Cardiac Output Measurement by Arterial Pressure Waveform Analysis During Optimization of Biventricular Pacing After Cardiac Surgery

被引:2
作者
Booth, Justin H. [1 ]
Quinn, T. Alexander [2 ]
Richmond, Marc E. [3 ]
Cabreriza, Santos E. [1 ]
Weinberg, Alan D. [4 ]
Johnston, Taylor [5 ]
Spotnitz, Henry M. [1 ]
机构
[1] Columbia Univ, Dept Surg, New York, NY USA
[2] Columbia Univ, Dept Biomed Engn, New York, NY USA
[3] Columbia Univ, Dept Pediat, New York, NY USA
[4] Columbia Univ, Dept Biostat, New York, NY USA
[5] Columbia Univ, Dept Anesthesiol, New York, NY USA
关键词
PULSE CONTOUR ANALYSIS; STROKE VOLUME; MAC-BAR; VALIDATION; PULSECO(TM); ISOFLURANE; INDICATOR; INCISION; OVERLOAD; DOPPLER;
D O I
10.1097/MAT.0b013e3181bbafd5
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Biventricular pacing (BiVP) can optimize cardiac output (CO) in patients after cardiac surgery, so devices that calculate continuous CO from arterial pressure may be a useful tool. We investigated PulseCO for measuring CO during optimization by comparison with aortic flow probe measurement. Seven patients in the Biventricular Pacing After Cardiac Surgery (BiPACS) trial were studied. Before weaning from cardiopulmonary bypass, BiVP was initiated. After bypass, CO was optimized by varying atrioventricular pacing delay, ventricular site, and interventricular pacing delay with a randomized protocol. Continuous CO was measured by PulseCO and aortic flow probe. Reliability was estimated by Fleiss method and agreement assessed by Bland-Altman analysis. Compared with flow probe, PulseCO reliably measured changes in CO (intraclass correlation coefficient = 0.90) but underestimated the change (-4% +/- 17%). In contrast, changes in mean arterial pressure did not reflect changes in CO (intraclass correlation coefficient = 0.02). Thus, PulseCO can measure continuous CO in open-chest patients after cardiac surgery, whereas underestimating changes occurring across 10-second pacemaker changes. Further studies in the closed chest are indicated. ASAIO Journal 2009; 55:587-591.
引用
收藏
页码:587 / 591
页数:5
相关论文
共 32 条
[1]   Optimized biventricular pacing in atrioventricular block after cardiac surgery [J].
Berberian, G ;
Quinn, TA ;
Kanter, JP ;
Curtis, LJ ;
Cabreriza, SE ;
Weinberg, AD ;
Spotnitz, HM .
ANNALS OF THORACIC SURGERY, 2005, 80 (03) :870-875
[2]   Validation study of PulseCO system for continuous cardiac output measurement [J].
Berberian, G ;
Quinn, TA ;
Vigilance, DW ;
Park, DY ;
Cabreriza, SE ;
Curtis, LJ ;
Spotnitz, HM .
ASAIO JOURNAL, 2005, 51 (01) :37-40
[3]   Optimized perioperative biventricular pacing in setting of right heart failure [J].
Berberian, G ;
Kanter, JP ;
Quinn, TA ;
Spotnitz, HM .
EUROPACE, 2005, 7 (04) :385-387
[4]   Left ventricular pacing site-timing optimization during biventricular pacing using a multi-electrode patch [J].
Berberian, George ;
Cabreriza, Santos E. ;
Quinn, Thomas Alexander ;
Garofalo, Cara A. ;
Spotnitz, Henry M. .
ANNALS OF THORACIC SURGERY, 2006, 82 (06) :2292-2294
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   Continuous cardiac output monitoring via arterial pressure waveform analysis following severe hemorrhagic shock in dogs [J].
Cooper, Edward S. ;
Muir, William W. .
CRITICAL CARE MEDICINE, 2007, 35 (07) :1724-1729
[7]   Fentanyl augments the blockade of the sympathetic response to incision (MAC-BAR) produced by desflurane and isoflurane - Desflurane and isoflurane MAC-BAR without and with fentanyl [J].
Daniel, M ;
Weiskopf, RB ;
Noorani, M ;
Eger, EI .
ANESTHESIOLOGY, 1998, 88 (01) :43-49
[8]   An evaluation of cardiac output by five arterial pulse contour techniques during cardiac surgery [J].
de Wilde, R. B. P. ;
Schreuder, J. J. ;
van den Berg, P. C. M. ;
Jansen, J. R. C. .
ANAESTHESIA, 2007, 62 (08) :760-768
[9]   Validation study of a new transit time ultrasonic flow probe for continuous great vessel measurements [J].
Dean, DA ;
Jia, CX ;
Cabreriza, SE ;
DAlessandro, DA ;
Dickstein, ML ;
Sardo, MJ ;
Chalik, N ;
Spotnitz, HM .
ASAIO JOURNAL, 1996, 42 (05) :M671-M676
[10]   Impact of dopamine or dobutamine infusions on cardiovascular variables after rapid blood loss and volume replacement during isoflurane-induced anesthesia in dogs [J].
Dyson, DH ;
Sinclair, MD .
AMERICAN JOURNAL OF VETERINARY RESEARCH, 2006, 67 (07) :1121-1130