Ultrasound-guided needle insertion robotic system for percutaneous puncture

被引:44
作者
Chen, Shihang [1 ]
Wang, Fang [2 ]
Lin, Yanping [1 ]
Shi, Qiusheng [2 ]
Wang, Yanli [3 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Mech Engn, Shanghai, Peoples R China
[2] Shanghai Jiao Tong Univ, Sch Med, Shanghai Gen Hosp, Shanghai, Peoples R China
[3] Fudan Univ, Shanghai Canc Ctr, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
Minimally invasive surgery; Needle insertion; Percutaneous puncture; Surgical robot assistance; Ultrasound guide;
D O I
10.1007/s11548-020-02300-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose Ultrasound (US)-guided percutaneous puncture technology can realize real-time, minimally invasive interventional therapy without radiation. The location accuracy of the puncture needle directly determines the precision and safety of the operation. It is a challenge for novices and young surgeons to perform a free-hand puncture guided by the ultrasound images to achieve the desired accuracy. This work aims to develop a robotic system to assist surgeons to perform percutaneous punctures with high precision. Methods An US-guided puncture robot was designed to allow the mounting and control of the needle to achieve localization and insertion. The US probe fitted within the puncture robot was held by a passive arm. Moreover, the puncture robot was calibrated with a novel calibration method to achieve coordinate transformation between the robot and the US image. The system allowed the operators to plan the puncture target and puncture path on US images, and the robot performed needle insertion automatically. Five groups of puncture experiments were performed to verify the validity and accuracy of the proposed robotic system. Results Assisted by the robotic system, the positioning and orientation accuracies of the needle insertion were 0.9 +/- 0.29 mm and 0.76 +/- 0.34 degrees, respectively. These are improved compared with the results obtained with the free-hand puncture (1.82 +/- 0.51 mm and 2.79 +/- 1.32 degrees, respectively). Moreover, the proposed robotic system can reduce the operation time and number of needle insertions (14.28 +/- 3.21 s and one needle insertion, respectively), compared with the free-hand puncture (25.14 +/- 6.09 s and 1.96 +/- 0.68 needle insertions, respectively). Conclusion A robotic system for percutaneous puncture guided by US images was developed and demonstrated. The experimental results indicate that the proposed system is accurate and feasible. It can assist novices and young surgeons to perform the puncture operation with increased accuracy.
引用
收藏
页码:475 / 484
页数:10
相关论文
共 27 条
  • [1] Ultrasound-guided three-dimensional needle steering in biological tissue with curved surfaces
    Abayazid, Momen
    Moreira, Pedro
    Shahriari, Navid
    Patil, Sachin
    Alterovitz, Ron
    Misra, Sarthak
    [J]. MEDICAL ENGINEERING & PHYSICS, 2015, 37 (01) : 145 - 150
  • [2] Experimental evaluation of ultrasound-guided 3D needle steering in biological tissue
    Abayazid, Momen
    Vrooijink, Gustaaf J.
    Patil, Sachin
    Alterovitz, Ron
    Misra, Sarthak
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2014, 9 (06) : 931 - 939
  • [3] The evolution of robotic surgery: surgical and anaesthetic aspects
    Ashrafian, H.
    Clancy, O.
    Grover, V.
    Darzi, A.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2017, 119 : I72 - I84
  • [4] Adaptive Kinematic Control of a Robotic Venipuncture Device Based on Stereo Vision, Ultrasound, and Force Guidance
    Balter, Max L.
    Chen, Alvin I.
    Maguire, Timothy J.
    Yarmush, Martin L.
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2017, 64 (02) : 1626 - 1635
  • [5] Three-dimensional ultrasound-guided robotic needle placement: an experimental evacuation
    Boctor, Emad M.
    Choti, Michael A.
    Burdette, Everette C.
    Webster, Robert J., III
    [J]. INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2008, 4 (02) : 180 - 191
  • [6] Flexible Needle Steering in Moving Biological Tissue With Motion Compensation Using Ultrasound and Force Feedback
    Chevrie, Jason
    Shahriari, Navid
    Babel, Marie
    Krupa, Alexandre
    Misra, Sarthak
    [J]. IEEE ROBOTICS AND AUTOMATION LETTERS, 2018, 3 (03): : 2338 - 2345
  • [7] Surgical Robot for Single-Incision Laparoscopic Surgery
    Choi, Hyundo
    Kwak, Ho-Seong
    Lim, Yo-An
    Kim, Hyung-Joo
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2014, 61 (09) : 2458 - 2466
  • [8] Robotic ultrasound-guided facet joint insertion
    Esteban, Javier
    Simson, Walter
    Witzig, Sebastian Requena
    Rienmueller, Anna
    Virga, Salvatore
    Frisch, Benjamin
    Zettinig, Oliver
    Sakara, Drazen
    Ryang, Yu-Mi
    Navab, Nassir
    Hennersperger, Christoph
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2018, 13 (06) : 895 - 904
  • [9] First Robotic Ultrasound-Guided Nerve Blocks in Humans Using the Magellan System
    Hemmerling, Thomas M.
    Taddei, Riccardo
    Wehbe, Mohamad
    Cyr, Shantale
    Zaouter, Cedrick
    Morse, Joshua
    [J]. ANESTHESIA AND ANALGESIA, 2013, 116 (02) : 491 - 494
  • [10] An ultrasound-directed robotic system for microwave ablation of liver cancer
    Huang, Qiang
    Bian, Gui-bin
    Duan, Xing-guang
    Zhao, Hong-hua
    Liang, Ping
    [J]. ROBOTICA, 2010, 28 : 209 - 214