Robust megavoltage x-ray spectra estimation from transmission measurements

被引:8
|
作者
Manciu, Marian [1 ]
Manciu, Felicia S. [1 ]
Vulcan, Teodor [1 ]
Nes, Elena [2 ]
Waggener, Robert G. [2 ]
机构
[1] Univ Texas El Paso, Dept Phys, El Paso, TX 79968 USA
[2] Univ Texas Hlth Sci Ctr San Antonio, Dept Radiol, Div Radiat Oncol, San Antonio, TX 78229 USA
关键词
Photon spectra; megavoltage photon beams; spectral reconstruction; bremsstrahlung; attenuation curves; inverse problem; linear accelerators; PHOTON SPECTRA; RECONSTRUCTION;
D O I
10.3233/XST-2009-0214
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Megavoltage X-ray sources are commonly used for therapy planning, and knowledge of their spectral distribution is important for accurate dose calculations. There are many methods that could provide reasonable estimations of Megavoltage X-ray spectra, when very accurate attenuation data or at least very good set of initial guesses of the spectra are available. We present here a novel method, which can be used for accurate Megavoltage spectral reconstruction without any prior knowledge of spectral distribution; the method performs well even when the available transmission data are affected by noise. The method is based on a search for a smooth function that minimizes the differences between measured and calculated attenuation data. The algorithm is compared with well-known existing algorithms, using computer simulated data, both error-free and containing added random Gaussian noise. The reconstructed spectra are subsequently used to calculate the transmission through 50 cm of bone, muscle or fat tissue. It is shown that the relative errors in dose calculations, using the spectra reconstructed via this method, are significantly smaller than those obtained via well-established reconstruction algorithms - Truncated Singular Value Decomposition (TSVD) and Expectation Maximization (EM). These results suggest that the novel algorithm might be practical for routine Megavoltage therapy X-ray source calibration.
引用
收藏
页码:85 / 99
页数:15
相关论文
共 50 条
  • [1] X-ray spectra estimation using attenuation measurements from 25 kVp to 18 MV
    Waggener, RG
    Blough, MM
    Terry, JA
    Chen, D
    Lee, NE
    Zhang, S
    McDavid, WD
    MEDICAL PHYSICS, 1999, 26 (07) : 1269 - 1278
  • [2] Experimental X-ray tube spectra
    Gorgl, R
    Wobrauschek, P
    Streli, C
    Aiginger, H
    Benedikt, M
    JOURNAL OF TRACE AND MICROPROBE TECHNIQUES, 1996, 14 (03): : 589 - 604
  • [3] Application of an expectation maximization method to the reconstruction of X-ray-tube spectra from transmission data
    Endrizzi, M.
    Delogu, P.
    Oliva, P.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2014, 102 : 42 - 47
  • [4] X-ray PoseNet: 6 DoF Pose Estimation for Mobile X-ray Devices
    Bui, Mai
    Albarqouni, Shadi
    Schrapp, Michael
    Navab, Nassir
    Ilic, Slobodan
    2017 IEEE WINTER CONFERENCE ON APPLICATIONS OF COMPUTER VISION (WACV 2017), 2017, : 1036 - 1044
  • [5] Comparison of soft X-ray spectro-ptychography and scanning transmission X-ray microscopy
    Hitchcock, Adam P.
    Zhang, Chunyang
    Eraky, Haytham
    Higgins, Drew
    Belkhou, Rachid
    Millle, Nicolas
    Swaraj, Sufal
    Stanescu, Stefan
    Sun, Tianxiao
    Wang, Jian
    JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 2024, 276
  • [6] Influence of the Radiation Field Size and the Depth in Irradiated Medium on Energy Spectra of the 6 MV X-Ray Beams from Medical Linac
    Konefal, Adam
    Orlef, Andrzej
    Maniakowski, Zbigniew
    SOME ASPECTS OF MEDICAL PHYSICS - IN VIVO AND IN VITRO STUDIES, 2010, 1 : 115 - 118
  • [7] Robust X-Ray Phase Ptycho-Tomography
    Venkatakrishnan, Singanallur V.
    Farmand, Maryam
    Yu, Young-Sang
    Majidi, Hasti
    van Benthem, Klaus
    Marchesini, Stefano
    Shapiro, David A.
    Hexemer, Alexander
    IEEE SIGNAL PROCESSING LETTERS, 2016, 23 (07) : 944 - 948
  • [8] Measurements and modeling of x-ray and ECE spectra during LHCD experiments on Alcator C-Mod
    Schmidt, A. E.
    Bonoli, P. T.
    Hubbard, A. E.
    Liptac, J.
    Parker, R. R.
    Wallace, G. M.
    Wilson, J. R.
    Harvey, R. W.
    Smirnov, A. P.
    RADIO FREQUENCY POWER IN PLASMAS, 2007, 933 : 281 - +
  • [9] X-ray spectrum estimation from the transmission method using the radioluminescence of an Al2O3:C crystal
    Chen, Rui
    Zhang, Qingxian
    Zhang, Jian
    Ge, Liangquan
    Gu, Yi
    Yang, Rui
    Li, Hui
    Liu, Qiushi
    Cheng, Zhiqiang
    Lin, Yi
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2025, 57 (01)
  • [10] Spectral reconstruction of the flash X-ray generated by Dragon-I LIA based on transmission measurements
    曹靖
    肖睿
    陈楠
    曹宏睿
    阴泽杰
    NuclearScienceandTechniques, 2015, 26 (04) : 63 - 66