X-ray Magnetic Resonance Fusion Modality May Reduce Radiation Exposure and Contrast Dose in Diagnostic Cardiac Catheterization of Congenital Heart Disease

被引:23
作者
Abu Hazeem, Anas A. [1 ]
Dori, Yoav [1 ,2 ]
Whitehead, Kevin K. [1 ,2 ]
Harris, Matthew A. [1 ,2 ]
Fogel, Mark A. [1 ,2 ]
Gillespie, Matthew J. [1 ,2 ]
Rome, Jonathan J. [1 ,2 ]
Glatz, Andrew C. [1 ,2 ,3 ]
机构
[1] Childrens Hosp Philadelphia, Div Cardiol, Philadelphia, PA 19104 USA
[2] Univ Penn, Dept Pediat, Perelman Sch Med, Philadelphia, PA 19104 USA
[3] Univ Penn, Perelman Sch Med, Ctr Clin Epidemiol & Biostat, Philadelphia, PA 19104 USA
关键词
pediatric interventions; cardiac MRI; RISK; VALIDATION; CHILDHOOD; SURGERY;
D O I
10.1002/ccd.25473
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundRadiation exposure in the pediatric population may increase the risk of future malignancy. Children with congenital heart disease who often undergo repeated catheterizations are at risk. One possible strategy to reduce radiation is to use X-ray Magnetic Resonance Fusion (XMRF) to facilitate cardiac catheterization. MethodsCatheterization data of patients who underwent diagnostic XMRF procedures between January 1, 2009 and February 1, 2012 were reviewed. Cases were matched 1:1 to contemporary controls who did not undergo XMRF based on weight and diagnosis and were compared in radiation exposure, contrast dose, and procedural and anesthesia times. ResultsForty-four matched pairs were included. Baseline demographics were similar in both groups. Patients in the XMRF group had lower indices of radiation exposure measured by fluoroscopy time (14 vs. 16.4 vs. P=0.047), dose-area product from fluoroscopy (513.2 vs. 589.1 mu Gym(2), P=0.042), total dose-area product (625.8 vs. 995.2 mu Gym(2), P=0.027), and total air kerma dose (94.5 vs. 153.8 mGy, P=0.017). There was also a significant reduction in contrast dose (2 vs. 3.3 cc/kg, P <0.001). Procedural time tended to be shorter in the XMRF group but anesthesia time was significantly longer. ConclusionSelect diagnostic cardiac catheterization cases that utilized XMRF used less radiation and contrast than similar cases where XMRF was not used. Future work is needed to determine whether similar benefits can be extended to other types of diagnostic and complex interventional procedures. (c) 2014 Wiley Periodicals, Inc.
引用
收藏
页码:795 / 800
页数:6
相关论文
共 12 条
[1]   Patient-specific dose and radiation risk estimation in pediatric cardiac catheterization [J].
Bacher, K ;
Bogaert, E ;
Lapere, R ;
De Wolf, D ;
Thierens, H .
CIRCULATION, 2005, 111 (01) :83-89
[2]   X-Ray Magnetic Resonance Fusion to Internal Markers and Utility in Congenital Heart Disease Catheterization [J].
Dori, Yoav ;
Sarmiento, Marily ;
Glatz, Andrew C. ;
Gillespie, Matthew J. ;
Jones, Virginia M. ;
Harris, Matthew A. ;
Whitehead, Kevin K. ;
Fogel, Mark A. ;
Rome, Jonathan J. .
CIRCULATION-CARDIOVASCULAR IMAGING, 2011, 4 (04) :415-U115
[3]  
DUCKETT S, 2010, PACING CLIN ELECTROP, V34, P226
[4]   Cardiac three-dimensional magnetic resonance imaging and fluoroscopy merging -: A new approach for electroanatomic mapping to assist catheter ablation [J].
Ector, J ;
De Buck, S ;
Adams, J ;
Dymarkowski, S ;
Bogaert, J ;
Maes, F ;
Heidbüchel, H .
CIRCULATION, 2005, 112 (24) :3769-3776
[5]   Technology preview:: X-ray fused with magnetic resonance during invasive cardiovascular procedures [J].
Gutierrez, Luis F. ;
de Silva, Ranil ;
Ozturk, Cengizhan ;
Sonmez, Merdim ;
Stine, Annette M. ;
Raval, Amish N. ;
Raman, Venkatesh K. ;
Sachdev, Vandana ;
Aviles, Ronnier J. ;
Waclawiw, Myron A. ;
McVeigh, Elliot R. ;
Lederman, Robert J. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2007, 70 (06) :773-782
[6]   Cancer risks following diagnostic and therapeutic radiation exposure in children [J].
Kleinerman, Ruth A. .
PEDIATRIC RADIOLOGY, 2006, 36 (Suppl 2) :121-125
[7]   Cancer following cardiac catheterization in childhood [J].
Modan, B ;
Keinan, L ;
Blumstein, T ;
Sadetzki, S .
INTERNATIONAL JOURNAL OF EPIDEMIOLOGY, 2000, 29 (03) :424-428
[8]   Validation of European System for Cardiac Operative Risk Evaluation (EuroSCORE) in North American cardiac surgery [J].
Nashef, SAM ;
Roques, F ;
Hammill, BG ;
Peterson, ED ;
Michel, P ;
Grover, FL ;
Wyse, RKH ;
Ferguson, TB .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2002, 22 (01) :101-105
[9]   Predictive performance and variability of the cardiac anesthesia risk evaluation score [J].
Ouattara, A ;
Niculescu, M ;
Ghazouani, S ;
Babolian, A ;
Landi, M ;
Lecomte, P ;
Boccara, G ;
Varnous, S ;
Leprince, P ;
Riou, B ;
Coriat, P .
ANESTHESIOLOGY, 2004, 100 (06) :1405-1410
[10]   Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study [J].
Pearce, Mark S. ;
Salotti, Jane A. ;
Little, Mark P. ;
McHugh, Kieran ;
Lee, Choonsik ;
Kim, Kwang Pyo ;
Howe, Nicola L. ;
Ronckers, Cecile M. ;
Rajaraman, Preetha ;
Craft, Alan W. ;
Parker, Louise ;
de Gonzalez, Amy Berrington .
LANCET, 2012, 380 (9840) :499-505