Does cross-linked polyethylene decrease the revision rate of total hip arthroplasty compared with conventional polyethylene? A meta-analysis

被引:35
作者
Shen, C. [1 ]
Tang, Z. -H. [1 ]
Hu, J. -Z. [1 ]
Zou, G. -Y. [1 ]
Xiao, R. -C. [1 ]
Yan, D. -X. [1 ]
机构
[1] Guilin Med Coll, Affiliated Hosp, Dept Orthoped, Guilin 541001, Guangxi, Peoples R China
关键词
Total hip arthroplasty; Polyethylene; Cross-linked; Meta-analysis; MOLECULAR-WEIGHT POLYETHYLENE; CEMENTED THA; DOUBLE-BLIND; WEAR RATE; IN-VIVO; OSTEOLYSIS; LINKING; REPLACEMENT; OUTCOMES; BEARING;
D O I
10.1016/j.otsr.2014.07.015
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Although cross-linked polyethylene is resistant to wear in comparison to conventional polyethylene, it remains unknown whether it can decrease the wear-related revision rate of total hip arthroplasty. Objectives: To determine whether cross-linked polyethylene decreases the wear-related revision rate of total hip arthroplasty compared with conventional polyethylene. Data sources: Electronic databases, including PubMed, EMBASE, and the Cochrane Central Register of Controlled Trials, were queried from inception to July 6, 2013. Study selection: Randomized controlled trials (RCTs) comparing cross-linked polyethylene with conventional polyethylene were included. In addition, the standard 28-mm femoral head was used, and follow-up was performed for a minimum of 5 years. The primary outcome assessed was wear-related revision. The secondary outcome measures evaluated were the incidence of osteolysis, the linear wear rate, and the linear head penetration. Data synthesis: The Cochrane Collaboration's tool for assessing the risk of bias was used for quality assessment. Data from eligible studies were pooled using a random effects model. Results: Eight studies involving 735 patients were included in this study. Meta-analysis showed there was no significant difference between cross-linked and conventional polyethylene group in terms of osteolysis or wear-related revision. The pooled mean differences were significantly less for the linear wear rate and linear head penetration for cross-linked polyethylene than for conventional polyethylene. Limitations: The studies differed with respect to the cross-linked liner brands, manufacturing processes, and radiological evaluation methods. Moreover, the follow-up periods of the RCTs were not long enough. Conclusions: The current limited evidence suggests that cross-linked polyethylene significantly reduced the radiological wear compared with conventional polyethylene at midterm follow-up periods. However, there is no evidence that cross-linked polyethylene had an advantage over conventional polyethylene in terms of reducing osteolysis or wear-related revision. Nevertheless, future long-term RCTs on this topic are needed. Key findings: Cross-linked polyethylene significantly reduced radiological wear but not osteolysis or wear-related revision in comparison to conventional polyethylene at midterm follow-up periods. (C) 2014 Published by Elsevier Masson SAS.
引用
收藏
页码:745 / 750
页数:6
相关论文
共 39 条
[1]   Metal-on-metal bearing in hip prosthesis generates 100-fold less wear debris than metal-on-polyethylene [J].
Anissian, HL ;
Stark, A ;
Gustafson, A ;
Good, V ;
Clarke, IC .
ACTA ORTHOPAEDICA SCANDINAVICA, 1999, 70 (06) :578-582
[2]   The effects of degree of crosslinking on the fatigue crack initiation and propagation resistance of orthopedic-grade polyethylene [J].
Baker, DA ;
Bellare, A ;
Pruitt, L .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2003, 66A (01) :146-154
[3]  
Bizot P, 2001, CLIN ORTHOP RELAT R, P85
[4]   A Double-Blind, Prospective, Randomized Controlled Trial Comparing Highly Cross-Linked and Conventional Polyethylene in Primary Total Hip Arthroplasty [J].
Calvert, George T. ;
Devane, Peter A. ;
Fielden, Jan ;
Adams, Kathryn ;
Horne, J. Geoffrey .
JOURNAL OF ARTHROPLASTY, 2009, 24 (04) :505-510
[5]   Ten-year survivorship of the Anatomique Benoist Girard I total hip arthroplasty [J].
Castoldi, Filippo ;
Rossi, Roberto ;
La Russa, Massimo ;
Sibelli, Pierro ;
Rossi, Paolo ;
Ranawat, Amar S. .
JOURNAL OF ARTHROPLASTY, 2007, 22 (03) :363-368
[6]  
Cross Michael B, 2012, HSS J, V8, P270, DOI 10.1007/s11420-012-9287-7
[7]   Highly cross-linked polyethylene in cemented THA -: Randomized study of 61 hips [J].
Digas, G ;
Kärrholm, J ;
Thanner, J ;
Malchau, H ;
Herberts, P .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (417) :126-138
[8]   A literature review of the association between wear rate and osteolysis in total hip arthroplasty [J].
Dumbleton, JH ;
Manley, MT ;
Edidin, AA .
JOURNAL OF ARTHROPLASTY, 2002, 17 (05) :649-661
[9]   A Prospective, Randomized Study of Cross-Linked and Non-Cross-Linked Polyethylene for Total Hip Arthroplasty at 10-Year Follow-Up [J].
Engh, Charles A., Jr. ;
Hopper, Robert H., Jr. ;
Huynh, Cathy ;
Ho, Henry ;
Sritulanondha, Supatra ;
Engh, Charles A., Sr. .
JOURNAL OF ARTHROPLASTY, 2012, 27 (08) :2-7
[10]   New polyethylenes in total hip replacement A TEN- TO 12-YEAR FOLLOW-UP STUDY [J].
Garcia-Rey, E. ;
Garcia-Cimbrelo, E. ;
Cruz-Pardos, A. .
BONE & JOINT JOURNAL, 2013, 95B (03) :326-332