Ultralow-Dose CT (REDUCTION Protocol) for Extremity Fracture Evaluation Is as Safe and Effective as Conventional CT: An Evaluation of Quality Outcomes

被引:23
|
作者
Konda, Sanjit R. [1 ,2 ]
Goch, Abraham M. [1 ]
Haglin, Jack [1 ]
Egol, Kenneth A. [1 ,2 ]
机构
[1] NYU, Hosp Joint Dis, Dept Orthopaed Surg, 301 East 17th St, New York, NY 10003 USA
[2] Jamaica Hosp, Dept Orthopaed Surg, Med Ctr, New York, NY USA
关键词
computed tomography; CT scan; extremity; fracture; low dose; 3-DIMENSIONAL COMPUTED-TOMOGRAPHY; RADIATION-EXPOSURE; TIBIAL PLATEAU; KNEE-JOINT; SCANS; RISK; CLASSIFICATION; RELIABILITY; STRATEGIES; MANAGEMENT;
D O I
10.1097/BOT.0000000000001137
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: To assess clinical and hospital quality outcomes of patients receiving the previously reported Reduced Effective Dose Using Computed Tomography In Orthopaedic Injury (REDUCTION) imaging protocol. Design: Retrospective Chart review. Setting: Level I Trauma Center and affiliated Tertiary Care Hospital Center. Patients/Participants: Fifty patients who received this protocol for acute traumatic fracture evaluation and met the inclusion criteria were compared with a cohort of 50 patients matched for age and fracture type who previously received conventional CT scanning for acute traumatic fracture evaluation. Intervention: Reduced Effective Dose Using Computed Tomography In Orthopaedic Injury (REDUCTION) protocol for diagnostic fracture evaluation. Main Outcome Measures: Estimated effective radiation doses were calculated and compared using Digital Imaging and Communications in Medicine (DICOM) information from all included studies. Patient outcomes between groups were compared with time to fracture union as the primary outcome. Secondary outcome measures included the presence of complication defined as infection, malunion, nonunion, failure of nonoperative treatment, painful implants, and implant failure. Other secondary quality outcomes that were recorded included readmission within 30 days and hospital length of stay. Functional quality measures included joint range of motion. Statistical analyses were conducted to identify significant differences between cohorts (significance designated as P < 0.05). Results: Patient characteristics between cohorts were not significantly different with respect to age, sex, body mass index, comorbidities, injury mechanism, or injury location. Fractures of the elbow, hip, knee, and foot/ankle were evaluated. Mean clinical follow-up was 9.5 +/- 4.9 months for the REDUCTION cohort and 12.4 +/- 5.3 months for the conventional CT cohort. Mean estimated effective dose for all REDUCTION scans was 0.15 milliSieverts (mSv) as compared to 1.50 mSv for the conventional CT cohort (P = 0.037). Preoperative diagnosis was confirmed intraoperatively in 49/50 cases in the REDUCTION cohort compared with 48/50 cases in the conventional CT cohort (P = 0.79). Outcomes including time to union, range of motion, complications, readmission, treatment failure, reoperation, and length of stay were not significantly different between groups. Conclusions: The REDUCTION protocol represents ultralow-dose CT developed for minimizing radiation exposure to patients presenting with traumatic fractures. This protocol resulted in a 10-fold reduction in radiation exposure. No difference in clinical or hospital quality outcomes was detected between patients who received this protocol as compared to those receiving automated dose CT. The REDUCTION protocol is a safe and effective method of performing CT for extremity fractures with significantly reduced radiation risk.
引用
收藏
页码:216 / 222
页数:7
相关论文
共 50 条
  • [21] Effect of tin filter-based spectral shaping CT on image quality and radiation dose for routine use on ultralow-dose CT protocols: A phantom study
    Greffier, J.
    Pereira, F.
    Hamard, A.
    Addala, T.
    Beregi, J. P.
    Frandon, J.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2020, 101 (06) : 373 - 381
  • [22] Usefulness of Ultralow-Dose (Submillisievert) Chest CT Using Iterative Reconstruction for Initial Evaluation of Sharp Fish Bone Esophageal Foreign Body
    Kim, Eun Young
    Min, Young Gi
    Bista, Anjali Basnyat
    Park, Kyung Joo
    Kang, Doo Kyoung
    Sun, Joo Sung
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 205 (05) : 985 - 990
  • [23] Evaluation of whole body Ultralow-Dose CT for the assessment of ventriculoperitoneal shunt complications: an experimental ex-vivo study in a swine model
    Othman, Ahmed
    Hamou, Hussam A.
    Pjontek, Rastislav
    Afat, Saif
    Clusmann, Hans
    Wiesmann, Martin
    Brockmann, Marc A.
    EUROPEAN RADIOLOGY, 2015, 25 (08) : 2199 - 2204
  • [24] Evaluation of Dose Reduction and Image Quality in Pediatric Multi-detector CT
    Lee, Seung-Wan
    Kim, Hee-Joung
    Kim, Dae-Hong
    Lee, Chang-Lae
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2010, 57 (01) : 183 - 191
  • [25] Evaluation of patient effective dose in a PET/CT test
    Paiva, Fernanda Guerra
    Santana, Priscila do Carmo
    Mourao, Arnaldo Prata
    APPLIED RADIATION AND ISOTOPES, 2019, 145 : 137 - 141
  • [26] Absorbed dose evaluation to patients undergoing PET-CT and conventional CT examinations
    Huang, YH
    Wu, TH
    Su, CT
    Chen, MC
    Hung, JJ
    Lee, JS
    RADIATION PHYSICS AND CHEMISTRY, 2004, 71 (3-4) : 985 - 986
  • [27] Ultralow dose CT attenuation correction for lung cancer PET/CT screening - a phantom evaluation study
    Sjoholm, Therese
    Schaefferkoetter, Josh
    Townsend, David
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [28] COMPARISON OF CONVENTIONAL AND TRIPLE BOLUS CT UROGRAPHY PROTOCOLS FOR RADIATION DOSE REDUCTION IN HEMATURIA EVALUATION
    Karani, Rajiv
    Sung, John M.
    Xie, Lillian
    Arada, Raphael
    Parkhomenko, Egor
    Lama, Daniel J.
    Jefferson, Francis
    Lee, Sonia
    Lall, Chandana
    Patel, Roshan M.
    Okhunov, Zhamshid
    Tapiero, Shlomi
    Clayman, Ralph V.
    Landman, Jaime
    JOURNAL OF UROLOGY, 2020, 203 : E528 - E528
  • [29] Evaluation of dose reduction and image quality in CT colonography: Comparison of low-dose CT with iterative reconstruction and routine-dose CT with filtered back projection
    Nagata, Koichi
    Fujiwara, Masanori
    Kanazawa, Hidenori
    Mogi, Tomohiro
    Iida, Nao
    Mitsushima, Toru
    Lefor, Alan T.
    Sugimoto, Hideharu
    EUROPEAN RADIOLOGY, 2015, 25 (01) : 221 - 229
  • [30] Evaluation of dose reduction and image quality in CT colonography: Comparison of low-dose CT with iterative reconstruction and routine-dose CT with filtered back projection
    Koichi Nagata
    Masanori Fujiwara
    Hidenori Kanazawa
    Tomohiro Mogi
    Nao Iida
    Toru Mitsushima
    Alan T. Lefor
    Hideharu Sugimoto
    European Radiology, 2015, 25 : 221 - 229