Relationships between PCA and PLS-regression

被引:75
作者
Godoy, Jose L. [1 ,2 ,3 ]
Vega, Jorge R. [1 ,2 ,4 ]
Marchetti, Jacinto L. [1 ,2 ]
机构
[1] Consejo Nacl Invest Cient & Tecn, INTEC, RA-3000 Santa Fe, Argentina
[2] Univ Nacl Litoral, RA-3000 Santa Fe, Argentina
[3] Univ Tecnol Nacl, Fac Reg Parana, RA-3100 Parana, Argentina
[4] Univ Tecnol Nacl, Fac Reg Santa Fe, RA-3000 Santa Fe, Argentina
关键词
PLS-regression; PCA; Latent models; Prediction models; Fault detection indices; PARTIAL LEAST-SQUARES; STATISTICAL PROCESS-CONTROL; DIAGNOSIS;
D O I
10.1016/j.chemolab.2013.11.008
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This work aims at comparing several features of Principal Component Analysis (PCA) and Partial Least Squares Regression (PLSR), as techniques typically utilized for modeling, output prediction, and monitoring of multivariate processes. First, geometric properties of the decomposition induced by PLSR are described in relation to the PCA of the separated input and output data (X-PCA and Y-PCA, respectively). Then, analogies between the models derived with PLSR and YX-PCA (i.e., PCA of the joint input-output variables) are presented; and regarding to process monitoring applications, the specific PLSR and YX-PCA fault detection indices are compared. Numerical examples are used to illustrate the relationships between latent models, output prediction models, and fault detection indices. The three alternative approaches (PLSR, YX-PCA and Y-PCA plus X-PCA) are compared with regard to their use for statistical modeling. In particular, a case study is simulated and the results are used for enhancing the comprehension of the PLSR properties and for evaluating the discriminatory capacity of the fault detection indices based on the PLSR and YX-PCA modeling alternatives. Some recommendations are given in order to choose the more appropriate approach for a specific application: 1) PLSR and YX-PCA have similar capacity for fault detection, but PLSR is recommended for process monitoring because it presents a better diagnosing capability; 2) PLSR is more reliable for output prediction purposes (e.g., for soft sensor development); and 3) YX-PCA is recommended for the analysis of latent patterns imbedded in datasets. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:182 / 191
页数:10
相关论文
共 28 条
[11]   Latent Variable Model Predictive Control (LV-MPC) for trajectory tracking in batch processes [J].
Golshan, Masoud ;
MacGregor, John F. ;
Bruwer, Mark-John ;
Mhaskar, Prashant .
JOURNAL OF PROCESS CONTROL, 2010, 20 (04) :538-550
[12]  
Hoskuldsson A., 1988, Journal of Chemometrics, V2, P211, DOI DOI 10.1002/CEM.1180020306
[13]   A comparison of various methods for multivariate regression with highly collinear variables [J].
Kiers, Henk A. L. ;
Smilde, Age K. .
STATISTICAL METHODS AND APPLICATIONS, 2007, 16 (02) :193-228
[14]   Application of latent variable methods to process control and multivariate statistical process control in industry [J].
Kourti, T .
INTERNATIONAL JOURNAL OF ADAPTIVE CONTROL AND SIGNAL PROCESSING, 2005, 19 (04) :213-246
[15]   Cyclic subspace regression [J].
Lang, PM ;
Brenchley, JM ;
Nieves, RG ;
Kalivas, JH .
JOURNAL OF MULTIVARIATE ANALYSIS, 1998, 65 (01) :58-70
[16]   Data-driven latent-variable model-based predictive control for continuous processes [J].
Lauri, D. ;
Rossiter, J. A. ;
Sanchis, J. ;
Martinez, M. .
JOURNAL OF PROCESS CONTROL, 2010, 20 (10) :1207-1219
[17]   Statistical process monitoring with independent component analysis [J].
Lee, JM ;
Yoo, CK ;
Lee, IB .
JOURNAL OF PROCESS CONTROL, 2004, 14 (05) :467-485
[18]   Geometric properties of partial least squares for process monitoring [J].
Li, Gang ;
Qin, S. Joe ;
Zhou, Donghua .
AUTOMATICA, 2010, 46 (01) :204-210
[19]   Monitoring, fault diagnosis, fault-tolerant control and optimization: Data driven methods [J].
MacGregor, John ;
Cinar, Ali .
COMPUTERS & CHEMICAL ENGINEERING, 2012, 47 :111-120
[20]   Model predictive statistical process control of chemical plants [J].
McAvoy, T .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2002, 41 (25) :6337-6344