EMAT phased array: A feasibility study of surface crack detection

被引:51
作者
Isla, J. [1 ]
Cegla, F. [1 ]
机构
[1] Imperial Coll London, Dept Mech Engn, London SW7 2AZ, England
基金
英国工程与自然科学研究理事会;
关键词
EMAT; Ultrasonic arrays; Low-SNR; Coded sequences; Pulse-compression; NDE; Material inspection; ELECTROMAGNETIC ACOUSTIC TRANSDUCERS; ULTRASONIC ARRAY; NONDESTRUCTIVE EVALUATION; RAYLEIGH-WAVE; FULL-MATRIX; PROPAGATION; IMPROVEMENT; INSPECTION; DEFECTS;
D O I
10.1016/j.ultras.2017.02.009
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Electromagnetic-acoustic transducers (EMATs) consist of a magnet and a coil. They are advantageous in some non-destructive evaluation (NDE) applications because no direct contact with the specimen is needed to send and receive ultrasonic waves. However, EMATs commonly require excitation peak powers greater than 1 kW and therefore the driving electronics and the EMAT coils have to be bulky. This has hindered the development of EMAT phased arrays with characteristics similar to those of conventional piezoelectric phased arrays. Phased arrays are widely used in NDE because they offer superior defect characterization in comparison to single-element transducers. In this paper, we report a series of novel techniques and design elements that make it possible to construct an EMAT phased array that performs similarly to conventional piezoelectric arrays used in NDE. One of the key enabling features is the use of coded excitation to reduce the excitation peak power to less than 4.8 W (24 Vpp and 200 mA) so that racetrack coils with dimensions 3.2 x 18 mm(2) can be employed. Moreover, these racetrack coils are laid out along their shortest dimension so that 1/3 of their area is overlapped. This helps to reduce the crosstalk between the coils, i.e., the array elements, to less than 15 dB. We show that an 8-element EMAT phased array operating at a central frequency of 1 MHz can be used to detect defects which have a width and a depth of 0.2 and 0.8 mm respectively and are located on the surface opposite to the array. (C) 2017 The Authors. Published by Elsevier B.V.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 41 条
[1]   Complete noncontact laser ultrasonic imaging for automated crack visualization in a plate [J].
An, Yun-Kyu ;
Park, Byeongjin ;
Sohn, Hoon .
SMART MATERIALS AND STRUCTURES, 2013, 22 (02)
[2]   Signal enhancement in Rayleigh wave interactions using a laser-ultrasound/EMAT imaging system [J].
Boonsang, S ;
Dewhurst, RJ .
ULTRASONICS, 2005, 43 (07) :512-523
[3]   Fourier-Domain Beamforming: The Path to Compressed Ultrasound Imaging [J].
Chernyakova, Tanya ;
Eldar, Yonina C. .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2014, 61 (08) :1252-1267
[4]   Practical experience of phased array technology for power station applications [J].
Crowther, P .
INSIGHT, 2004, 46 (09) :525-528
[5]  
Dobbs ER., 2012, PHYS ACOUSTICS, V10, P127
[6]   Ultrasonic arrays for non-destructive evaluation: A review [J].
Drinkwater, Bruce W. ;
Wilcox, Paul D. .
NDT & E INTERNATIONAL, 2006, 39 (07) :525-541
[7]   Ultrasonic surface wave propagation and interaction with surface defects on rail track head [J].
Fan, Y. ;
Dixon, S. ;
Edwards, R. S. ;
Jian, X. .
NDT & E INTERNATIONAL, 2007, 40 (06) :471-477
[8]   Nonintrusive Estimation of Anisotropic Stiffness Maps of Heterogeneous Steel Welds for the Improvement of Ultrasonic Array Inspection [J].
Fan, Zheng ;
Mark, Alison F. ;
Lowe, Michael J. S. ;
Withers, Philip J. .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2015, 62 (08) :1530-1543
[9]   Accurate depth measurement of small surface-breaking cracks using an ultrasonic array post-processing technique [J].
Felice, Maria V. ;
Velichko, Alexander ;
Wilcox, Paul D. .
NDT & E INTERNATIONAL, 2014, 68 :105-112
[10]   Generalized pairwise Z-complementary codes [J].