Influence of Grounding Wires on Measured Frequency-Dependent Soil Properties

被引:0
|
作者
Borozdina, Evgeniya [1 ]
Kuklin, Dmitry [1 ]
机构
[1] Russian Acad Sci, Kola Sci Ctr, Northern Energet Res Ctr, Branch Fed Res Ctr, Apatity, Russia
关键词
grounding wire; simulation; finite-difference time-domain method; frequency-dependent soil properties; soil resistivity; complex permittivity; LIGHTNING RESPONSE; FDTD;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Calculations and measurements show that the grounding wires can significantly influence measured frequency-dependent soil properties (resistivity and permittivity). The smaller the distance between the grounding wire and the measurement setup, the larger the measurement error. In order to improve measurement accuracy, one should determine the minimum distance for which the measurement error can be neglected. The work proposes and experimentally validates the simulation model based on the finite-difference time-domain method. The model allows changing the grounding wire position relative to the measurement setup and estimating the measurement error. It has been demonstrated that a distance of about 1.5 m between the wire and the array is sufficient to neglect the measurement error.
引用
收藏
页码:627 / 631
页数:5
相关论文
共 50 条
  • [1] INFLUENCE OF FREQUENCY-DEPENDENT SOIL ELECTRICAL PARAMETERS ON THE GROUNDING RESPONSE TO LIGHTNING
    Pedrosa, Adriana G.
    Schroeder, Marco A. O.
    Alipio, Rafael S.
    Visacro, Silverio
    2010 30TH INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2010,
  • [2] The Impact of Apparent Frequency-Dependent Soil Properties on Electrical Grounding Characteristics
    Kuklin, Dmitry
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2022, 64 (06) : 2122 - 2130
  • [3] Influence of the frequency-dependent characteristics of soil permittivity on the impulse performance of grounding electrode
    Zhu, Shi-yang
    Yuan, Tao
    Deng, Yu-rong
    Zhu, Bin
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2016, 11 (02) : 146 - 151
  • [4] Evaluation of the transmission tower and frequency-dependent soil parameters influence on the grounding potential rise waveforms
    Schroeder, Marco Aurelio O.
    Moura, Rodolfo A. R.
    Assis, Fernando A.
    Paulino, Jose O. S.
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 222
  • [5] A Comparison of Frequency-Dependent Soil Models: Application to the Analysis of Grounding Systems
    Cavka, Damir
    Mora, Nicolas
    Rachidi, Farhad
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2014, 56 (01) : 177 - 187
  • [6] Impulse Efficiency of Grounding Electrodes: Effect of Frequency-Dependent Soil Parameters
    Alipio, Rafael
    Visacro, Silverio
    IEEE TRANSACTIONS ON POWER DELIVERY, 2014, 29 (02) : 716 - 723
  • [7] FREQUENCY-DEPENDENT CHARACTERISTICS OF GROUNDING SYSTEMS
    PAPALEXOPOULOS, AD
    MELIOPOULOS, AP
    IEEE TRANSACTIONS ON POWER DELIVERY, 1987, 2 (04) : 1073 - 1081
  • [8] Depth of Investigation in Measurements of Frequency-Dependent Soil Properties
    Kuklin, Dmitry
    Borozdina, Evgeniya
    2024 INTERNATIONAL SYMPOSIUM AND EXHIBITION ON ELECTROMAGNETIC COMPATIBILITY, EMC EUROPE 2024, 2024, : 407 - 412
  • [9] Analysis of Transient Performance of Grounding System Considering Frequency-Dependent Soil Parameters and Ionization
    Moradi, Mohamad
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2020, 62 (03) : 785 - 797
  • [10] The Response of Grounding Electrodes to Lightning Currents: The Effect of Frequency-Dependent Soil Resistivity and Permittivity
    Visacro, Silverio
    Alipio, Rafael
    Murta Vale, Maria Helena
    Pereira, Clever
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2011, 53 (02) : 401 - 406