions of the long head of the biceps (LHB) tendon. This often leads to prolonged shoulder pain. Hence, many surgeons decide to perform a tenodesis of the LHB tendon simultaneous to ORIF. The purpose of this study was to evaluate the postoperative outcome after interlocking plate fixation and biceps tenodesis for treating proximal humerus fractures. Methods: 56 patients (38 females, 18 male) suffering from proximal humerus fractures who underwent surgery were retrospectively included. 26 of these 56 patients (19% Neer II, 38% Neer III, 43% Neer IV) were treated with simultaneous tenodesis of the LHB tendon when ORIF using interlocking plate fixation was performed. 30 patients (17% Neer II, 40% Neer III, 43% Neer IV) served as control group receiving only interlocking plate fixation. The patients were asked to complete the Munich Shoulder Questionnaire (MSQ) for evaluation of postoperative shoulder function. Results of the Disabilities of the Arm, Shoulder and Hand (DASH) Score and Shoulder Pain and Disability Index (SPADI) were calculated from the MSQ. Patients were clinically evaluated for a positive O'Brien test and Popeye sign. Results: The tenodesis group demonstrated significant superior outcome regarding the MSQ(mean 90.47 points vs. 79.41 points, p = 0.006), DASH Score (mean 4.2 points vs. 16.81 points, p = 0.017) and SPADI (mean 94.59 points vs. 83.56, p = 0.045). Flexion, external rotation and the capability of throwing a soft ball were significantly improved in the tenodesis group compared to the control group. The O'Brien test as indicator for lesions of the LHB was positive in fewer patients of the tenodesis group (2/26, vs. 21/30, p = 0.001). There was no significant difference of a positive Popeye Sign. Conclusion: Our results show evidence of an improved shoulder function when a simultaneous tenodesis of the LHB tendon is performed during treatment of proximal humerus fractures using interlocking plate fixation. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:681 / 685
页数:5
相关论文
共 50 条
  • [1] The tendon of the long head of the biceps in complex proximal humerus fractures: A histological perspective
    Tosounidis, Theodoros
    Hadjileontis, Constantine
    Georgiadis, Minas
    Kafanas, Antonios
    Kontakis, George
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2010, 41 (03): : 273 - 278
  • [2] Rotator cuff repair with or without proximal end detachment for long head of the biceps tendon tenodesis
    Mardani-Kivi, Mohsen
    Asadi, Kamran
    Izadi, Amin
    Leili, Ehsan Kazemnejad
    CLINICS IN SHOULDER AND ELBOW, 2022, 25 (02): : 101 - 105
  • [3] Outcomes following long head of biceps tendon tenodesis
    AlQahtani S.M.
    Bicknell R.T.
    Current Reviews in Musculoskeletal Medicine, 2016, 9 (4) : 378 - 387
  • [4] A Prospective Clinical Study of Proximal Humerus Fractures Treated With a Locking Proximal Humerus Plate
    Yang, Huiguang
    Li, Zhongze
    Zhou, Feng
    Wang, Daoyuan
    Zhong, Baoliang
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 (01) : 11 - 17
  • [5] Functional Outcome and Complications in Management of Proximal Humerus Fractures Operated with Proximal Humerus Locking Plate
    George, P. K.
    Dasgupta, B.
    Bhaladhare, S. M.
    Reddy, B. P., V
    Jain, A.
    Jogani, A. D.
    MALAYSIAN ORTHOPAEDIC JOURNAL, 2021, 15 (02) : 47 - 54
  • [6] Biomechanical analysis of plate osteosynthesis systems for proximal humerus fractures
    Lever, James P.
    Aksenov, Sergei A.
    Zdero, Rad
    Ahn, Henry
    Mckee, Michael D.
    Schemitsch, Emil H.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2008, 22 (01) : 23 - 29
  • [7] Is Device Removal Necessary after Fixed-Angle Locking Plate Osteosynthesis of Proximal Humerus Fractures?
    Kim, Beom-Soo
    Kim, Du-Han
    Choi, Jung-Hoon
    Choi, Byung-Chan
    Cho, Chul-Hyun
    MEDICINA-LITHUANIA, 2022, 58 (03):
  • [8] Proximal humeral fractures treated with hemiarthroplasty: Does tenodesis of the long head of the biceps improve results?
    Soliman, Omar A.
    Koptan, Wael M. T.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2013, 44 (04): : 461 - 464
  • [9] Small-incision open distal subpectoral vs. arthroscopic proximal biceps tenodesis for biceps long head tendon lesions with repair of rotator cuff tears
    Yi, Gang
    Yang, Jing
    Zhang, Lei
    Liu, Yang
    Guo, Xiaoguang
    Fu, Shijie
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2020, 19 (02) : 861 - 870
  • [10] Plate osteosynthesis versus non-surgical treatment in displaced proximal humerus fractures—long term functional outcome and quality of life
    Lisa Klute
    Christian Pfeifer
    Arne Berner
    Volker Alt
    Maximilian Kerschbaum
    Leopold Henssler
    European Journal of Orthopaedic Surgery & Traumatology, 35 (1)