Study of the Hygrothermal Behavior of Wood Fiber Insulation Subjected to Non-Isothermal Loading

被引:19
作者
Slimani, Zakaria [1 ]
Trabelsi, Abdelkrim [1 ]
Virgone, Joseph [1 ]
Freire, Roberto Zanetti [2 ]
机构
[1] Univ Claude Bernard Lyon 1, INSA Lyon, Univ Lyon, CETHIL UMR5008,CNRS, F-69621 Villeurbanne, France
[2] Pontifical Catholic Univ Parana PUCPR, Ind & Syst Engn Grad Program PPGEPS, Polytech Sch EP, Rua Imaculada Conceicao 1555, BR-80215901 Curitiba, Parana, Brazil
来源
APPLIED SCIENCES-BASEL | 2019年 / 9卷 / 11期
关键词
heat and mass transfers; hygrothermal coupling; wood fiber insulation; water vapor adsorption; latent effects; HYGROSCOPIC BUILDING-MATERIALS; MOISTURE TRANSFER MODELS; EXPERIMENTAL-DATA SET; BENCHMARKING; 1-D; TRANSIENT HEAT; COUPLED HEAT; AIR;
D O I
10.3390/app9112359
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Building envelopes are constantly subjected to temperature and moisture gradients. This loading induces a complex response, particularly for highly hygroscopic insulating materials. Latent effects can no longer be neglected for these materials in which heat and moisture transfers are strongly coupled. The purpose of this article is to analyze the behavior of a wood fiber insulation subjected to non-isothermal loading under a vapor concentration gradient. An experimental setup and a mathematical model of hygrothermal transfer were developed to analyze the behavior of the wall. The mathematical model describes the main physical phenomena involved, notably water vapor adsorption and the dependence of thermophysical properties in state variables. The experimental setup developed allows studying a wall under controlled conditions. The temperature and relative humidity profiles within the wall were measured. The evolution of the profiles with time suggests that the adsorption of the water vapor occurs together with the redistribution of liquid water within the envelope. The comparison of the experimental results with the numerical model shows good agreement although the prediction can be improved during the transient phase. The comparisons of these results with a purely diffusive thermal transfer model show the limits of the latter and permit quantifying the latent effects on the total heat transfer.
引用
收藏
页数:12
相关论文
共 28 条
[1]  
ADEME, 2013, CHIFFR BAT EN ENV
[2]  
[Anonymous], THESIS
[3]  
[Anonymous], 2013, 12571 ISO
[4]   Experimental data set for validation of heat, air and moisture transport models of building envelopes [J].
Desta, Tadiwos Zerihun ;
Langmans, Jelle ;
Roels, Staf .
BUILDING AND ENVIRONMENT, 2011, 46 (05) :1038-1046
[5]  
Hagentoft C.E., 2004, Journal of Thermal Envelope and Building Science, V27, P327, DOI DOI 10.1177/1097196304042436
[6]   Moisture buffering capacity of heavy timber structures directly exposed to an indoor climate: a numerical study [J].
Hameury, S .
BUILDING AND ENVIRONMENT, 2005, 40 (10) :1400-1412
[7]  
HYGRO BAT, 2015, ANR10HABISOL00501 HY
[8]  
Kuenzel H.M., 2004, HTB042004E IBP
[9]   Numerical and experimental investigation of the hygrothermal response of timber frame walls with an exterior air barrier [J].
Langmans, Jelle ;
Klein, Ralf ;
Roels, Staf .
JOURNAL OF BUILDING PHYSICS, 2013, 36 (04) :375-397
[10]   Hygrothermal performance of wood-hemp insulation in timber frame wall panels with and without a vapour barrier [J].
Latif, Eshrar ;
Ciupala, Mihaela Anca ;
Tucker, Simon ;
Wijeyesekera, Devapriya Chitral ;
Newport, Darryl John .
BUILDING AND ENVIRONMENT, 2015, 92 :122-134