Determination of moisture content in a deformable soil using time-domain reflectometry (TDR)

被引:13
|
作者
Kim, DJ
Choi, SI
Ryszard, O
Feyen, J
Kim, HS
机构
[1] Korea Univ, Fac Sci, Dept Earth & Environm Sci, Seoul, South Korea
[2] Kwang Woon Univ, Fac Engn, Dept Environm Engn, Seoul, South Korea
[3] Agr Univ Warsaw, Dept Land & Forest Reclamat, PL-02767 Warsaw, Poland
[4] Katholieke Univ Leuven, Inst Land & Water Management, B-3000 Louvain, Belgium
关键词
D O I
10.1046/j.1365-2389.2000.00284.x
中图分类号
S15 [土壤学];
学科分类号
0903 ; 090301 ;
摘要
Time-domain reflectometry (TDR) is being used increasingly for measuring the moisture content of porous media. However, successful application for measuring water in soil has been limited to non-deformable soils, and it would be a valuable extension of the technique if it could be used for soils that shrink on drying. We have recently investigated its application to soils rich in clay and organic matter and peats. Here we propose a method for determining moisture content in deformable soils based on the relation between the dielectric constant, K, and the volumetric moisture content, Theta, measured by TDR. Parallel TDR probes with a length of 15 cm and a spacing of 2 cm were placed horizontally in soil cores with a diameter of 20 cm and height of 10 cm taken from a forest. The soil is very porous with large proportions of both silt and clay. The sample weight and travel time of the electromagnetic wave guided by parallel TDR probes were simultaneously measured as a function of time, from saturation to oven-dryness during which the core samples shrank considerably. Vertical and horizontal components of shrinkage were also measured to take the air-exposed region of TDR probe into account in the determination of K. The effect of deformation on volumetric moisture content was formulated for two different expressions, namely actual volumetric moisture content (AVMC) and fictitious (uncorrected) volumetric moisture content (FVMC). The effects of air-exposure and expressions of volumetric moisture content on the relation between K and Theta were examined by fitting the observations with a third-order polynomial. Neglecting the travel time in the air-exposed part or use of the FVMC underestimated the Theta for a given K. The difference was more pronounced between AVMC and FVMC than between two different dielectric constants, i.e. accounting for air-exposure, K-ac, and not accounting for air-exposure, K-au. When the existing empirical models were compared with the fitted results, most underestimated the relation based on the AVMC. This indicates that published empirical models do not reflect the effect of deformation on the determination of Theta in our forest soil. Correct use of the Theta expression has more impact on determining moisture content of a deformable soil than the accommodation of travel time through the air-exposed region of TDR probe.
引用
收藏
页码:119 / 127
页数:9
相关论文
共 50 条
  • [1] Measurement of soil water content using time-domain reflectometry (TDR)
    Chudinova, SM
    Ponizovskii, AA
    Shcherbakov, RA
    EURASIAN SOIL SCIENCE, 1996, 29 (10) : 1177 - 1183
  • [2] Measuring water content of soil substitutes with time-domain reflectometry (TDR)
    da Silva, FF
    Wallach, R
    Polak, A
    Chen, Y
    JOURNAL OF THE AMERICAN SOCIETY FOR HORTICULTURAL SCIENCE, 1998, 123 (04) : 734 - 737
  • [3] Soil moisture in Pernambuco semiarid using time domain reflectometry (TDR)
    dos Santos, Thais E. M.
    Montenegro, Abelardo A. A.
    Silva, Demetrius D.
    REVISTA BRASILEIRA DE ENGENHARIA AGRICOLA E AMBIENTAL, 2011, 15 (07): : 670 - 679
  • [4] Determination of moisture diffusivity using the time domain reflectometry (TDR) method
    Pavlik, Zbysek
    Jirickova, Milena
    Cerny, Robert
    Sobczuk, Henryk
    Suchorab, Zbigniew
    JOURNAL OF BUILDING PHYSICS, 2006, 30 (01) : 59 - 70
  • [5] CONSIDERATIONS ON THE USE OF TIME-DOMAIN REFLECTOMETRY (TDR) FOR MEASURING SOIL-WATER CONTENT
    WHALLEY, WR
    JOURNAL OF SOIL SCIENCE, 1993, 44 (01): : 1 - 9
  • [6] The effect of soil electrical conductivity on moisture determination using time-domain reflectometry in sandy soil
    Sun, ZJ
    Young, GD
    McFarlane, RA
    Chambers, BM
    CANADIAN JOURNAL OF SOIL SCIENCE, 2000, 80 (01) : 13 - 22
  • [7] Control of the moisture content of growing media by time domain reflectometry (TDR)
    Morel, P
    Michel, JC
    AGRONOMIE, 2004, 24 (05): : 275 - 279
  • [8] CONSIDERATIONS ON THE USE OF TIME-DOMAIN REFLECTOMETRY (TDR) FOR MEASURING SOIL-WATER CONTENT - COMMENT
    WHITE, I
    KNIGHT, JH
    ZEGELIN, SJ
    TOPP, GC
    EUROPEAN JOURNAL OF SOIL SCIENCE, 1994, 45 (04) : 503 - 508
  • [9] Modeling and Monitoring of Wood Moisture Content Using Time-Domain Reflectometry
    Dahlen, Joseph
    Schimleck, Laurence
    Schilling, Erik
    FORESTS, 2020, 11 (04):
  • [10] APPLICATION OF TIME-DOMAIN REFLECTOMETRY (TDR) SOIL-MOISTURE MINIPROBE FOR THE DETERMINATION OF UNSATURATED SOIL-WATER CHARACTERISTICS FROM UNDISTURBED SOIL CORES
    MALICKI, MA
    PLAGGE, R
    RENGER, M
    WALCZAK, RT
    IRRIGATION SCIENCE, 1992, 13 (02) : 65 - 72