Unfolding X-ray spectra using a flat panel detector

被引:0
|
作者
Gallardo, Sergio [1 ]
Juste, Belen [1 ]
Pozuelo, Fausto [1 ]
Rodenas, Jose [1 ]
Querol, Andrea [1 ]
Verdu, Gumersindo [1 ]
机构
[1] Univ Politecn Valencia, Valencia 46022, Spain
关键词
REGULARIZATION;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
It is difficult to measure the energy spectrum of Xray tubes due to the pile up effect produced by the high fluence of photons. Using attenuating materials, appropriate detector devices and the Monte Carlo method, primary X-ray spectrum of these devices can be estimated. In this work, a flat panel detector with a PMMA wedge has been used to obtain a dose curve corresponding to certain working conditions of a radiodiagnostic X-ray tube. The relation between the dose curve recorded by the flat panel and the primary X-ray spectrum is defined by a response function. Normally this function can be approximated by a matrix, which can be obtained by means of the Monte Carlo method. Knowing the measured dose curve and the response matrix, the primary Xray spectrum can be unfolded. However, there are some problems that strongly affect the applicability of this method: i.e. technical features of the flat panel and inherent characteristics of the involved radiation physics (ill-posed problem). Both aspects are analyzed in this work, concluding that the proposed method can be applied with an acceptable accuracy for spectra without characteristic lines, for instance, tungsten anode in the 50-70 kVp range.
引用
收藏
页码:2384 / 2387
页数:4
相关论文
共 50 条
  • [1] Unfolding X-ray spectra using a flat panel detector. Determination of the accuracy of the method with the Monte Carlo method
    Gallardo, S.
    Rodenas, J.
    Verdu, G.
    RADIATION PHYSICS AND CHEMISTRY, 2019, 155 : 233 - 238
  • [2] An X-ray tomograph based on a flat panel detector
    Constantin, F.
    Pavel, C.
    Bugoi, R.
    Toderas, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 621 (1-3): : 685 - 689
  • [3] A Method for Measuring X-Ray Beam Profiles Using a Flat Panel Detector
    Sun, M.
    Star-Lack, J.
    Virshup, G.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [4] A LabVIEW driver for X-ray flat-panel detector
    Department of Biomedical Engineering, Huazhong University of Science and Technology, Ministry of Education, Wuhan 430074, China
    J X Ray Sci Technol, 2008, 4 (261-268):
  • [5] Flat panel X-ray detector based SPECT/CT
    Sowards-Emmerd, David
    Vesel, John
    Shao, Lingxiong
    Timmer, Jan
    Bertram, Matthias
    Ye, Jinghan
    Hines, Horace
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [6] A LabVIEW driver for X-ray flat-panel detector
    Bi, Kun
    Liu, Qian
    Lv, Xiaohua
    Luo, Qingming
    Zeng, Shaoqun
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2008, 16 (04) : 261 - 268
  • [7] X-ray microtomography system for small and light samples using a flat panel detector
    Vilar, A. B.
    dos Santos, T. M. P.
    Machado, A. S.
    Oliveira, D. F.
    Azeredo, S. R.
    Lopes, R. T.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (10):
  • [8] Detective quantum efficiency of flat panel CdZnTe x-ray detector
    Khym, GL
    Kim, KH
    Park, YJ
    Yang, HJ
    Kim, SU
    Jung, TR
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2004, 45 : S893 - S897
  • [9] X-ray scatter data for flat-panel detector CT
    Kyriakou, Yiannis
    Kalender, Willi A.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2007, 23 (01): : 3 - 15
  • [10] Measurement of the properties of a flat-panel gas X-ray detector
    Yun, Min-seok
    Cho, Sung-ho
    Oh, Kyung-min
    Kim, Min-woo
    Jung, Suk-hee
    Jang, Gi-won
    Heo, Seung-uk
    Kwon, Chul
    Nam, Sang-Hee
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 607 (01): : 162 - 165