MRI Evaluation of Lacrimal Drainage After External and Endonasal Dacryocystorhinostomy

被引:14
作者
Detorakis, Efstathios T. [1 ]
Drakonaki, Eleni E. [2 ]
Bizakis, Ioannis [3 ]
Papadaki, Efrosini [2 ]
Tsilimbaris, Miltiadis K. [1 ]
Pallikaris, Ioannis G. [1 ]
机构
[1] Univ Hosp Heraklion, Dept Ophthalmol, Iraklion 71110, Crete, Greece
[2] Univ Hosp Heraklion, Dept Med Imaging, Iraklion 71110, Crete, Greece
[3] Univ Hosp Heraklion, Dept ENT, Iraklion 71110, Crete, Greece
关键词
TEAR FLOW; SCINTIGRAPHY; MECHANICS; EPIPHORA;
D O I
10.1097/IOP.0b013e3181ac5320
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: External and endonasal dacryocystorhinostomy (EX-DCR and EN-DCR, respectively) affect the tear drainage mechanism. This study evaluates the preservation of "lacrimal pump" function in both procedures. Methods: Cases of successful EN-DCR (4 patients) and EX-DCR (4 patients) were included. All patients underwent MRI of the rhinostomy areas, at least 6 months postoperatively. The vertical diameter of rhinostomy (both osseous and soft-tissue apertures) was measured in T(1)-oriented images, whereas the signal intensity levels were examined for 3 regions of interest (ROIs) in T(2)-oriented (true fast imaging steady state pulse) images with instillation of normal saline to the conjunctival fornices, both before and after blinking (activation of the "lacrimal pump"). ROI I corresponded to the globe (control), ROI 2 corresponded to the inferior conjunctival fornix, and ROI 3 corresponded to the rhinostomy site. Results: Signal intensity in ROI 3 (rhinostomy) was significantly increased after blinking in both EX-DCR and EN-DCR cases. The increase was significantly higher in the latter. Signal intensity changes in ROI 3 were significantly correlated with rhinostomy size in both groups, whereas the respective correlations with the postoperative interval were not statistically significant. Conclusions: Findings imply that the "lacrimal pump" is active following DCR and may be better preserved in the EN-DCR than in the EX-DCR group. Persistent epiphora after patent DCR may thus be attributed to a defective "pump" function and treated accordingly.
引用
收藏
页码:289 / 292
页数:4
相关论文
共 19 条
[1]   Anophthalmic socket and orbital implants - Role of CT and MR imaging [J].
Ainbinder, DJ ;
Haik, BG ;
Mazzoli, RA .
RADIOLOGIC CLINICS OF NORTH AMERICA, 1998, 36 (06) :1133-+
[2]   Tear flow dynamics in the human nasolacrimal ducts - a pilot study using dynamic magnetic resonance imaging [J].
Amrith, S ;
Goh, PS ;
Wang, SC .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2005, 243 (02) :127-131
[3]  
BECKER BB, 1992, OPHTHALMOLOGY, V99, P1139
[4]   Lower eyelid laxity in functional acquired epiphora: Evaluation with quantitative scintigraphy [J].
Detorakis, ET ;
Zissimopoulos, A ;
Katernellis, G ;
Drakonaki, EE ;
Ganasouli, DL ;
Kozobolis, VP .
OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2006, 22 (01) :25-29
[5]  
DOANE MG, 1981, OPHTHALMOLOGY, V88, P844
[6]   Comparison of external dacryocystorhinostomy with nonlaser endonasal dacryocystorhinostomy [J].
Dolman, PJ .
OPHTHALMOLOGY, 2003, 110 (01) :78-84
[7]   Ultrasonic assessment of rhinostomy size following external dacryocystorhinostomy [J].
Ezra, E ;
Restori, M ;
Mannor, GE ;
Rose, GE .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1998, 82 (07) :786-789
[8]  
FAYET B, 1994, J FR OPHTALMOL, V17, P195
[9]   LACRIMAL SCINTIGRAPHY IN THE DIAGNOSIS OF EPIPHORA [J].
HANNA, IT ;
MACEWEN, CJ ;
KENNEDY, N .
NUCLEAR MEDICINE COMMUNICATIONS, 1992, 13 (06) :416-420
[10]  
HILL JC, 1974, CAN J OPHTHALMOL, V9, P411