Accuracy of Wearable Transdermal Alcohol Sensors: Systematic Review

被引:22
作者
Brobbin, Eileen [1 ]
Deluca, Paolo [1 ]
Hemrage, Sofia [1 ]
Drummond, Colin [1 ]
机构
[1] Kings Coll London, Dept Addict, Addict Sci Bldg,4 Windsor Walk, London SE5 8BB, England
关键词
alcohol consumption; alcohol detection; alcohol monitoring; alcohol treatment; digital technology; ecologic momentary assessment; transdermal alcohol sensors; wearables; mobile phone; CONTINGENCY MANAGEMENT; BREATH ALCOHOL; USE REDUCTION; SELF-REPORT; CONSUMPTION; DRINKING; VALIDITY;
D O I
10.2196/35178
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background: There are a range of wearable transdermal alcohol sensors that are available and are being developed. These devices have the potential to monitor alcohol consumption continuously over extended periods in an objective manner, overcoming some of the limitations of other alcohol measurement methods (blood, breath, and urine). Objective: The objective of our systematic review was to assess wearable transdermal alcohol sensor accuracy. Methods: A systematic search of the CINAHL, Embase, Google Scholar, MEDLINE, PsycINFO, PubMed, and Scopus bibliographic databases was conducted in February 2021. In total, 2 team members (EB and SH) independently screened studies for inclusion, extracted data, and assessed the risk of bias. The methodological quality of each study was appraised using the Mixed Methods Appraisal Tool. The primary outcome was transdermal alcohol sensor accuracy. The data were presented as a narrative synthesis. Results: We identified and analyzed 32 studies. Study designs included laboratory, ambulatory, and mixed designs, as well as randomized controlled trials; the length of time for which the device was worn ranged from days to weeks; and the analyzed sample sizes ranged from 1 to 250. The results for transdermal alcohol concentration data from various transdermal alcohol sensors were generally found to positively correlate with breath alcohol concentration, blood alcohol concentration, and self-report (moderate to large correlations). However, there were some discrepancies between study reports; for example, WrisTAS sensitivity ranged from 24% to 85.6%, and specificity ranged from 67.5% to 92.94%. Higher malfunctions were reported with the BACtrack prototype (16%-38%) and WrisTAS (8%) than with SCRAM (2%); however, the former devices also reported a reduced time lag for peak transdermal alcohol concentration values when compared with SCRAM. It was also found that many companies were developing new models of wearable transdermal alcohol sensors. Conclusions: As shown, there is a lack of consistency in the studies on wearable transdermal alcohol sensor accuracy regarding study procedures and analyses of findings, thus making it difficult to draw direct comparisons between them. This needs to be considered in future research, and there needs to be an increase in studies directly comparing different transdermal alcohol sensors. There is also a lack of research investigating the accuracy of transdermal alcohol sensors as a tool for monitoring alcohol consumption in clinical populations and use over extended periods. Although there is some preliminary evidence suggesting the accuracy of these devices, this needs to be further investigated in clinical populations.
引用
收藏
页数:14
相关论文
共 54 条
[1]   Objective continuous monitoring of alcohol consumption for three months among alcohol use disorder treatment outpatients [J].
Alessi, Sheila M. ;
Barnett, Nancy P. ;
Petry, Nancy M. .
ALCOHOL, 2019, 81 :131-138
[2]   STATISTICS NOTES - DIAGNOSTIC-TESTS-1 - SENSITIVITY AND SPECIFICITY .3. [J].
ALTMAN, DG ;
BLAND, JM .
BRITISH MEDICAL JOURNAL, 1994, 308 (6943) :1552-1552
[3]  
[Anonymous], 2021, OFF BE BANN DRINK CU
[4]  
[Anonymous], 2004, NIAAA COUNC APPR DEF
[5]   Quantitative Determination of Caffeine and Alcohol in Energy Drinks and the Potential to Produce Positive Transdermal Alcohol Concentrations in Human Subjects [J].
Ayala, Jessica ;
Simons, Kelsie ;
Kerrigan, Sarah .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2009, 33 (01) :27-33
[6]   A preliminary randomized controlled trial of contingency management for alcohol use reduction using a transdermal alcohol sensor [J].
Barnett, Nancy P. ;
Celio, Mark A. ;
Tidey, Jennifer W. ;
Murphy, James G. ;
Colby, Suzanne M. ;
Swift, Robert M. .
ADDICTION, 2017, 112 (06) :1025-1035
[7]   Alcohol sensors and their potential for improving clinical care [J].
Barnett, Nancy P. .
ADDICTION, 2015, 110 (01) :1-3
[8]   Predictors of Detection of Alcohol Use Episodes Using a Transdermal Alcohol Sensor [J].
Barnett, Nancy P. ;
Meade, E. B. ;
Glynn, Tiffany R. .
EXPERIMENTAL AND CLINICAL PSYCHOPHARMACOLOGY, 2014, 22 (01) :86-96
[9]   Contingency management for alcohol use reduction: A pilot study using a transdermal alcohol sensor [J].
Barnett, Nancy P. ;
Tidey, Jennifer ;
Murphy, James G. ;
Swift, Robert ;
Colby, Suzanne M. .
DRUG AND ALCOHOL DEPENDENCE, 2011, 118 (2-3) :391-399
[10]   Combining ecological momentary assessment with objective, ambulatory measures of behavior and physiology in substance-use research [J].
Bertz, Jeremiah W. ;
Epstein, David H. ;
Preston, Kenzie L. .
ADDICTIVE BEHAVIORS, 2018, 83 :5-17