Image analysis for denoising full-field frequency-domain fluorescence lifetime images

被引:28
|
作者
Spring, B. Q. [1 ]
Clegg, R. M. [1 ,2 ]
机构
[1] Univ Illinois, Ctr Biophys & Computat Biol, Urbana, IL 61801 USA
[2] Univ Illinois, Dept Phys, Urbana, IL 61801 USA
关键词
Denoising; FLIM; fluorescence lifetime imaging; image analysis; microscopy; polar plot; TI-Haar; wavelet; GLOBAL ANALYSIS; FLIM; REPRESENTATION; SPECTROSCOPY; MICROSCOPE; RESOLUTION; NOISE;
D O I
10.1111/j.1365-2818.2009.03212.x
中图分类号
TH742 [显微镜];
学科分类号
摘要
Video-rate fluorescence lifetime-resolved imaging microscopy (FLIM) is a quantitative imaging technique for measuring dynamic processes in biological specimens. FLIM offers valuable information in addition to simple fluorescence intensity imaging; for instance, the fluorescence lifetime is sensitive to the microenvironment of the fluorophore allowing reliable differentiation between concentration differences and dynamic quenching. Homodyne FLIM is a full-field frequency-domain technique for imaging fluorescence lifetimes at every pixel of a fluorescence image simultaneously. If a single modulation frequency is used, video-rate image acquisition is possible. Homodyne FLIM uses a gain-modulated image intensified charge-coupled device (ICCD) detector, which unfortunately is a major contribution to the noise of the measurement. Here we introduce image analysis for denoising homodyne FLIM data. The denoising routine is fast, improves the extraction of the fluorescence lifetime value(s) and increases the sensitivity and fluorescence lifetime resolving power of the FLIM instrument. The spatial resolution (especially the high spatial frequencies not related to noise) of the FLIM image is preserved, because the denoising routine does not blur or smooth the image. By eliminating the random noise known to be specific to photon noise and from the intensifier amplification, the fidelity of the spatial resolution is improved. The polar plot projection, a rapid FLIM analysis method, is used to demonstrate the effectiveness of the denoising routine with exemplary data from both physical and complex biological samples. We also suggest broader impacts of the image analysis for other fluorescence microscopy techniques (e. g. super-resolution imaging).
引用
收藏
页码:221 / 237
页数:17
相关论文
共 50 条
  • [1] Rapid Frequency-Domain FLIM Spinning Disk Confocal Microscope: Lifetime Resolution, Image Improvement and Wavelet Analysis
    Chittanon Buranachai
    Daichi Kamiyama
    Akira Chiba
    Benjamin D. Williams
    Robert M. Clegg
    Journal of Fluorescence, 2008, 18 : 929 - 942
  • [2] Rapid frequency-domain FLIM spinning disk confocal microscope: Lifetime resolution, image improvement and wavelet analysis
    Buranachai, Chittanon
    Kamiyama, Daichi
    Chiba, Akira
    Williams, Benjamin D.
    Clegg, Robert M.
    JOURNAL OF FLUORESCENCE, 2008, 18 (05) : 929 - 942
  • [3] Frequency-Domain Deep Guided Image Denoising
    Sheng, Zehua
    Liu, Xiongwei
    Cao, Si-Yuan
    Shen, Hui-Liang
    Zhang, Huaqi
    IEEE TRANSACTIONS ON MULTIMEDIA, 2023, 25 : 6767 - 6781
  • [4] Linear Behavior of the Phase Lifetime in Frequency-Domain Fluorescence Lifetime Imaging of FRET Constructs
    Sumetsky, Daniel
    Jiang, James Y.
    Ayad, Marina A.
    Mahon, Timothy
    Menaesse, Audrey
    Cararo-Lopes, Marina M.
    Patel, Mihir V.
    Firestein, Bonnie L.
    Boustany, Nada N.
    FRONTIERS IN PHYSICS, 2021, 9 (09):
  • [5] LIFETIME MAP RECONSTRUCTION IN FREQUENCY-DOMAIN FLUORESCENCE LIFETIME IMAGING MICROSCOPY
    Roudot, Philippe
    Kervrann, Charles
    Waharte, Francois
    Boulanger, Jerome
    2012 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP 2012), 2012, : 2537 - 2540
  • [6] LIFETIME ESTIMATION OF MOVING VESICLES IN FREQUENCY-DOMAIN FLUORESCENCE LIFETIME IMAGING MICROSCOPY
    Roudot, Philippe
    Kervrann, Charles
    Waharte, Francois
    2012 9TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2012, : 668 - 671
  • [7] Lifetime estimation of moving subcellular objects in frequency-domain fluorescence lifetime imaging microscopy
    Roudot, Philippe
    Kervrann, Charles
    Blouin, Cedric M.
    Waharte, Francois
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2015, 32 (10) : 1821 - 1835
  • [8] Frequency-domain fluorescence lifetime imaging system (pco.flim) based on an in-pixel dual tap control CMOS image sensor
    Franke, Robert
    Holst, Gerhard A.
    IMAGING, MANIPULATION, AND ANALYSIS OF BIOMOLECULES, CELLS, AND TISSUES XIII, 2015, 9328
  • [9] Polar Plot Representation for Frequency-Domain Analysis of Fluorescence Lifetimes
    Glen I. Redford
    Robert M. Clegg
    Journal of Fluorescence, 2005, 15 : 805 - 815
  • [10] Polar plot representation for frequency-domain analysis of fluorescence lifetimes
    Redford, GI
    Clegg, RM
    JOURNAL OF FLUORESCENCE, 2005, 15 (05) : 805 - 815