The accuracy of femoral intramedullary guides in total knee arthroplasty

被引:109
作者
Reed, SC
Gollish, J
机构
[1] Orthpaedic and Arthritic Hospital, Toronto, Ont.
[2] Orthopaedic and Arthritic Hospital, Toronto, Ont. M4Y 1H1
关键词
intramedullary guide; total knee arthroplasty; anatomic axis; entry point;
D O I
10.1016/S0883-5403(97)90141-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Of the technical factors important in achieving a successful total knee arthroplasty, limb alignment has been demonstrated to be most influential in determining implant survival. Intramedullary femoral guide systems rely on placement of the intramedullary rod along the anatomic axis of the femur. Ln this article, the accuracy of the femoral intramedullary guide is investigated using radiographs and a mathematical model. The femoral anatomic axis was drawn on 40 consecutive, preoperative, 3-ft standing radiographs. Using a mathematical model, the potential angular error in the distal femoral cut from aberrant placement of the intramedullary rod was estimated. Calculated values correlated with measured values from plain radiographs and an intramedullary guide template. The anatomic axis was found to exit the distal femur at an average of 6.6 mm medial to the center of the femoral notch. Substantial malalignment error resulted from minor malposition of the intramedullary rod. Most books and diagrams demonstrating the use of intramedullary guides indicate that the entry point is at the center of the femoral notch. These results show that the true entry point is medial to the center of the notch, and rod placement error results in excessive valgus alignment. Preoperative drawing of the anatomic axis on a 3-ft or 18-inch anteroposterior radiograph is recommended. The results both demonstrate the importance of correct use of the guide and heighten cognizance among surgeons performing total knee arthroplasty as to the limitations of the intramedullary guides.
引用
收藏
页码:677 / 682
页数:6
相关论文
共 50 条
  • [41] Comparison of three methods for sealing of the intramedullary femoral canal during total knee arthroplasty; a randomized controlled trial
    İsmail Dikmen
    Ozkan Kose
    Albert Cakar
    Ersin Tasatan
    Mehmet Barıs Ertan
    Dilek Yapar
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 3309 - 3317
  • [42] Computerized tomography scout view for determining distal femoral resection angle in intramedullary instrumentation of total knee arthroplasty
    Uslu, M. Murad
    Ozsar, Baris
    Cirpar, Meric
    Kara, Simay
    Eksioglu, Fatih
    Cetik, Ozgur
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2007, 15 (01) : 78 - 82
  • [43] Comparison of three methods for sealing of the intramedullary femoral canal during total knee arthroplasty; a randomized controlled trial
    Dikmen, Ismail
    Kose, Ozkan
    Cakar, Albert
    Tasatan, Ersin
    Ertan, Mehmet Baris
    Yapar, Dilek
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (06) : 3309 - 3317
  • [44] An Innovative Three-Dimensional Method for Identifying a Proper Femoral Intramedullary Entry Point in Total Knee Arthroplasty
    Ma, Lu-Yao
    Wei, Hong-Yu
    Wan, Fu-Yin
    Guo, Wan-Shou
    Ma, Jin-Hui
    CHINESE MEDICAL JOURNAL, 2018, 131 (21) : 2531 - 2536
  • [45] Accuracy of Femoral Component External Rotation with all Burr Robotic Assisted Total Knee Arthroplasty
    Laddha, M. S.
    Gowtam, S., V
    Jain, P.
    MALAYSIAN ORTHOPAEDIC JOURNAL, 2024, 18 (01) : 19 - 25
  • [46] Computerized tomography scout view for determining distal femoral resection angle in intramedullary instrumentation of total knee arthroplasty
    M. Murad Uslu
    Baris Ozsar
    Meric Cirpar
    Simay Kara
    Fatih Eksioglu
    Ozgur Cetik
    Knee Surgery, Sports Traumatology, Arthroscopy, 2007, 15 : 78 - 82
  • [47] Patient specific guides for total knee arthroplasty are ready for primetime
    Schotanus, Martijn G. M.
    Boonen, Bert
    Kort, Nanne P.
    WORLD JOURNAL OF ORTHOPEDICS, 2016, 7 (01): : 61 - 68
  • [48] Fracture of femoral component in a resurfacing total knee arthroplasty
    Michos, John
    Rallis, John
    Fassoulas, Apostolos
    JOURNAL OF ARTHROPLASTY, 2006, 21 (07) : 1068 - 1071
  • [49] Femoral sizing in total knee arthroplasty is rotation dependant
    Koninckx, Angelique
    Deltour, Arnaud
    Thienpont, Emmanuel
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (12) : 2941 - 2946
  • [50] Femoral sizing in total knee arthroplasty is rotation dependant
    Angelique Koninckx
    Arnaud Deltour
    Emmanuel Thienpont
    Knee Surgery, Sports Traumatology, Arthroscopy, 2014, 22 : 2941 - 2946