Three-dimensional T1-weighted gradient echo is a suitable alternative to two-dimensional T1-weighted spin echo for imaging the canine brain

被引:4
|
作者
Fleming, Kathryn L. [1 ]
Maddox, Thomas W. [1 ]
Warren-Smith, Christopher M. R. [2 ]
机构
[1] Univ Liverpool, Sch Vet Sci, Leahurst Campus, Neston, England
[2] Univ Bristol, Sch Clin Vet Sci, Bristol, Avon, England
关键词
intracranial; isotropic; magnetic resonance imaging; MRI; volumetric; MP-RAGE; RESONANCE; DISEASE; LESIONS; MRI; RESOLUTION; TUMORS; DOGS;
D O I
10.1111/vru.12774
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Volumetric imaging (VOL), a three-dimensional magnetic resonance imaging (MRI) technique, has been described in the literature for evaluation of the human brain. It offers several advantages over conventional two-dimensional (2D) spin echo (SE), allowing rapid, whole-brain, isotropic imaging with submillimeter voxels. This retrospective, observational study compares the use of 2D T1-weighted SE (T1W SE), with T1W VOL, for the evaluation of dogs with clinical signs of intracranial disease. Brain MRI images from 160 dogs who had T1W SE and T1W VOL sequences acquired pre- and postcontrast, were reviewed for presence and characteristics of intracranial lesions. Twenty-nine of 160 patients were found to have intracranial lesions, all visible on both sequences. Significantly better grey-white matter (GWM) differentiation was identified with T1W VOL (P < .001), with fair agreement between the two sequences (weighted kappa = 0.35). Excluding a mild reduction in lesion intensity in three dogs precontrast on the T1W VOL images compared to T1W SE, and meningeal enhancement noted on the T1W VOL images in one dog, not identified on T1W SE, there was otherwise complete agreement between the two sequences. The T1W VOL sequence provided equivalent lesion evaluation and significantly improved GWM differentiation. Images acquired were of comparable diagnostic quality to those produced using a conventional T1W SE technique, for assessment of lesion appearance, number, location, mass effect, and postcontrast enhancement. T1W VOL, therefore, provides a suitable alternative T1W sequence for canine brain evaluation and can facilitate a reduction in total image acquisition time.
引用
收藏
页码:543 / 551
页数:9
相关论文
共 50 条
  • [21] Comparison of conventional spin echo and gradient echo T1-weighted sequences in detection of focal pancreatic lesions
    Gallix, BP
    Bret, PM
    Atri, M
    Lecesne, R
    Reinhold, C
    RADIOLOGY, 1997, 205 : 622 - 622
  • [22] Three-dimensional isotropic fast spin-echo MR lymphangiography of T1-weighted and intermediate-weighted pulse sequences in patients with lymphoedema
    Jeon, J. Y.
    Lee, S. H.
    Shin, M. J.
    Chung, H. W.
    Lee, M. H.
    CLINICAL RADIOLOGY, 2016, 71 (01) : E56 - E63
  • [23] A T1-weighted rapid three-dimensional gradient-echo technique (MP-RAGE) in preoperative MRI of intracranial tumours
    Fellner, F
    Holl, K
    Held, P
    Fellner, C
    Schmitt, R
    BohmJurkovic, H
    NEURORADIOLOGY, 1996, 38 (03) : 199 - 206
  • [24] THEORETICAL-ANALYSIS OF GADOPENTETATE DIMEGLUMINE ENHANCEMENT IN T1-WEIGHTED IMAGING OF THE BRAIN - COMPARISON OF 2-DIMENSIONAL SPIN-ECHO AND 3-DIMENSIONAL GRADIENT-ECHO SEQUENCES
    MUGLER, JP
    BROOKEMAN, JR
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (05): : 761 - 769
  • [25] Comparison of contrast-enhanced T1-weighted FLAIR with BLADE, and spin-echo T1-weighted sequences in intracranial MRI
    Alkan, Oezlem
    Kizilkilic, Osman
    Yildirim, Tuelin
    Alibek, Sedat
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2009, 15 (02): : 75 - 80
  • [26] Comparison of T1-weighted turbo spin echo and out-of-phase T1-weighted gradient echo Dixon MRI for the assessment of intra-medullary length of appendicular bone tumours
    Saifuddin, A.
    Santiago, R.
    van Vucht, N.
    Pressney, I.
    SKELETAL RADIOLOGY, 2021, 50 (05) : 993 - 1005
  • [27] Comparison of T1-weighted turbo spin echo and out-of-phase T1-weighted gradient echo Dixon MRI for the assessment of intra-medullary length of appendicular bone tumours
    A. Saifuddin
    R. Santiago
    N. van Vucht
    I. Pressney
    Skeletal Radiology, 2021, 50 : 993 - 1005
  • [28] Usefulness of T1-weighted image with fast inversion recovery technique in intracranial lesions - Comparison with T1-weighted spin echo image
    Lee, JK
    Choi, HY
    Lee, SW
    Baek, SY
    Kim, HY
    CLINICAL IMAGING, 2000, 24 (05) : 263 - 269
  • [29] Correction of intensity nonuniformity in spin-echo T1-weighted images
    Collewet, G
    Davenel, A
    Toussaint, C
    Akoka, S
    MAGNETIC RESONANCE IMAGING, 2002, 20 (04) : 365 - 373
  • [30] Black blood MR angiography using multislab three-dimensional T1-weighted turbo spin-echo technique: Imaging of intracranial circulation
    Melhem, ER
    Jara, H
    Yucel, EK
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (05) : 1418 - 1420