Pacing parameters and success rates of permanent His-bundle pacing in patients with narrow QRS: a single-centre experience

被引:53
作者
Su, Lan [1 ,2 ]
Wu, Shengjie [1 ,2 ]
Wang, Songjie [1 ,2 ]
Wang, Zhengxian [1 ,2 ]
Xiao, Fangyi [1 ,2 ]
Shan, Peiren [1 ,2 ]
Zhou, Hao [1 ,2 ]
Huang, Zhouqing [1 ,2 ]
Xu, Lei [1 ,2 ]
Huang, Weijian [1 ,2 ]
机构
[1] Wenzhou Med Univ, Affiliated Hosp 1, Heart Ctr, Dept Cardiol, Wenzhou, Peoples R China
[2] Key Lab Cardiovasc Dis Wenzhou, Wenzhou 325000, Peoples R China
来源
EUROPACE | 2019年 / 21卷 / 05期
关键词
His-bundle pacing; Success rate; Threshold; Pacing lead; Pacemaker; Pacemaker implantation;
D O I
10.1093/europace/euy281
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims High and unstable capture thresholds affect the success rate of permanent His-bundle pacing (HBP). We aimed to introduce the modified techniques during different periods and the corresponding success rate of HBP implantation. Methods and results Patients from a single centre who had intrinsic QRS < 120 ms and HBP attempts were included in the study. The success rate and pacing parameters were described for three periods based on procedural modifications, i.e. Stage 1 using the conventional HBP procedure (August 2012 to May 2013), Stage 2 with addition of the dual-lead method (June 2013 to October 2014), and Stage 3 with the further addition of stability assessment during fixation (November 2014 to October 2016). The patients with successful permanent HBP were followed. A total of 310 patients were included with the average age of 70.3 +/- 10.7 years. The success rate of acute HBP was 84.85%, 98.3%, and 99.20% during Stages 1-3, respectively (P < 0.001). The permanent HBP implantation rates increased from 77.3% during Stage 1 to 85.7% during Stage 2 and 89.6% during Stage 3 (P = 0.07). The acute His-bundle capture threshold reduced from 1.30 +/- 0.7 V/0.5 ms during Stage 1 to 1.11 +/- 0.6 V/0.5 ms during Stage 2 and further to 0.85 +/- 0.51 V/0.5 ms during Stage 3 (P < 0.001). At the 12-month follow-up, the mean change in the HBP threshold decreased from 0.60 +/- 0.59 V/0.5 ms during Stage 1 to 0.33 +/- 0.39 V/0.5 ms during Stage 3 (P = 0.002). Conclusion The HBP implantation success rate, pacing threshold, and its stability during follow-up were improved by using the dual-lead method and stability assessment techniques.
引用
收藏
页码:763 / 770
页数:8
相关论文
共 15 条
[1]  
Ajijola Olujimi A, 2015, HeartRhythm Case Rep, V1, P429
[2]  
[Anonymous], 2016, J Innovations Card Rhythm Manage
[3]   Permanent, direct his-bundle pacing - A novel approach to cardiac pacing in patients with normal His-purkinje activation [J].
Deshmukh, P ;
Casavant, DA ;
Romanyshyn, M ;
Anderson, K .
CIRCULATION, 2000, 101 (08) :869-877
[4]  
Huang Weijian, 2018, Card Electrophysiol Clin, V10, P519, DOI 10.1016/j.ccep.2018.05.016
[5]   Long-term outcomes of His bundle pacing in patients with heart failure with left bundle branch block [J].
Huang, Weijian ;
Su, Lan ;
Wu, Shengjie ;
Xu, Lei ;
Xiao, Fangyi ;
Zhou, Xiaohong ;
Mao, Guangyun ;
Vijayaraman, Pugazhendhi ;
Ellenbogen, Kenneth A. .
HEART, 2019, 105 (02) :137-143
[6]   A Novel Pacing Strategy With Low and Stable Output: Pacing the Left Bundle Branch Immediately Beyond the Conduction Block [J].
Huang, Weijian ;
Su, Lan ;
Wu, Shengjie ;
Xu, Lei ;
Xiao, Fangyi ;
Zhou, Xiaohong ;
Ellenbogen, Kenneth A. .
CANADIAN JOURNAL OF CARDIOLOGY, 2017, 33 (12) :1736.e1-1736.e3
[7]   Benefits of Permanent His Bundle Pacing Combined With Atrioventricular Node Ablation in Atrial Fibrillation Patients With Heart Failure With Both Preserved and Reduced Left Ventricular Ejection Fraction [J].
Huang, Weijian ;
Su, Lan ;
Wu, Shengjie ;
Xu, Lei ;
Xiao, Fangyi ;
Zhou, Xiaohong ;
Ellenbogen, Kenneth A. .
JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2017, 6 (04)
[8]   Beneficial effects of upgrading to His bundle pacing in chronically paced patients with left ventricular ejection fraction &lt;50% [J].
Shan, Peiren ;
Su, Lan ;
Zhou, Xiaodong ;
Wu, Shengjie ;
Xu, Lei ;
Xiao, Fangyi ;
Zhou, Xiaohong ;
Ellenbogen, Kenneth A. ;
Huang, Weijian .
HEART RHYTHM, 2018, 15 (03) :405-412
[9]   Permanent His-bundle pacing is feasible, safe, and superior to right ventricular pacing in routine clinical practice [J].
Sharma, Parikshit S. ;
Dandamudi, Gopi ;
Naperkowski, Angela ;
Oren, Jess W. ;
Storm, Randle H. ;
Ellenbogen, Kenneth A. ;
Vijayaraman, Pugazhendhi .
HEART RHYTHM, 2015, 12 (02) :305-312
[10]   Pacing and sensing optimization of permanent His-bundle pacing in cardiac resynchronization therapy/implantable cardioverter defibrillators patients: value of integrated bipolar configuration [J].
Su, Lan ;
Xu, Lei ;
Wu, Sheng-jie ;
Huang, Wei-jian .
EUROPACE, 2016, 18 (09) :1399-1405