摘要
This paper presents the acoustic performance of a novel approach for the passive adaptive control of tonal noise radiated from subsonic fans. Tonal noise originates from non-uniform flow that causes circumferentially varying blade forces and gives rise to a considerably larger radiated dipolar sound at the blade passage frequency (BPF) and its harmonics compared to the tonal noise generated by a uniform flow. The approach presented in this paper uses obstructions in the flow to destructively interfere with the primary tonal noise arising from various flow conditions. The acoustic radiation of the obstructions is first demonstrated experimentally. Indirect on-axis acoustic measurements are used to validate the analytical prediction of the circumferential spectrum of the blade unsteady lift and related indicators generated by the trapezoidal and sinusoidal obstructions presented in Ref. [A. Gerard, A. Berry, P. Masson, Y. Gervais, Modelling of tonal noise control from subsonic axial fans using flow control obstructions, Journal of Sound and Vibration (2008), this issue, doi:10.1016/j.jsv.2008.09.027.] and also by cylindrical obstructions used in the literature. The directivity and sound power attenuation are then given in free field for the control of the BPF tone generated by rotor/outlet guide vane (OGV) interaction and the control of an amplified BPF tone generated by the rotor/OGV interaction with an added triangular obstruction between two outlet guide vanes to enhance the primary non-uniform flow. Global control was demonstrated in free field, attenuation up to 8.4dB of the acoustic power at BPF has been measured. Finally, the aerodynamic performances of the automotive fan used in this study are almost not affected by the presence of the control obstruction. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:8 / 25
页数:18
相关论文
共 14 条
[1]  
ANDERSSON AO, 1996, Patent No. 9509999
[2]  
Farrell K. J., 2002, U.S. Patent, Patent No. [6,375,416, 6375416]
[3]   Application of theoretical modeling to multichannel active control of cooling fan noise [J].
Gee, KL ;
Sommerfeldt, SD .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2004, 115 (01) :228-236
[4]   Evaluation of tonal aeroacoustic sources in subsonic fans using inverse models [J].
Gerard, A. ;
Berry, A. ;
Masson, P. ;
Gervais, Y. .
AIAA JOURNAL, 2007, 45 (01) :98-109
[5]   Control of tonal noise from subsonic axial fan.: Part 1:: reconstruction of aeroacoustic sources from far-field sound pressure [J].
Gérard, A ;
Berry, A ;
Masson, P .
JOURNAL OF SOUND AND VIBRATION, 2005, 288 (4-5) :1049-1075
[6]   Modelling of tonal noise control from subsonic axial fans using flow control obstructions [J].
Gerard, Anthony ;
Berry, Alain ;
Masson, Patrice ;
Gervais, Yves .
JOURNAL OF SOUND AND VIBRATION, 2009, 321 (1-2) :26-44
[7]   Active control of fan-generated tone noise [J].
Gerhold, CH .
AIAA JOURNAL, 1997, 35 (01) :17-22
[8]  
Goldstein ME., 1976, AEROACOUSTICS
[9]   Wake generator control of inlet flow to cancel flow distortion noise [J].
Kota, V. ;
Wright, M. C. M. .
JOURNAL OF SOUND AND VIBRATION, 2006, 295 (1-2) :94-113
[10]  
Lemke O., 2007, FAN NOISE 2007, V2007