Determination of triazine herbicides by capillary gas chromatography with large-volume on-column injection

被引:18
作者
Beltran, J
Lopez, FJ
Forcada, M
Hernandez, F
机构
[1] Analytical Chemistry, Department of Experimental Sciences, University Jaume I, 12080, Castellón
关键词
liquid-liquid micro-extraction; large-volume injection gas chromatography; groundwater samples; pesticide residues; LARGE-SAMPLE VOLUMES; ATOMIC-EMISSION DETECTION; WATER ANALYSIS; SPLITLESS INJECTION; LIQUID-EXTRACTION; ONLINE; PESTICIDES;
D O I
10.1007/BF02466394
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper describes a study of the potential of large-volume on-column injection for the determination of triazine herbicides in clean water samples (groundwater). The sensitivity of chromatographic determination has been increased by two orders of magnitude by injection of up to 200 mu L of pesticide solutions and nitrogen-phosphorus detection. Analytical characteristics expressed as precision, linear range and limit of detection have been determined, the results indicating adequate analytical performance and the ruggedness of the injection technique. As an application, gas chromatography with large-volume on-column injection and nitrogen-phosphorus detection was combined with offline liquid-liquid micro-extraction with hexane (1 mt water/1 mt hexane). The procedure was applied to spiked groundwater samples at two concentration levels (1 and 10 mu g L-1) with good recoveries (between 81 and 103 %, except for deethylatrazine) and repeatability (better than 15 % at the 1 mu g L-1 level). Limits of detection of the triazine herbicides studied ranged from 0.08 to 0.16 mu g L-1.
引用
收藏
页码:274 / 278
页数:5
相关论文
共 13 条
[1]  
BRINKMAN UAT, 1995, CHEM ANAL-WARSAW, V40, P495
[2]  
GOOSENS EC, 1995, HRC-J HIGH RES CHROM, V18, P38
[3]   ON-COLUMN INJECTION OF LARGE SAMPLE VOLUMES USING THE RETENTION GAP TECHNIQUE IN CAPILLARY GAS-CHROMATOGRAPHY [J].
GROB, K ;
KARRER, G ;
RIEKKOLA, ML .
JOURNAL OF CHROMATOGRAPHY, 1985, 334 (02) :129-155
[4]  
GROB K, 1994, HRC-J HIGH RES CHROM, V17, P792
[6]  
Mol HGJ, 1995, J HIGH RES CHROMATOG, V18, P124
[7]  
MOL HGJ, 1995, J HIGH RES CHROMATOG, V18, P19
[8]   GAS-CHROMATOGRAPHIC WATER ANALYSIS BY DIRECT-INJECTION OF LARGE-SAMPLE VOLUMES IN AN ADSORBENT-PACKED PTV INJECTOR [J].
MULLER, S ;
EFER, J ;
ENGEWALD, W .
CHROMATOGRAPHIA, 1994, 38 (11-12) :694-700
[9]   GC INSTRUMENTATION FOR ON-COLUMN INJECTION OF LARGE VOLUMES - AUTOMATED OPTIMIZATION OF CONDITIONS [J].
MUNARI, F ;
COLOMBO, PA ;
MAGNI, P ;
ZILIOLI, G ;
TRESTIANU, S ;
GROB, K .
JOURNAL OF MICROCOLUMN SEPARATIONS, 1995, 7 (04) :403-409
[10]   LARGE-VOLUME INJECTIONS IN GAS-CHROMATOGRAPHY ATOMIC-EMISSION DETECTION - AN APPROACH FOR TRACE-LEVEL DETECTION IN WATER ANALYSIS [J].
RINKEMA, FD ;
LOUTER, AJH ;
BRINKMAN, UAT .
JOURNAL OF CHROMATOGRAPHY A, 1994, 678 (02) :289-297