Unfolding X-ray spectra using a flat panel detector

被引:0
|
作者
Gallardo, Sergio [1 ]
Juste, Belen [1 ]
Pozuelo, Fausto [1 ]
Rodenas, Jose [1 ]
Querol, Andrea [1 ]
Verdu, Gumersindo [1 ]
机构
[1] Univ Politecn Valencia, Valencia 46022, Spain
关键词
REGULARIZATION;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
It is difficult to measure the energy spectrum of Xray tubes due to the pile up effect produced by the high fluence of photons. Using attenuating materials, appropriate detector devices and the Monte Carlo method, primary X-ray spectrum of these devices can be estimated. In this work, a flat panel detector with a PMMA wedge has been used to obtain a dose curve corresponding to certain working conditions of a radiodiagnostic X-ray tube. The relation between the dose curve recorded by the flat panel and the primary X-ray spectrum is defined by a response function. Normally this function can be approximated by a matrix, which can be obtained by means of the Monte Carlo method. Knowing the measured dose curve and the response matrix, the primary Xray spectrum can be unfolded. However, there are some problems that strongly affect the applicability of this method: i.e. technical features of the flat panel and inherent characteristics of the involved radiation physics (ill-posed problem). Both aspects are analyzed in this work, concluding that the proposed method can be applied with an acceptable accuracy for spectra without characteristic lines, for instance, tungsten anode in the 50-70 kVp range.
引用
收藏
页码:2384 / 2387
页数:4
相关论文
共 50 条
  • [21] Image quality evaluation of flat panel detector binning in X-ray fluoroscopy
    Srinivas, Y
    Wilson, DL
    2002 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, PROCEEDINGS, 2002, : 177 - 180
  • [22] Development and evaluation of a portable amorphous silicon flat panel X-ray detector
    Watanabe, N
    Mochizuki, C
    Kameshima, T
    Yamazaki, T
    Court, L
    Hayashida, S
    Morishita, M
    Ohta, S
    MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 103 - 114
  • [23] Physical Characteristics of a New Flat-Panel Digital X-Ray Detector
    Cho, H.
    Kim, H.
    Park, H.
    Lee, C.
    Yu, A.
    Kim, D.
    Lee, Y.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [24] Measurement of the MTF of a flat panel detector in variable resolution x-ray detection
    Zhang, S.
    DiBianca, F.
    MEDICAL PHYSICS, 2007, 34 (06) : 2620 - 2620
  • [25] High resolution flat-panel X-ray detector for digital radiography
    Park, JK
    Kang, SS
    Cha, BY
    Kim, JY
    Kim, SY
    Choi, HK
    Nam, SH
    Healthcom 2005: 7th International Workshop on Enterprise Networking and Computing in Healthcare Industry, Proceedings, 2005, : 359 - 363
  • [26] Evaluation of a new radiographic system based on a flat panel X-ray detector
    Maack, I
    GuntherKohfahl, S
    Schroeder, H
    Spiess, K
    Neitzel, U
    RADIOLOGY, 1997, 205 : 109 - 109
  • [27] Performance of mobile digital X-ray fluoroscopy using a novel flat panel detector for intraoperative use
    Jeong, Chang-Won
    Ryu, Jong-Hyun
    Joo, Su-Chong
    Jun, Hong-Young
    Heo, Dong-Woon
    Lee, Jinseok
    Kim, Kyong-Woo
    Yoon, Kwon-Ha
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2015, 23 (03) : 365 - 372
  • [28] High-energy X-ray diffraction using the Pixium 4700 flat-panel detector
    Daniels, J. E.
    Drakopoulos, M.
    JOURNAL OF SYNCHROTRON RADIATION, 2009, 16 : 463 - 468
  • [29] Indirect X-Ray Detector Panel Using Multiple Cameras
    Hemtiwakorn, Khaisang
    Srisuk, Namthip
    Pintavirooj, Chuchart
    2008 INTERNATIONAL SYMPOSIUM ON COMMUNICATIONS AND INFORMATION TECHNOLOGIES, 2008, : 407 - +
  • [30] Concept of a Movable Flat Panel Detector for X-ray Imaging during Surgical Interventions
    Engel, S.
    Kaeseberg, M.
    Stopp, F.
    Fehlhaber, F.
    Keeve, E.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2012, 57 : 1113 - 1113