Lenticule Thickness Readout for Small Incision Lenticule Extraction Compared to Artemis Three-Dimensional Very High-Frequency Digital Ultrasound Stromal Measurements

被引:55
作者
Reinstein, Dan Z. [1 ,2 ,3 ]
Archer, Timothy J. [1 ]
Gobbe, Marine [1 ]
机构
[1] London Vis Clin, London W1G 7LA, England
[2] Columbia Univ, Dept Ophthalmol, Med Ctr, New York, NY 10027 USA
[3] Ctr Hosp Natl Ophtalmol, Paris, France
关键词
VISUMAX FEMTOSECOND LASER; TENSILE-STRENGTH; VISUAL OUTCOMES; MYOPIC LASIK; ACCURACY; CORNEA; REPRODUCIBILITY; DISPLAY; MODEL;
D O I
10.3928/1081597X-20140416-01
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the accuracy of the lenticule thickness readout for small incision lenticule extraction (SMILE) with the VisuMax femtosecond laser (Carl Zeiss Meditec, Jena, Germany). METHODS: Artemis very high-frequency digital ultrasound (ArcScan, Inc., Morrison, CO) measurements were obtained before and 3 months after SMILE in 70 eyes of 37 patients. The Artemis measured lenticule thickness was calculated as the maximum difference in stromal thickness before and after treatment. Comparative statistics and linear regression analysis were performed between the VisuMax readout lenticule thickness and Artemis measured maximum stromal change. Central epithelial thickness was measured and a similar analysis was performed using corneal thickness. Variability of the data were compared to ablation depths for a matched group of eyes from a previously published LASIK population treated with the MEL80 excimer laser (Carl Zeiss Meditec). RESULTS: The mean maximum myopic meridian treated was -7.81 +/- 2.33 diopters (range: -2.25 to -12.50 diopters). On average, the VisuMax readout lenticule depth was 8.2 +/- 8.0 mu m thicker (range: -8 to + 29 mu m) than the Artemis measured stromal change (P <.001). On average, central epithelial thickness was 15.0 +/- 5.2 mu m thicker (range: 5 to 30 mu m) after the procedure. The VisuMax readout lenticule thickness was 23.2 +/- 10.9 mu m thicker (range: + 5 to + 49 mu m) than the Artemis measured corneal thickness change. The R-2 of 0.868 for the SMILE group was higher than 0.738 for the LASIK group (P=.015). CONCLUSIONS: The accuracy of SMILE lenticule thickness was found to be higher than actual measured stromal thickness change; however, predictability for SMILE lenticule thickness appeared higher than predictability for excimer laser ablation depth. The VisuMax readout lenticule depth was found to be 8 mu m thicker than the achieved stromal change. This can be partly explained by alignment errors between preoperative and postoperative scans. However, this appears to show some biomechanical changes occur after SMILE.
引用
收藏
页码:304 / 309
页数:6
相关论文
共 30 条
[1]   Comparison of laser in situ keratomileusis flaps created by 3 femtosecond lasers and a microkeratome [J].
Ahn, Hyunseok ;
Kim, Jin-Kook ;
Kim, Chang Kook ;
Han, Gyu Heon ;
Seo, Kyoung Yul ;
Kim, Eung Kweon ;
Kim, Tae-im .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (02) :349-357
[2]   Geometrical analysis of the loss of ablation efficiency at non-normal incidence [J].
Arba-Mosquera, Samuel ;
de Ortueta, Diego .
OPTICS EXPRESS, 2008, 16 (06) :3877-3895
[3]   EXCIMER-LASER ABLATION RATE AND CORNEAL HYDRATION [J].
DOUGHERTY, PJ ;
WELLISH, KL ;
MALONEY, RK .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1994, 118 (02) :169-176
[4]   Predictors for the Outcome of Small-incision Lenticule Extraction for Myopia [J].
Hjortdal, Jesper O. ;
Vestergaard, Anders H. ;
Ivarsen, Anders ;
Ragunathan, Suganiah ;
Asp, Sven .
JOURNAL OF REFRACTIVE SURGERY, 2012, 28 (12) :865-871
[5]   Femtosecond laser flap parameters and visual outcomes in laser in situ keratomileusis [J].
Issa, Ammar ;
Al Hassany, Usama .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (04) :665-674
[6]   Reproducibility of LASIK Flap Thickness Using the Zeiss Femtosecond Laser Measured Postoperatively by Optical Coherence Tomography [J].
Ju, Won-Kyung ;
Lee, Jeong-Hye ;
Chung, Tae-Young ;
Chung, Eui-Sang .
JOURNAL OF REFRACTIVE SURGERY, 2011, 27 (02) :106-110
[7]  
Mrochen M, 2001, J REFRACT SURG, V17, pS584
[8]  
Preacher K.J., 2002, Calculation for the test of the difference between two independent correlation coefficients
[9]  
Randleman JB, 2008, J REFRACT SURG, V24, P85
[10]   Probability model of the inaccuracy of residual stromal thickness prediction to reduce the risk of ectasia after LASIK - Part I: Quantifying individual risk [J].
Reinstein, Dan Z. ;
Srivannaboon, Sabong ;
Archer, Timothy J. ;
Silverman, Ronald H. ;
Sutton, Hugo ;
Coleman, D. Jackson .
JOURNAL OF REFRACTIVE SURGERY, 2006, 22 (09) :851-860