Density modification of cryo-EM maps

被引:27
|
作者
Terwilliger, Thomas C. [1 ,2 ]
Sobolev, Oleg V. [3 ]
Afonine, Pavel V. [3 ]
Adams, Paul D. [3 ,4 ]
Read, Randy J. [5 ]
机构
[1] New Mexico Consortium, Los Alamos, NM 87544 USA
[2] Los Alamos Natl Lab, Biosci Div, Mail Stop M888, Los Alamos, NM 87545 USA
[3] Lawrence Berkeley Natl Lab, Mol Biophys & Integrated Bioimaging Div, Berkeley, CA 94720 USA
[4] Univ Calif Berkeley, Dept Bioengn, Berkeley, CA 94720 USA
[5] Univ Cambridge, Cambridge Inst Med Res, Dept Haematol, Keith Peters Bldg,Hills Rd, Cambridge CB2 0XY, England
基金
美国国家卫生研究院; 英国惠康基金;
关键词
electron cryomicroscopy; structural biology; map improvement; density modification; RESOLUTION; SPACE; REAL;
D O I
10.1107/S205979832001061X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Density modification uses expectations about features of a map such as a flat solvent and expected distributions of density in the region of the macromolecule to improve individual Fourier terms representing the map. This process transfers information from one part of a map to another and can improve the accuracy of a map. Here, the assumptions behind density modification for maps from electron cryomicroscopy are examined and a procedure is presented that allows the incorporation of model-based information. Density modification works best in cases where unfiltered, unmasked maps with clear boundaries between the macromolecule and solvent are visible, and where there is substantial noise in the map, both in the region of the macromolecule and the solvent. It also is most effective if the characteristics of the map are relatively constant within regions of the macromolecule and the solvent. Model-based information can be used to improve density modification, but model bias can in principle occur. Here, model bias is reduced by using ensemble models that allow an estimation of model uncertainty. A test of model bias is presented that suggests that even if the expected density in a region of a map is specified incorrectly by using an incorrect model, the incorrect expectations do not strongly affect the final map.
引用
收藏
页码:912 / 925
页数:14
相关论文
共 50 条
  • [1] Improvement of cryo-EM maps by density modification
    Terwilliger, Thomas C.
    Ludtke, Steven J.
    Read, Randy J.
    Adams, Paul D.
    Afonine, Pavel, V
    NATURE METHODS, 2020, 17 (09) : 923 - +
  • [2] Improvement of cryo-EM maps by density modification
    Thomas C. Terwilliger
    Steven J. Ludtke
    Randy J. Read
    Paul D. Adams
    Pavel V. Afonine
    Nature Methods, 2020, 17 : 923 - 927
  • [3] ANALYSES OF SUBNANOMETER RESOLUTION CRYO-EM DENSITY MAPS
    Baker, Matthew L.
    Baker, Mariah R.
    Hryc, Corey F.
    DiMaio, Frank
    METHODS IN ENZYMOLOGY, VOL 483: CRYO-EM, PART C: ANALYSES, INTERPRETATION, AND CASE STUDIES, 2010, 483 : 1 - 29
  • [4] Quantifying the local resolution of cryo-EM density maps
    Kucukelbir A.
    Sigworth F.J.
    Tagare H.D.
    Nature Methods, 2014, 11 (1) : 63 - 65
  • [5] Automated Threshold Selection for Cryo-EM Density Maps
    Pfab, Jonas
    Si, Dong
    ACM-BCB'19: PROCEEDINGS OF THE 10TH ACM INTERNATIONAL CONFERENCE ON BIOINFORMATICS, COMPUTATIONAL BIOLOGY AND HEALTH INFORMATICS, 2019, : 161 - 166
  • [6] De novo detection of symmetry in cryo-EM density maps
    Tykac, M.
    Cerny, J.
    Murshudov, G. N.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2021, 77 : C692 - C692
  • [7] Cryo-EM density maps adjustment for subtraction, consensus and sharpening
    Gimenez, E. Fernandez
    Martinez, M.
    Sanchez-Garcia, R.
    Marabini, R.
    Ramirez-Aportela, E.
    Conesa, P.
    Carazo, J. M.
    Sorzano, C. O. S.
    JOURNAL OF STRUCTURAL BIOLOGY, 2021, 213 (04)
  • [8] De Novo modeling in cryo-EM density maps with Pathwalking
    Chen, Muyuan
    Baldwin, Philip R.
    Ludtke, Steven J.
    Baker, Matthew L.
    JOURNAL OF STRUCTURAL BIOLOGY, 2016, 196 (03) : 289 - 298
  • [9] A New Algorithm for Improving the Resolution of Cryo-EM Density Maps
    Hirsch, Michael
    Schoelkopf, Bernhard
    Habeck, Michael
    RESEARCH IN COMPUTATIONAL MOLECULAR BIOLOGY, PROCEEDINGS, 2010, 6044 : 174 - 188
  • [10] Modelling structures in cryo-EM maps
    Malhotra, Sony
    Trager, Sylvain
    Dal Peraro, Matteo
    Topf, Maya
    CURRENT OPINION IN STRUCTURAL BIOLOGY, 2019, 58 : 105 - 114