The reliability of surface electromyography to assess quadriceps fatigue during multi joint tasks in healthy and painful knees

被引:19
作者
Callaghan, Michael J. [1 ]
McCarthy, Christopher J. [1 ]
Oldham, Jacqueline A. [1 ]
机构
[1] Manchester Royal Infirm, Ctr Rehabil Sci, Manchester M13 9WL, Lancs, England
关键词
Muscle fatigue; Isometric contraction; EMG; Reliability; Quadriceps; Osteoarthritis; Anterior knee pain; Multi joint; MUSCLE FATIGUE; ISOMETRIC CONTRACTIONS; PARASPINAL MUSCLES; MEDIAN FREQUENCY; EMG VARIABLES; KINETIC-CHAIN; BACK-PAIN; REPEATABILITY; REHABILITATION; EXERCISE;
D O I
10.1016/j.jelekin.2007.05.004
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
This study's aim was to determine the between days reliability of surface EMG recordings from the superficial quadriceps during a multi joint sub-maximal fatiguing protocol. Three subject groups (healthy n = 29; patellofemoral pain syndrome n = 74; knee osteoarthritis n = 55) performed the task at 60 maximum voluntary isometric contraction on three separate days. Spectral and amplitude EMG parameters were recorded from vastus medialis oblique, vastus lateralis and rectus femoris and were analysed for between days reliability using intraclass correlation coefficient (ICC((2.1))), the standard errors of measure and smallest detectable differences. For frequency results, initial and final frequency values had 'good' or 'excellent' reliability in all groups for all muscles. ICCs for median frequency slopes for vastus medialis oblique, vastus lateralis, and rectus femoris respectively, in the osteoarthritis group were 0.04, 0.55, and 0.72; in the patellofemoral pain group were 0.41, 0.17, and 0.33; in the healthy group were 0.68, 0.64, and 0.31. The standard errors of measurement and smallest detectable differences for all groups and for all muscles were unacceptably high. For amplitude results, ICC root mean squared initial and final values were 'good' to 'excellent' for all groups and all muscles, albeit with high measurement error. The ICCs for root mean squared slopes in all tests were 'poor' with extremely high measurement error. The poor between days reliability and high measurement error suggests that surface EMG should not be adopted to assess fatigue during multi joint sub-maximal isometric quadriceps testing. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:172 / 180
页数:9
相关论文
共 38 条
[1]  
Altman DG, 1991, PRACTICAL STAT MED R, Vxii
[2]  
ARENDTNEILSEN L, 1998, EUR J APPL PHYSL, V58, P20
[3]   Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine [J].
Atkinson, G ;
Nevill, AM .
SPORTS MEDICINE, 1998, 26 (04) :217-238
[4]  
Basmajian JV., 1987, MUSCLES ALIVE THEIR, V5th
[5]  
CALLAGHAN MJ, 2001, MAN THER, V6, P15
[6]   Physical therapy for patellofemoral pain - A randomized, double-blinded, placebo-controlled trial [J].
Crossley, K ;
Bennell, K ;
Green, S ;
Cowan, S ;
McConnell, J .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2002, 30 (06) :857-865
[7]   The reliability of monopolar and bipolar fine-wire electromyographic measurement of muscle fatigue [J].
Davis, BA ;
Krivickas, LS ;
Maniar, R ;
Newandee, DA ;
Feinberg, JH .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1998, 30 (08) :1328-1335
[8]   USE OF THE SURFACE EMG SIGNAL FOR PERFORMANCE EVALUATION OF BACK MUSCLES [J].
DE LUCA, CJ .
MUSCLE & NERVE, 1993, 16 (02) :210-216
[9]  
DELUCA CJ, 1985, CRC CRIT R BIOMED EN, V11, P251
[10]   Interpretation of EMG changes with fatigue: facts, pitfalls, and fallacies [J].
Dimitrova, NA ;
Dimitrov, GV .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2003, 13 (01) :13-36