A radiostereometric analysis of the movements of the sacroiliac joints in the reciprocal straddle position

被引:87
作者
Sturesson, B
Uden, A
Vleeming, A
机构
[1] NVS Angelholm, Dept Orthopaed, Angelholm, Sweden
[2] Univ Lund, Malmo Univ Hosp, Dept Orthopaed, Lund, Sweden
[3] Erasmus Univ, Dept Anat, Spine & Joint Ctr Rotterdam, Rotterdam, Netherlands
[4] Erasmus Univ, Dept Anat, Res Grp Musculoskeletal Syst, Rotterdam, Netherlands
关键词
low back pain; pelvic pain; radiostereometric analysis; sacroiliac joint;
D O I
10.1097/00007632-200001150-00012
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study design. A radiostereometric analysis of the reciprocal straddle position. Objectives. To evaluate the magnitude of rotation in the sacroiliac joints in the reciprocal straddle position. Summary of Background Data. the reciprocal straddle has been objectified in different studies, using different techniques, to show a sacroiliac motion between 5 degrees and 36 degrees. Previous studies with radiostereometric analysis during different provocations reported much smaller movements. Methods. Six women with posterior pelvic pain of long duration after pregnancy (n = 5) and sacroilitis (n = 1) underwent radiostereometric analysis in the sustained reciprocal straddle position. Results. A reciprocal movement could be demonstrated in the sacroiliac joints in the reciprocal straddle position. However, the movements were 10 times smaller than reported in earlier studies of the reciprocal straddle position. Conclusions. It was possible to demonstrate reciprocal movements of the sacroiliac joints in the straddle position. However, the radiostereometric analysis technique showed the movements to be small, as reported in other mobility studies.
引用
收藏
页码:214 / 217
页数:4
相关论文
共 12 条
  • [1] MOVEMENTS IN SACROILIAC JOINTS DEMONSTRATED WITH ROENTGEN STEREOPHOTOGRAMMETRY
    EGUND, N
    OLSSON, TH
    SCHMID, H
    SELVIK, G
    [J]. ACTA RADIOLOGICA-DIAGNOSIS, 1978, 19 (05): : 833 - 846
  • [2] MOBILITY OF THE SACROILIAC JOINTS INVITRO
    KISSLING, R
    BRUNNER, C
    JACOB, HAC
    [J]. ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1990, 128 (03): : 282 - 288
  • [3] LOAD-DISPLACEMENT BEHAVIOR OF SACROILIAC JOINTS
    MILLER, JAA
    SCHULTZ, AB
    ANDERSSON, GBJ
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 1987, 5 (01) : 92 - 101
  • [4] A ROENTGEN STEREOPHOTOGRAMMETRIC SYSTEM - CONSTRUCTION, CALIBRATION AND TECHNICAL ACCURACY
    SELVIK, G
    ALBERIUS, P
    ARONSON, AS
    [J]. ACTA RADIOLOGICA-DIAGNOSIS, 1983, 24 (04): : 343 - 352
  • [5] ROENTGEN STEREOPHOTOGRAMMETRIC ANALYSIS
    SELVIK, G
    [J]. ACTA RADIOLOGICA, 1990, 31 (02) : 113 - 126
  • [6] Selvik G., 1989, Acta Orthop., V60, P1, DOI [10.3109/17453678909154184, DOI 10.3109/17453678909154184]
  • [7] Sacroiliac motion for extreme hip positions - A fresh cadaver study
    Smidt, GL
    Wei, SH
    McQuade, K
    Barakatt, E
    Sun, TS
    Stanford, W
    [J]. SPINE, 1997, 22 (18) : 2073 - 2082
  • [8] SACROILIAC KINEMATICS FOR RECIPROCAL STRADDLE POSITIONS
    SMIDT, GL
    MCQUADE, K
    WEI, SH
    BARAKATT, E
    [J]. SPINE, 1995, 20 (09) : 1047 - 1054
  • [9] SMIDT GL, 1997, INTERINNOMINATE RANG
  • [10] Can an external frame fixation reduce the movements in the sacroiliac joint?: A radiostereometric analysis of 10 patients
    Sturesson, B
    Udén, A
    Önsten, I
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1999, 70 (01): : 42 - 46