Plate load tests for investigation of the load-settlement behaviour of shallow foundation on bitumen-coated geogrid reinforced soil bed

被引:14
作者
Akbar, Asif [1 ]
Bhat, Javed Ahmad [1 ]
Mir, Bashir Ahmed [1 ]
机构
[1] Natl Inst Technol Srinagar, Dept Civil Engn, Srinagar 190006, Jammu & Kashmir, India
关键词
Soft soil; Geosynthetics; Reinforcement; Settlement; Foundation bed; Bearing capacity ratio;
D O I
10.1007/s41062-020-00397-6
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The paucity of the desirable construction land in India due to day by day increasing population has put grand challenges in front of engineers. So they accentuated the use of undesirable construction land which is having low bearing capacity and large plastic deformation. Among several ground improvement techniques, geosynthetic reinforced soil system is widely adopted as foundation medium keeping in view its economical benefits and sustainable development. Therefore, the main objective of this study was to investigate the effect of a bitumen-coated geogrid reinforcement on the bearing capacity ratio of a shallow foundation in a two-layer silty clay foundation bed. The top layer of locally available silty clay was compacted at OMC (19%) with 0.95MDD, and the bottom soft layer was compacted at dry side of OMC (15%) with 0.75MDD. Various model plate load tests were carried out using a square footing of size 200 mm and thickness 25 mm over a silty clay bed reinforced with bitumen-coated geogrid BX-40, BX-60 and BX-80 having different ultimate strengths in a test tank of dimensions 1000x1000x1000 mm. The effect on bearing capacity and plastic deformation due to varying end conditions of geogrid reinforcement was also investigated. The other various parameters investigated were the top spacing ratio, width of the geogrid, no. of layers of the geogrid and the stress distribution in various reinforcement layouts. The bearing capacity ratio of reinforced clay was found to be increased by 20-55% than unreinforced clay. The settlement reduction factor of reinforced clay was increased by 9-40% than unreinforced clay. Also the vertical stresses were reduced up to 20% in reinforced clay.
引用
收藏
页数:17
相关论文
共 106 条
[1]  
Abdelhadi M., 2013, CONT ENG SCI, V6, P213, DOI [10.12988/ces.2013.3529, DOI 10.12988/CES.2013.3529]
[2]   Experimental and PIV evaluation of grain size and distribution on soil-geogrid interactions in pullout test [J].
Abdi, M. R. ;
Mirzaeifar, H. .
SOILS AND FOUNDATIONS, 2017, 57 (06) :1045-1058
[3]  
Abu-Farsakh M, 2008, GEOTECH TEST J, V31, P413
[4]   An experimental evaluation of the behavior of footings on geosynthetic-reinforced sand [J].
Abu-Farsakh, Murad ;
Chen, Qiming ;
Sharma, Radhey .
SOILS AND FOUNDATIONS, 2013, 53 (02) :335-348
[5]   Large model spread footing load tests on geosynthetic reinforced soil foundations [J].
Adams, MT ;
Collin, JG .
JOURNAL OF GEOTECHNICAL AND GEOENVIRONMENTAL ENGINEERING, 1997, 123 (01) :66-72
[6]  
Akinmusuru JO, 1981, J GEOTECH GEOENVIRON, V107
[7]   Settlement and bearing capacity of geogrid-reinforced sand over collapsible soil [J].
Alawaji, HA .
GEOTEXTILES AND GEOMEMBRANES, 2001, 19 (02) :75-88
[8]  
[Anonymous], 1973, IS272010
[9]  
[Anonymous], 1977, IS272040
[10]  
[Anonymous], 1970, IS1498