Estimation of Tegaserod Maleate by Differential Pulse Polarography

被引:0
|
作者
Rajput, S. J. [1 ]
Raj, H. A. [1 ]
机构
[1] Maharaja Sayajirao Univ Baroda, Fac Engn & Technol, Dept Pharm, Qual Assurance Lab, Vadodara 390001, India
关键词
Differential pulse polarography; hanging mercury drop electrode; DRUG;
D O I
10.4103/0250-474X.51956
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
A highly sensitive differential pulse polarographic method has been developed for the estimation of tegaserod maleate after treating it with hydrogen peroxide solution. The oxidation of tegaserod maleate is a reversible process as the oxidized product could be reduced at hanging mercury drop electrode in a quantitative manner using differential pulse polarography mode. The limit of quantification was 0.1ng/ml. The voltametric peak was obtained at -1.05 volts in presence of 0.1M potassium chloride as supporting electrolyte. The technique could be used successfully to analyze tegaserod maleate in its tablet formulation.
引用
收藏
页码:50 / 52
页数:3
相关论文
共 50 条
  • [41] THE DETERMINATION OF FURAZOLIDONE IN TABLETS BY DIFFERENTIAL PULSE POLAROGRAPHY
    TUNCEL, M
    ALTIOKKA, G
    PHARMAZIE, 1992, 47 (04): : 304 - 304
  • [42] Determination of organophosphorous pesticides by differential pulse polarography
    Madhavi, G
    Damodar, J
    Mohan, SK
    Reddy, SJ
    BULLETIN OF ELECTROCHEMISTRY, 1999, 15 (12): : 535 - 538
  • [43] Determination of methylamphetamine in urine by differential pulse polarography
    Fushinuki, Y
    Taniguchi, I
    ANALYTICAL SCIENCES, 1998, 14 (02) : 265 - 268
  • [44] AMPEROMETRIC TITRATIONS EMPLOYING DIFFERENTIAL PULSE POLAROGRAPHY
    MYERS, DJ
    OSTERYOUNG, J
    ANALYTICAL CHEMISTRY, 1974, 46 (03) : 356 - 359
  • [45] DETERMINATION OF ACRYLAMIDE MONOMER BY DIFFERENTIAL PULSE POLAROGRAPHY
    BETSO, SR
    MCLEAN, JD
    ANALYTICAL CHEMISTRY, 1976, 48 (04) : 766 - 770
  • [46] OPTIMALIZATION OF THE MEASURING TECHNIQUE IN DIFFERENTIAL PULSE POLAROGRAPHY
    SAUR, D
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1979, 298 (01): : 47 - 48
  • [47] TRACE DETERMINATION OF ZINC BY DIFFERENTIAL PULSE POLAROGRAPHY
    LAKHANI, R
    JOSHI, AP
    JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 1987, 64 (06) : 380 - 381
  • [48] Determination of Nifuroxazide in Capsules by Differential Pulse Polarography
    A. Radi
    S. El-Laban
    I. M. M. Kenawy
    Analytical Sciences, 1998, 14 : 607 - 608
  • [49] ANALYSIS OF PLATING BATHS BY DIFFERENTIAL PULSE POLAROGRAPHY
    REISS, JJ
    ASHLEY, L
    BOHRA, SK
    PLATING AND SURFACE FINISHING, 1983, 70 (05): : 22 - 22
  • [50] ASSAY OF FLURAZEPAM IN PLASMA BY DIFFERENTIAL PULSE POLAROGRAPHY
    CLIFFORD, JM
    SMYTH, MR
    SMYTH, WF
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1974, 272 (03): : 198 - 201