Density modification of cryo-EM maps

被引:27
|
作者
Terwilliger, Thomas C. [1 ,2 ]
Sobolev, Oleg V. [3 ]
Afonine, Pavel V. [3 ]
Adams, Paul D. [3 ,4 ]
Read, Randy J. [5 ]
机构
[1] New Mexico Consortium, Los Alamos, NM 87544 USA
[2] Los Alamos Natl Lab, Biosci Div, Mail Stop M888, Los Alamos, NM 87545 USA
[3] Lawrence Berkeley Natl Lab, Mol Biophys & Integrated Bioimaging Div, Berkeley, CA 94720 USA
[4] Univ Calif Berkeley, Dept Bioengn, Berkeley, CA 94720 USA
[5] Univ Cambridge, Cambridge Inst Med Res, Dept Haematol, Keith Peters Bldg,Hills Rd, Cambridge CB2 0XY, England
基金
美国国家卫生研究院; 英国惠康基金;
关键词
electron cryomicroscopy; structural biology; map improvement; density modification; RESOLUTION; SPACE; REAL;
D O I
10.1107/S205979832001061X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Density modification uses expectations about features of a map such as a flat solvent and expected distributions of density in the region of the macromolecule to improve individual Fourier terms representing the map. This process transfers information from one part of a map to another and can improve the accuracy of a map. Here, the assumptions behind density modification for maps from electron cryomicroscopy are examined and a procedure is presented that allows the incorporation of model-based information. Density modification works best in cases where unfiltered, unmasked maps with clear boundaries between the macromolecule and solvent are visible, and where there is substantial noise in the map, both in the region of the macromolecule and the solvent. It also is most effective if the characteristics of the map are relatively constant within regions of the macromolecule and the solvent. Model-based information can be used to improve density modification, but model bias can in principle occur. Here, model bias is reduced by using ensemble models that allow an estimation of model uncertainty. A test of model bias is presented that suggests that even if the expected density in a region of a map is specified incorrectly by using an incorrect model, the incorrect expectations do not strongly affect the final map.
引用
收藏
页码:912 / 925
页数:14
相关论文
共 50 条
  • [31] Quality vs. Resolution in Cryo-EM Maps
    Stagg, Scott M.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2019, 75 : A412 - A412
  • [32] Refinement of Atomic Structures Against cryo-EM Maps
    Murshudov, G. N.
    RESOLUTION REVOLUTION: RECENT ADVANCES IN CRYOEM, 2016, 579 : 277 - 305
  • [33] A Graph Based Method for the Prediction of Backbone Trace from Cryo-EM Density Maps
    Collins, Peter
    Si, Dong
    ACM-BCB' 2017: PROCEEDINGS OF THE 8TH ACM INTERNATIONAL CONFERENCE ON BIOINFORMATICS, COMPUTATIONAL BIOLOGY,AND HEALTH INFORMATICS, 2017, : 691 - 697
  • [34] Flexible Fitting of Atomic Models into Cryo-EM Density Maps Guided by Helix Correspondences
    Dou, Hang
    Burrows, Derek W.
    Baker, Matthew L.
    Jul, Tao
    BIOPHYSICAL JOURNAL, 2017, 112 (12) : 2479 - 2493
  • [35] Interpretation of RNA cryo-EM maps of various resolutions
    Kretsch, Rachael
    Das, Rhiju
    Chiu, Wah
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2021, 77 : A217 - A217
  • [36] GemSpot allows modeling of ligands in cryo-EM maps
    Singh, Arunima
    NATURE METHODS, 2020, 17 (07) : 656 - 656
  • [37] Bayesian Modeling of Biomolecular Assemblies with Cryo-EM Maps
    Habeck, Michael
    FRONTIERS IN MOLECULAR BIOSCIENCES, 2017, 4
  • [38] Fast and sensitive rigid-body fitting into cryo-EM density maps with PowerFit
    van Zundert, Gydo C. P.
    Bonvin, Alexandre M. J. J.
    AIMS BIOPHYSICS, 2015, 2 (02): : 73 - 87
  • [39] Improving the visualization of cryo-EM density reconstructions
    Spiegel, M.
    Duraisamy, A. K.
    Schroeder, G. F.
    JOURNAL OF STRUCTURAL BIOLOGY, 2015, 191 (02) : 207 - 213
  • [40] Using Combined Features to Analyze Atomic Structures Derived from Cryo-EM Density Maps
    Chen, Lin
    He, Jing
    ACM-BCB'18: PROCEEDINGS OF THE 2018 ACM INTERNATIONAL CONFERENCE ON BIOINFORMATICS, COMPUTATIONAL BIOLOGY, AND HEALTH INFORMATICS, 2018, : 651 - 655