Estimating the number of pure chemical components in a mixture by X-ray absorption spectroscopy

被引:46
作者
Manceau, Alain [1 ,2 ]
Marcus, Matthew [3 ]
Lenoir, Thomas [4 ]
机构
[1] Univ Grenoble Alpes, ISTerre, F-38000 Grenoble, France
[2] CNRS, F-38000 Grenoble, France
[3] Univ Calif Berkeley, Adv Light Source, Berkeley, CA 94720 USA
[4] IFSTTAR, F-44344 Bouguenais, France
关键词
XANES; EXAFS; PCA; factor analysis; F-test; MULTIVARIATE CURVE RESOLUTION; CRYSTAL-STRUCTURE REFINEMENT; EXAFS SPECTROSCOPY; ZN SPECIATION; QUANTITATIVE SPECIATION; CONTAMINATED SOIL; COMPLEX-FORMATION; HEAVY-METALS; COPPER; XANES;
D O I
10.1107/S1600577514013526
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Principal component analysis (PCA) is a multivariate data analysis approach commonly used in X-ray absorption spectroscopy to estimate the number of pure compounds in multicomponent mixtures. This approach seeks to describe a large number of multicomponent spectra as weighted sums of a smaller number of component spectra. These component spectra are in turn considered to be linear combinations of the spectra from the actual species present in the system from which the experimental spectra were taken. The dimension of the experimental dataset is given by the number of meaningful abstract components, as estimated by the cascade or variance of the eigenvalues (EVs), the factor indicator function (IND), or the F-test on reduced EVs. It is shown on synthetic and real spectral mixtures that the performance of the IND and F-test critically depends on the amount of noise in the data, and may result in considerable underestimation or overestimation of the number of components even for a signal-to-noise (s/n) ratio of the order of 80 (sigma = 20) in a XANES dataset. For a given s/n ratio, the accuracy of the component recovery from a random mixture depends on the size of the dataset and number of components, which is not known in advance, and deteriorates for larger datasets because the analysis picks up more noise components. The scree plot of the EVs for the components yields one or two values close to the significant number of components, but the result can be ambiguous and its uncertainty is unknown. A new estimator, NSS-stat, which includes the experimental error to XANES data analysis, is introduced and tested. It is shown that NSS-stat produces superior results compared with the three traditional forms of PCA-based component-number estimation. A graphical user-friendly interface for the calculation of EVs, IND, F-test and NSS-stat from a XANES dataset has been developed under LabVIEW for Windows and is supplied in the supporting information. Its possible application to EXAFS data is discussed, and several XANES and EXAFS datasets are also included for download.
引用
收藏
页码:1140 / 1147
页数:8
相关论文
共 61 条
[1]   Metal distribution and contamination of the Mamut River, Malaysia, caused by copper mine discharge [J].
Ali, MF ;
Heng, LY ;
Ratnam, W ;
Nais, J ;
Ripin, R .
BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 2004, 73 (03) :535-542
[2]   XANES-PCA analysis of Ti-species in MCM-41 mesoporous silica synthesized by different method [J].
Anunziata, Oscar A. ;
Beltramone, Andrea R. ;
Martinez, Maria L. ;
Giovanetti, Lisandro J. ;
Requejo, Felix. G. ;
Lede, Eduardo .
APPLIED CATALYSIS A-GENERAL, 2011, 397 (1-2) :22-26
[3]  
Beauchemin S, 2002, SOIL SCI SOC AM J, V66, P83, DOI 10.2136/sssaj2002.0083
[4]  
Brereton R.G., 2003, Chemometrics: Data Analysis for the Laboratory and Chemical Plant
[5]   Reduction of Se(IV) in Boom Clay: XAS Solid Phase Speciation [J].
Breynaert, Eric ;
Scheinost, Andreas C. ;
Dom, Dirk ;
Rossberg, Andre ;
Vancluysen, Jacqueline ;
Gobechiya, Elena ;
Kirschhock, Christine E. A. ;
Maes, Andre .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2010, 44 (17) :6649-6655
[6]   BeerOz, a set of Matlab routines for the quantitative interpretation of spectrophotometric measurements of metal speciation in solution [J].
Brugger, Joel .
COMPUTERS & GEOSCIENCES, 2007, 33 (02) :248-261
[7]   SCREE TEST FOR NUMBER OF FACTORS [J].
CATTELL, RB .
MULTIVARIATE BEHAVIORAL RESEARCH, 1966, 1 (02) :245-276
[8]   X-ray absorption spectroscopic investigation of partially reduced cobalt species in Co-MCM-41 catalysts during synthesis of single-wall carbon nanotubes [J].
Ciuparu, D ;
Haider, P ;
Fernández-García, M ;
Chen, Y ;
Lim, S ;
Haller, GL ;
Pfefferle, L .
JOURNAL OF PHYSICAL CHEMISTRY B, 2005, 109 (34) :16332-16339
[9]   Multivariate Curve Resolution Analysis for Interpretation of Dynamic Cu K-Edge X-ray Absorption Spectroscopy Spectra for a Cu Doped V2O5 Lithium Battery [J].
Conti, Paolo ;
Zamponi, Silvia ;
Giorgetti, Marco ;
Berrettoni, Mario ;
Smyrl, William H. .
ANALYTICAL CHEMISTRY, 2010, 82 (09) :3629-3635
[10]   Multivariate curve resolution (MCR) from 2000: Progress in concepts and applications [J].
de Juan, Anna ;
Tauler, Roma .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2006, 36 (3-4) :163-176