The accuracy of femoral intramedullary guides in total knee arthroplasty

被引:109
|
作者
Reed, SC
Gollish, J
机构
[1] Orthpaedic and Arthritic Hospital, Toronto, Ont.
[2] Orthopaedic and Arthritic Hospital, Toronto, Ont. M4Y 1H1
关键词
intramedullary guide; total knee arthroplasty; anatomic axis; entry point;
D O I
10.1016/S0883-5403(97)90141-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Of the technical factors important in achieving a successful total knee arthroplasty, limb alignment has been demonstrated to be most influential in determining implant survival. Intramedullary femoral guide systems rely on placement of the intramedullary rod along the anatomic axis of the femur. Ln this article, the accuracy of the femoral intramedullary guide is investigated using radiographs and a mathematical model. The femoral anatomic axis was drawn on 40 consecutive, preoperative, 3-ft standing radiographs. Using a mathematical model, the potential angular error in the distal femoral cut from aberrant placement of the intramedullary rod was estimated. Calculated values correlated with measured values from plain radiographs and an intramedullary guide template. The anatomic axis was found to exit the distal femur at an average of 6.6 mm medial to the center of the femoral notch. Substantial malalignment error resulted from minor malposition of the intramedullary rod. Most books and diagrams demonstrating the use of intramedullary guides indicate that the entry point is at the center of the femoral notch. These results show that the true entry point is medial to the center of the notch, and rod placement error results in excessive valgus alignment. Preoperative drawing of the anatomic axis on a 3-ft or 18-inch anteroposterior radiograph is recommended. The results both demonstrate the importance of correct use of the guide and heighten cognizance among surgeons performing total knee arthroplasty as to the limitations of the intramedullary guides.
引用
收藏
页码:677 / 682
页数:6
相关论文
共 50 条
  • [1] Angle Accuracy of Intramedullary Bone Resection Guides for Total Knee Arthroplasty
    Kane, Matthew C.
    Cates, Harold E.
    Chang, Iou-Ren
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (09)
  • [2] The accuracy of the extramedullary and intramedullary femoral alignment system in total knee arthroplasty for varus osteoarthritic knee
    Jung, Woon-hwa
    Chun, Chung-woo
    Lee, Ji-hoon
    Ha, Jae-hun
    Jeong, Jae-Heon
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (03) : 629 - 635
  • [3] The accuracy of the extramedullary and intramedullary femoral alignment system in total knee arthroplasty for varus osteoarthritic knee
    Woon-hwa Jung
    Chung-woo Chun
    Ji-hoon Lee
    Jae-hun Ha
    Jae-Heon Jeong
    Knee Surgery, Sports Traumatology, Arthroscopy, 2013, 21 : 629 - 635
  • [4] Intramedullary versus extramedullary tibial alignment guides in total knee arthroplasty
    Yang, SH
    Liu, TK
    JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 1998, 97 (08) : 564 - 568
  • [5] Assessing the accuracy of patient-specific guides for total knee arthroplasty
    Seon, Jong-Keun
    Park, Hyeong-Won
    Yoo, Seung-Hyun
    Song, Eun-Kyoo
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2016, 24 (11) : 3678 - 3683
  • [6] The accuracy of extramedullary guides for tibial component placement in total knee arthroplasty
    K. Y. Chiu
    W. P. Yau
    T. P. Ng
    W. M. Tang
    International Orthopaedics, 2008, 32 : 467 - 471
  • [7] Prophylactic intramedullary femoral rodding during total knee arthroplasty with simultaneous femoral plate removal
    Ries, MD
    JOURNAL OF ARTHROPLASTY, 1998, 13 (06) : 718 - 721
  • [8] Assessing the accuracy of patient-specific guides for total knee arthroplasty
    Jong-Keun Seon
    Hyeong-Won Park
    Seung-Hyun Yoo
    Eun-Kyoo Song
    Knee Surgery, Sports Traumatology, Arthroscopy, 2016, 24 : 3678 - 3683
  • [9] Intramedullary versus extramedullary alignment guides on total knee arthroplasty: a meta-analysis
    Qin, Ya-fei
    Li, Na
    Shi, Yong-xin
    Sun, Kai
    Li, Zhi-jun
    Li, Hui
    JOURNAL OF COMPARATIVE EFFECTIVENESS RESEARCH, 2018, 7 (12) : 1181 - 1193
  • [10] Unusual complication associated with femoral intramedullary alignment guide in total knee arthroplasty
    Yau, WP
    Ng, TP
    Chiu, KY
    JOURNAL OF ARTHROPLASTY, 2001, 16 (02) : 247 - 249