Rapid monitoring of grape withering using visible near-infrared spectroscopy

被引:31
|
作者
Beghi, Roberto [1 ]
Giovenzana, Valentina [1 ]
Marai, Simone [1 ]
Guidetti, Riccardo [1 ]
机构
[1] Univ Milan, Dept Agr & Environm Sci, Prod, Landscape,Agroenergy DiSAA, I-20133 Milan, Italy
关键词
grape withering; visible NIR spectroscopy; chemometrics; postharvest; soluble solids content; firmness; SOLUBLE SOLIDS CONTENT; WINE PRODUCTION; NONDESTRUCTIVE MEASUREMENT; REFLECTANCE SPECTROSCOPY; POSTHARVEST DEHYDRATION; NIR SPECTROSCOPY; QUALITY; WATER; CHEMOMETRICS; PREDICTION;
D O I
10.1002/jsfa.7053
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
BACKGROUNDWineries need new practical and quick instruments, non-destructive and able to quantitatively evaluate during withering the parameters that impact product quality. The aim of the work was to test an optical portable system (visible near-infrared (NIR) spectrophotometer) in a wavelength range of 400-1000nm for the prediction of quality parameters of grape berries during withering. RESULTSA total of 300 red grape samples (Vitis vinifera L., Corvina cultivar) harvested in vintage year 2012 from the Valpolicella area (Verona, Italy) were analyzed. Qualitative (principal component analysis, PCA) and quantitative (partial least squares regression algorithm, PLS) evaluations were performed on grape spectra. PCA showed a clear sample grouping for the different withering stages. PLS models gave encouraging predictive capabilities for soluble solids content (R-val(2)=0.62 and ratio performance deviation, RPD = 1.87) and firmness (R-val(2)=0.56 and RPD = 1.79). CONCLUSIONThe work demonstrated the applicability of visible NIR spectroscopy as a rapid technique for the analysis of grape quality directly in barns, during withering. The sector could be provided with simple and inexpensive optical systems that could be used to monitor the withering degree of grape for better management of the wine production process. (c) 2014 Society of Chemical Industry
引用
收藏
页码:3144 / 3149
页数:6
相关论文
共 50 条
  • [41] Rapid Nondestructive Detection of Water Content and Granulation in Postharvest "Shatian" Pomelo Using Visible/Near-Infrared Spectroscopy
    Xu, Sai
    Lu, Huazhong
    Ference, Christopher
    Qiu, Guangjun
    Liang, Xin
    BIOSENSORS-BASEL, 2020, 10 (04):
  • [42] Near-infrared spectroscopy for bioprocess monitoring and control
    Yeung, KSY
    Hoare, M
    Thornhill, NF
    Williams, T
    Vaghjiani, JD
    BIOTECHNOLOGY AND BIOENGINEERING, 1999, 63 (06) : 684 - 693
  • [43] Monitoring blood loss with near-infrared spectroscopy
    Torella, F
    Cowley, R
    McCollum, CN
    Thorniley, MS
    BRITISH JOURNAL OF SURGERY, 2001, 88 (05) : 753 - 753
  • [44] Implanted near-infrared spectroscopy for cardiac monitoring
    Bhunia, Sourav K.
    Cinbis, Can
    OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE IX, 2011, 7896
  • [45] Visible and near-infrared reflectance spectroscopy analysis of soils
    Ge, Yufeng
    Morgan, Cristine L. S.
    Wijewardane, Nuwan K.
    SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 2020, 84 (05) : 1495 - 1502
  • [46] Monitoring angiogenesis noninvasively with near-infrared spectroscopy
    University of Calgary, Experimental Imaging Centre, Faculty of Medicine, 3330 Hospital Drive NW, Calgary, AB T2N 4N1, Canada
    不详
    不详
    不详
    不详
    J Biomed Opt, 2008, 6
  • [47] Monitoring angiogenesis noninvasively with near-infrared spectroscopy
    Dunn, Jeffrey F.
    Zhang, Qiong
    Wu, Ying
    Srinivasan, Sathyanarayanan
    Smith, Michael R.
    Shaw, R. Anthony
    JOURNAL OF BIOMEDICAL OPTICS, 2008, 13 (06)
  • [48] Cerebral oxygenation monitoring: near-infrared spectroscopy
    Tobias, Joseph D.
    EXPERT REVIEW OF MEDICAL DEVICES, 2006, 3 (02) : 235 - 243
  • [49] Near-infrared spectroscopy for monitoring muscle oxygenation
    Boushel, R
    Piantadosi, CA
    ACTA PHYSIOLOGICA SCANDINAVICA, 2000, 168 (04): : 615 - 622
  • [50] Usefulness of near-infrared spectroscopy in thrombectomy monitoring
    Thomas Ritzenthaler
    Tae-Hee Cho
    David Luis
    Yves Berthezene
    Norbert Nighoghossian
    Journal of Clinical Monitoring and Computing, 2015, 29 : 585 - 589