Numerical study of a ventilation system based on wall confluent jets

被引:15
作者
Janbakhsh, Setareh [1 ,2 ]
Moshfegh, Bahram [1 ,2 ]
机构
[1] Linkoping Univ, Dept Management & Engn, SE-58183 Linkoping, Sweden
[2] Univ Gavle, Dept Bldg Energy & Environm Engn, SE-80176 Gavle, Sweden
来源
HVAC&R RESEARCH | 2014年 / 20卷 / 08期
关键词
COMPUTATIONAL FLUID-DYNAMICS; K-EPSILON MODELS; INDOOR AIR-FLOW; TURBULENCE MODELS; INDUSTRIAL PREMISES; FIELD-MEASUREMENTS; SUPPLY-SYSTEMS; TEST ROOM; ENVIRONMENTS; PREDICTIONS;
D O I
10.1080/10789669.2014.957111
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study presents numerical investigation of an air supply device based on wall confluent jets in a ventilated room. Confluent jets can be described as multiple round jets issuing from supply device apertures. The jets converge, merge, and combine at a certain distance downstream from the supply device and behave as a united jet, or so-called confluent jet. The numerical predictions of the velocity flow field of isothermal confluent jets with three Reynolds-averaged Navier-Stokes turbulence models (renormalization group k-epsilon, realizable k-epsilon, and shear stress transport k-omega) are reported in the present study. The results of the numerical predictions are verified with detailed experimental measurements by a hot wire anemometer and constant temperature anemometers for two airflow rates. The box method is used to provide the inlet boundary conditions. The study of the airflow distribution shows that a primary wall jet (wall confluent jet) exists close to the supply device along the wetted wall, and a secondary wall jet is created after the stagnation region along the floor. It is presented that the flow field of the primary and secondary wall jet predicted by turbulence models is in good agreement with the experimental data. The current study is also compared with the literature in terms of velocity decay and the spreading rate of the primary and secondary wall jet, the results of which are consistent with each other. Velocity decay and the spreading rate of the secondary wall jet in vertical and lateral directions were studied for different inlet airflow rates and inlet discharge heights. The comparative results demonstrate that the flow behavior is nearly independent of the inlet flow rate. Inlet discharge height is found to have impact close to the inlet, where the velocity decays faster when the jet discharges at higher level. The decay tendency is similar as the jet enters into the room for all discharge heights.
引用
收藏
页码:846 / 861
页数:16
相关论文
共 43 条
[1]  
[Anonymous], 1986, J. Sci. Comput.
[2]  
ANSYS, 2010, ANS WORKB 13 0 US GU
[3]  
ANSYS, 2010, ANS 13 0 FLUENT THEO
[4]  
ASHRAE, 2009, ASHR HDB IND ENV MOD, P13
[5]   APPLICATION OF COMPUTATIONAL FLUID-DYNAMICS IN ROOM VENTILATION [J].
AWBI, HB .
BUILDING AND ENVIRONMENT, 1989, 24 (01) :73-84
[6]  
BAKER AJ, 1994, ASHRAE T, V100, P514
[7]   Prediction of room air motion by Reynolds-Stress models [J].
Chen, Q .
BUILDING AND ENVIRONMENT, 1996, 31 (03) :233-244
[8]   COMPARISON OF DIFFERENT K-EPSILON MODELS FOR INDOOR AIR-FLOW COMPUTATIONS [J].
CHEN, Q .
NUMERICAL HEAT TRANSFER PART B-FUNDAMENTALS, 1995, 28 (03) :353-369
[9]  
CHEN Q, 2001, RP1009 ASHRAE
[10]   Theoretical and experimental investigation of wall confluent jets ventilation and comparison with wall displacement ventilation [J].
Cho, Youngjun ;
Awbi, Hazim B. ;
Karimipanah, Taghi .
BUILDING AND ENVIRONMENT, 2008, 43 (06) :1091-1100